Unless otherwise noted, references to brand names, product names, or trademarks constitute the intellectual property of the owner thereof. Subject to your right to use the unit, Compac does not convey any right, title, or interest in its intellectual property, including and without limitation, its patents, copyrights, and know-how.
Nozzle 8 Mounting Rear of Unit Holder Holes Ø20 Front of Unit Standard 3 bolt Outlet triangular flange Footprint Plan View L40P L80P G:\Masters\Installation Sheets\Laser\L40P L80P Installation Sheet.doc Page 4 of 16...
This is not a recommended alternative to wearing an anti-static wrist strap. Note: Compac Industries Limited reserves the right to refuse to accept any circuit boards returned, if proper anti-static precautions have not been taken.
These switches are set in the factory and should not be changed. If they are accidentally changed these are the correct settings for Laser Pump applications. Note: They are 3 position switches Pump (Motor triac fitted) Centre G:\Masters\Installation Sheets\Laser\L40P L80P Installation Sheet.doc Page 7 of 16...
Note: Comms cable is not intrinsically safe. Note: Pump comm’s connect to pump controller such as DCA, Communicator Controller etc. (option). When replacing the lid of the flameproof enclosure, ensure the sealing O ring is in place. G:\Masters\Installation Sheets\Laser\L40P L80P Installation Sheet.doc Page 8 of 16...
Configuration Code 10.1 The configuration code has been set at Compac and should not be changed In the event of it being lost and having to be re-entered the configuration is written on the yellow label on the C4000 processor board cover.
J15: Not used Side A J4: Input from KG Meter J10: Totes J16: Not used Side B J5 : Not Used J11: Buzzer J17 Backlighting G:\Masters\Installation Sheets\Laser\L40P L80P Installation Sheet.doc J6 Not used J12 Nozzle Switches Page 10 of 16...
Existing Factor 10.00 Existing Factor Change the existing 'K' Factor to this new value. Sealing the K-Factor switch 11.2 After calibration the K-factor switch should be sealed as shown G:\Masters\Installation Sheets\Laser\L40P L80P Installation Sheet.doc Page 11 of 16...
Err 9 Faulty or disconnected meter encoder. Check that encoder is plugged in. Replace encoder PCB on meter Err 10 Configuration Lost Reconfigure C4000 refer to C4000 manual G:\Masters\Installation Sheets\Laser\L40P L80P Installation Sheet.doc Page 12 of 16...
3/4 HP Electric Motor F-MOTOR-230-550W Pump Unit (incl inlet and outlet gaskets) F-PUMP-ZYB-50-40 (for 40lpm only) F-PUMP-ZYB-50 (for 80lpm only) C4000 Power Supply (does not include box) F-CP-C4PWR-ASSEM Motor Triac F-AT-BTA40-RD91 G:\Masters\Installation Sheets\Laser\L40P L80P Installation Sheet.doc Page 14 of 16...
Revision History Previous revision date Summary of changes 20/05/2010 Added Conditions of Use and 12/06/2012 Updated pipe installation, generator power & hose breakaway instructions. 19/06/2013 Updated wiring info & spare parts G:\Masters\Installation Sheets\Laser\L40P L80P Installation Sheet.doc Page 16 of 16...
Need help?
Do you have a question about the L40P and is the answer not in the manual?