4.6.4 Fine search ................................... 19 4.6.5 Pinpointing ................................... 20 4.6.6 Multiple burials | MARK function ..........................20 PIEPS PRO BT additional features ........................... 21 4.7.1 Vibra support ................................21 4.7.2 Extended group check & pro-mode .......................... 21 4.7.3 Mark range settings ..............................21 4.7.4 Inclinometer .................................
The following procedures and tips relate only to special usage in conjunction with the PIEPS beacon. The basic line of action in an emergency – as explained in specialist publications and material from avalanche courses – must be followed.
1.1 MARKINGS In accordance with applicable regulations, the following marks may be found on the PIEPS beacon or/and on the packaging: CE mark of conformity: indicating the fulfillment of relevant EU directives. See Chapter 7. Conformity. UKCA mark of conformity indicates fulfillment of relevant UK directives. See Chapter 7.
Any other use requires the written consent of Pieps GmbH. Improper use can put individuals at risk and result in the device being damaged. The PIEPS beacon is not an automatically functioning device with partly automated functionalities – for this reason, the PIEPS beacon may only be commissioned after having read and understood the documentation.
1.7 ESSENTIALS The PIEPS beacon meets the current state of technology and the applicable health and safety regulations. However, incorrect operation or misuse can give rise to hazards for: • the life and health of the users or third parties, •...
It is forbidden to change the PIEPS beacon without the written permission of Pieps GmbH. • Do not attempt to repair damage or malfunctions without authorization. Instead, contact our support, who will tell how to proceed. The PIEPS beacon must not be used until the damage/malfunction has been repaired. •...
Page 8
Bluetooth mode in avalanche terrain! Risk of device loss during slope angle measurement DANGER Although the PIEPS PRO BT keeps transmitting while the inclinometer is active, the function should only be used for training reasons. Never use the inclinometer function in avalanche terrain! Risk of battery explosion due to improper battery types or damaged batteries.
(2P) Analog mode* (2G) Number of burials (1-3) (2Q) Meter symbol for SCAN /analog (2H) Number of burials (4 or mode* more) * PIEPS PRO BT only Manual PIEPS PRO BT/POWDER BT | Firmware v3.0 | 02/2023 9 / 28...
4.2 CARRYING SYSTEM PIEPS recommends using the included carrying system (3A). In order to protect the beacon’s display, carry the beacon with its display facing inwards (3B). The transmit control LED (1G) is visible in the pouch´s window (3C). The carrying system must always be worn under at least one layer of clothing.
Page 11
Send-Vibra Additionally, the PIEPS PRO BT provides haptic send mode confirmation (10x vibration). This feature is enabled by default and can be disabled in the PIEPS APP device manager. Send Search Move the slider lock (1C) to the left and the slider (1B) upwards in the position SEARCH.
4.4 GROUP CHECK The PIEPS PRO BT/POWDER BT provides the option for a group check. This does not replace the Mode Check, but is a useful feature, to ensure that your groups’ transceivers are sending correctly. In group check mode the receiving range is limited to 1 m.
Page 13
Group check Pro-Mode The PIEPS PRO BT additionally provides a pro-mode. The pro-mode allows a transmit check as well as a receive check without exiting the group check mode. By default, it is disabled and can be enabled in the PIEPS APP device manager.
At beacons with software version 1.1 or lower the PIEPS iPROBE support is activated automatically. • At beacons with software version 2.0 or higher the PIEPS iPROBE support is disabled by default and can be enabled in the PIEPS APP device manager.
Page 15
1:30 min 2:00 min To switch the PIEPS PRO BT/POWDER BT back into search-mode: Move the slider (1B) downwards, until it locks in the position SEND. Move the slider lock (1C) to the left and the slider (1B) upwards in the position SEARCH.
(4) Systematic digging (5) First Aid (6) Rescue SIGNAL COARSE SEARCH FINE PINPOINTING SEARCH Point of impact Point of disappearance Primary Result Accuracy Search Speed Search area Manual PIEPS PRO BT/POWDER BT | Firmware v3.0 | 02/2023 16 / 28...
50cm (20") from all electronic, magnetic, and metallic sources of interference. The PIEPS beacon has a circular receiving range that allows a correct indication of direction and distance from the point of initial signal detection – a specific method such as turning/rotating is not necessary.
Page 18
Vibra on initial signal detection The PIEPS PRO BT provides additional haptic support by vibration on initial signal detection. This lets rescuers focus on the visual surface search during the signal search. Manual PIEPS PRO BT/POWDER BT | Firmware v3.0 | 02/2023...
X axis. Always move past the point of the lowest distance to verify the distance tendency. Mark the point of the lowest distance reading and start pinpointing. Manual PIEPS PRO BT/POWDER BT | Firmware v3.0 | 02/2023 19 / 28...
Communicate a hit clearly to companions. Leave the probe stuck for shoveling guidance. NOTICE The PIEPS iPROBE supports perfectly through an optical and acoustic hit indication within 50cm to the burial. 4.6.6 Multiple burials | MARK function A multiple burial is indicated clearly on the display by the number of small human figures (2G, 2H).
See chapter 4.4. 4.7.3 Mark range settings In the PIEPS APP device manager the mark range can be changed from 5 m (default) to 20 m or to max. range. 4.7.4 Inclinometer You can use the integrated three dimensional inclinometer to quickly check the gradient: •...
The Regular SCAN provides a rough overview about the burial situation by indicating the number of victims within certain distance ranges. This is the default setting. The Detailed SCAN shows direction and distance for each victim and allows selecting a victim. The setting can be changed in the PIEPS APP device manager. Regular SCAN Press the button SCAN (1E) while in search mode.
4.7.8 TX600 mode The TX600 mode allows detecting the PIEPS TX600 – this is a mini transmitter for dogs/equipment that works with 456 kHz. Start TX600 mode: Press the buttons MARK (1D) and SCAN (1E) simultaneously for 3 seconds while in search mode.
Bluetooth® and the PIEPS APP allow a straightforward device management (e.g. software update, device configuration) and additionally provide a handy training mode. Get the PIEPS APP (Android Play Store, iOS App Store), connect your PIEPS beacon and take advantage of all features!
In case of a permanent error take the device to your possible. The avalanche beacon function is retailer. working. Is not checked during the self-check, occurs only during Bluetooth activation. Manual PIEPS PRO BT/POWDER BT | Firmware v3.0 | 02/2023 25 / 28...
Risk of explosion from incorrectly used batteries. DANGER Risk of incorrect battery capacity indication. Only use batteries of type “Alkaline (AAA) LR03 1.5 V“ or “Lithium (AAA) FR03 1.5V“! The use of Lithium batteries must be confirmed in the PIEPS APP! Battery lifetime Alkaline Lithium...
7. CONFORMITY EUROPE Hereby, Pieps GmbH declares that the radio equipment type PIEPS PRO BT/POWDER BT is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.pieps.com/conformity...
Page 28
RSS-102 of the IC radio frequency (RF) Exposure rules. This equipment has very low levels of RF energy that are deemed to comply without testing of specific absorption ratio (SAR). Manual PIEPS PRO BT/POWDER BT | Firmware v3.0 | 02/2023 28 / 28...
Need help?
Do you have a question about the PRO BT and is the answer not in the manual?
Questions and answers