14kV/06mA High Voltage Power Supply for Electrostatic Air Cleaner
1. Overview
The 14kVDC/06mA HV power supply is an OEM product and comes without AC
power ON/OFF controls and safety interlocks. It is system integrator
responsibility to assure that all national, state and local electrical safety codes
are followed.
1.1 Principle of operation
The block diagram of HV Power Supply is shown in Fig. 1
The HV Power supply has built in universal input, power factor corrected AC/DC power
converter, which produces 450VDC for the resonant DC/DC HV power converter. The
Resonant Power Converter drives the HV step up transformer, which delivers up to
1.5kV RMS to the HV multiplier. The 4 stage HV multiplier produces up to 14kVDC at
the output (Ionizer) and 7kVDC at the output of second stage (collector).
This PS has capabilities to deliver up to 6mA DC current at 14KVDC to 2 X 24" Linear
cells.
The resonant power converter is over voltage, over current, overpower protected
including continuous output short circuit condition.
Operating HV and output current limit are set manually however Intelligent Controller
has the capability to perform the following functions:
1. Monitors internal ambient temperature and turns HV converter off if temperature
is outside operating limits.
2. Monitors HV and output current
3. Maintain the best performance and minimize load cell arcing
4. Reports HV converter status using LED Lamps and optional serial messages on
RS-485 port or Modbus.
Operating HV, Current, Temperature, number of hours of operation, error codes
can be monitored on optional RS-485 output or Modus output terminals.
AHVPS714-06-MV-PCB
Specifications and operating manual
1
Rev. 1 03/12/2020

Advertisement

loading
Need help?

Need help?

Do you have a question about the AHVPS714-06-MV-PCB and is the answer not in the manual?

Questions and answers

Summary of Contents for Allanson AHVPS714-06-MV-PCB

  • Page 1 AHVPS714-06-MV-PCB 14kV/06mA High Voltage Power Supply for Electrostatic Air Cleaner Specifications and operating manual 1. Overview The 14kVDC/06mA HV power supply is an OEM product and comes without AC power ON/OFF controls and safety interlocks. It is system integrator responsibility to assure that all national, state and local electrical safety codes are followed.
  • Page 2 Additional HV and current can be monitored on scaled down analog output. I Monitor – 100mV per 1mA V monitor – 100mV per 1KV 5. Keeps track of operating hours 6. Connect to Remote LED diagnostic PCB. Status LED functionality and simplified flowchart are shown in Appendix A. 2.0 The HVPS has 3 distinct modes of operation: Voltage Source Mode Current Source Mode...
  • Page 3 was operating with 6mA current, but HV increased to 12.5kV to maintain 6mA current. 2.3 Burns-In Mode. In normal operation the HVPS is exposed to occasional overload conditions caused by arcing in the load cells. The HVPS monitors the rate and duration of overload conditions and shut down if overload condition persists.
  • Page 4 Universal Input 120 - 240 VAC POWER FACTOR POWER TRANSFORMER CORRECTOR Burn in MODULE On/ off 14kV HV MULTIPLIER GOOD RELAY CURRENT LIMIT RESONANT POWER ADJUST CONVERTER HIGH VOLTAGE ADJUST CURRENT FEEDBACK V MONITOR VOLTAGE FEEDBACK I MONITOR INTELLIGENT CONTROLLER ISOLATED STATUS LEDs RS-485 or Modbus...
  • Page 5: Field Wiring Connections

    3.0 Installation and safety The HV Power Supply must be mounted indoors, protected from weather Elements, in a location easily accessible by operating service personnel. The HV Power Supply is equipped with universal input; power factor corrected (PFC) AC/DC power supply and can operate from 120VAC or 240VAC power lines. The maximum current draw is 0.85 Amp from 120 VAC line and 0.42 Amp from 240VAC line.
  • Page 6 5. Start - up WARNING!!! HIGH VOLTAGE - RISK OF ELECTRIC SHOCK Check load cells specifications and number of cells connected before adjusting the HV and current limits. Instructions below are to operate the HV Power supply in Voltage Source Mode. Consult factory if Current Source Mode is preferred. 1.
  • Page 7 Air cleaner 14 kV HV power supply Connections, indicators and controls CONNECTION RESONANT Burn in Burn in POWER On/ off On/ off CONVERTER HV TRANSFORMER Min. Max. HV ADJUST Min. Max. HV ON CURRENT HV GND LIMIT ADJUST HV MULTIPLIER POWER ON FAULT 14KV...
  • Page 8: Specifications

    6. Specifications 1. Power Input : Universal voltage input 120 – 240VAC a. Voltage: b. Current: 0.85A @ 120VAC, 0.42 Amp at 240VAC c. Frequency: 50/60HZ d. Power: < 100W e. Power factor : > 0.90 Operating efficiency: 82% typical HV Output : a.
  • Page 9 restarts, HV shuts down for 1 min, Fault Counter # 2 is incremented, and Fault Counter # 1 is cleared. This process may repeat 3 times (until Fault Counter 2 content exceeds 3) and then the HV is turned off permanently. So, the unit allows 5 x 10 = 30 faults with 2 sec recovery time after each fault and additional 1 min recovery after every 10 faults.
  • Page 10 8.0 Connectivity a. Inputs: 120V to 240VAC, Live and Neutral on terminal strip, Earth Ground, #6 Lug on chassis b. OUTPUTS: Ionizer Voltage, Collector Voltage - # 10 Lugs on # 10 studs. High Voltage Return - #6 Lug on chassis 250VAC/10Amp dry contacts to indicate HV GOOD condition Isolated RS-485 or Modbus port c.
  • Page 11: Green Led

    10.0 Agency Approvals rUL, or ETL, optional Manufacturer’s Marking: 11.0 P/N, Date code, serial # Appendix A GREEN LED YELLOW System BLUE LED - - AC Supply RED LED LED HV Relay - Dry Status HV Good, is ON FAULT Contact NO System ON - dry...
  • Page 12 RS-485 Serial port protocol or Modbus protocol RS-485 / Modbus is available on J12 terminal block J12-1 RS-485 NON_INV (A) J12-2 J12-3 RS-485 INV (B) Data Format. Voltage [kVx10] Current [mAx10] Temp [C] Hrs of operation Fault Fault codes: No Fault Over voltage Over current Overload (arcing)