Possible cause
Connected device is not supported (port
LED lights up red)
Driver error (port LED flashes red)
Overcurrent or connection error (port LED
flashes red quickly)

11.4 GRIPINK Controller reports an error

The status LED lights up or flashes red.
Possible cause
Command format error
(Status LED lights up RED during reception)
Malfunction of a component
(Status LED flashes permanently RED)
Remedy
• Check compatibility
• Check device version
Check version of GRIPLINK controller firmware
• Check device version
• Check version of GRIPLINK controller firmware
• Check communication cable and connections
• Check current consumption of the connected device
Remedy
An error occurred during the evaluation of the incoming command.
• Check version of GRIPLINK controller firmware
• When using an official GRIPLINK plugin: Make sure that the
version of the GRIPLINK plugin works together with the version
of the GRIPLINK firmware.
• When using your own software: Check protocol conversion
At least one component of the controller required for operation
could not be initialized.
• Restart the GRIPLINK controller. If the error persists, send in
the GRIPLINK Controller with a repair order.