EVGA Z790 DARK K|NGP|N (121-RL-E799)
Repairing an array within IOMSM
This section of the guide will illustrate how to repair a degraded array from within the
IOMSM. For purposes of this guide, we will repair a degraded RAID1 array using a
third drive plugged into the controller, but not currently in use.
Below, you can see a degraded array, and one of its drives reported as unknown/failed.
The data on the other drive is still intact, but the fault tolerance is offline due to the
unknown/failed drive. The IOMSM also shows several warnings, including the "!" for
"Status," an outlined box to bring attention to the degraded array, and the listing for the
unknown hard disk, which also states 0 bytes – a further indicator of a faulty drive.