Mounting Installation Plate
Ensure that the wall is strong enough to withstand the weight
of the unit. Otherwise, it is necessary to reinforce the wall
with plates, beams or pillars.
Use the level gauge for horizontal mounting, and fix it with
5 suitable screws for FTXS 25/35 and 7 suitable screws for
FTXS 50/60.
In case the rear piping draws out, drill a hole 65mm in
diameter with a cone drill, slightly lower on the outside wall
(see figure).
25/35
50/60
Mounting plate fixing screw
Recommended Mounting Plate Retention Spots And
Dimensions
25/35
Recommended mounting plate retention spots
(5 spots in all)
104
153
55
207
52
Liquid pipe end Gas pipe end
50/60
Recommended mounting plate retention spots
(7 spots in all)
190
Liquid pipe end
45
91
580
45
1065
Hole With Cone Drill
Inside
Wall embedded pipe
(Field supply)
Wall hole cover
(Field supply)
Mounting plate
Mounting plate
fixing screw
Mounting plate
141
Through the
wall hole
Ø 65mm
Drain hose
position
181
56
800
All dimensions are in mm
173
Through the
wall hole
Ø 65mm
Drain hose
Gas pipe end
219
48
position
All dimensions are in mm
Outside
Caulking
Ø 65
Wall embedded pipe
(Field supply)
Mount The Unit Onto The Installation Plate
Hook the indoor unit onto the upper portion of the installation
plate (Engage the two hooks at the rear top of the indoor unit
with the upper edge of the installation plate). Ensure that the
hooks are properly seated on the installation plate by moving
it to the left and right.
How To Attach The Indoor Unit
Hook the claws of the bottom frame to the mounting plate.
How To Remove The Indoor Unit
Push up the marked area (at the lower part of the front
grille) to release the claws.
Front grille
Hand indoor unit's hook here.
When stripping the ends
of interconnecting wires in
advance, bind right ends of
wires with insulating tape.
Water Drainage Piping
The indoor drain pipe must be in a downward gradient for
smooth drainage. Avoid situations that are likely to cause
water to leak.
Water Drainage
Water
leaking
Correct
Wrong
! CAUTION
• Do not install the unit at altitude over 2000m for both
indoor & outdoor.
1-8
Mounting plate
Clip
Bottom frame
Mark (Rear side)
Mounting plate
Interconnecting
wires
Wire guide
Water
retention
Water
Water
leaking
leaking
Wrong
Wrong
End
dipped
into
water
Drain