Pre-Service Check List

1
Call up the last fault stored by the
Bosch Heatronic, Service Function .0,
(see page 34).
2
Check ionisation current, Service
Function 3.3, (see page 34).
3
Perform visual check of air/flue duct.
4
Check gas supply pressure
(see page 29).
5
Test combustion air/flue gas
(see page 31).
6
Check CO
setting for min./
2
max. (gas/air ratio)
(see page 29).
7
Check gas and water systems for
leaks (see page 15).
8
Check heat exchanger
(see page 34).
9
Check burner (see page 35).
10 Clean condensation trap
(see page 35).
11 Check charge pressure of
expansion vessel matches
static head of heating system.
12 Check central heating system
pressure.
13 Check electrical wiring for damage.
14 Check heating programmer settings.
15 Check appliances that are part of
the heating system
Table 14