Water Filtration System model GX1S01C (Filters not included)
I Check with your local public works department for
plumbing codes. You must follow these guidelines
as you install the Water Filtration system.
I Use the Water Filtration system on a potable, safe-to-drink,
home COLD water supply only. The filter cartridge will not
purify the water, or make it safe to drink.
I Do not use on a hot water supply (100°F. max.).
I Install or store where it will not be exposed to temperatures
below freezing or exposed to any type of weather. Water
freezing in the system will damage it.
I Your Water Filtration system will withstand up to
125 pounds per square inch (psi) water pressure.
If your house water supply pressure is higher than 100 psi,
install a pressure reducing valve before installing the
Water Filtration system.
REQUIRED TOOLS FOR INSTALLATION
I Slotted and Phillips screwdrivers
I Pliers and adjustable jaw wrench
GX1S01C is Tested and Certified
by NSF International against
NSF/ANSI Standards 42 and 53
for the reduction of the claims
specified on the Performance
Data Sheet.
Replacement Filter (not included)
FXUTC – Taste and Odor
FXULC (rev. 2) – Lead and Cyst
Inlet-outlet–3/8" NPT
GE SmartWater

INSTALLATION INSTRUCTIONS

SAFETY PRECAUTIONS

SPECIFICATION GUIDELINES
Service
flow rate
1.0 gpm
0.6 gpm
7239197
215C1044P032
GENERAL ELECTRIC COMPANY, Appliance Park, Louisville, KY 40225
WARNING:
Do not use with water that is
microbiologically unsafe or of unknown quality without
adequate disinfection before or after the system. Systems
certified for cyst reduction may be used on disinfected
water that may contain filterable cysts.
Discard all unused and packaging material after
installation. Small parts remaining after installation
could be a choke hazard.
OPTIONAL KITS AND TOOLS FOR INSTALLATION
NOTE: Installation kit (SSKIT), sump wrench (UCWRNCH)
and faucet (UNFCTBL or UNFCTWW) are sold separately
for model GX1S01C.
I Hand- or battery-powered drill and
valve installation)
I Electric drill and drill bit to drill
required) if mounting hole is needed for faucet
I Pipe cutter
I File
CAUTION:
To avoid damaging the sink, consult a
qualified plumber or installer for drilling procedures.
Special drill bits may be needed for porcelain or
stainless steel.
Capacity
3000 gal. or 6 months
600 gal. or 6 months
49-50191
(01-06 JR)
1
" bit (saddle
1
4
" hole (type as
3
4
Pressure
Temperature
40–125 psi
40–100°F
40–125 psi
40–100°F

Advertisement

Table of Contents
loading

Summary of Contents for GE SmartWater GX1S01C

  • Page 1: Installation Instructions

    FXUTC – Taste and Odor FXULC (rev. 2) – Lead and Cyst Inlet-outlet–3/8″ NPT GENERAL ELECTRIC COMPANY, Appliance Park, Louisville, KY 40225 GE SmartWater SAFETY PRECAUTIONS WARNING: microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
  • Page 2: Installation Options

    CAUTION: For connection to cold water line only. Option 1: For connection to primary sink faucet NOTE: For use with filter element FXUTC ONLY. Use of other filter elements could adversely affect main faucet flow rate. Required Tool Kit (sold separately) I Installation Kit –...
  • Page 3: Flush Procedure

    FLUSH PROCEDURE The procedure for flushing the GE Water Filtration system is: See Filter Cartridge Installation or Replacement section and follow steps 1, 2, 3 and 4. Next, reinstall the sump (without the filter element), turn water on and flush water through the faucet.
  • Page 4: Part Description

    To know what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General. Contact us at ge.com, or call toll-free at 800.952.5039 in the U.S., or 866.777.7627 in Canada. PART DESCRIPTION SCREW #10-14 X 3/4″...
  • Page 5: Instructions D'installation

    FXUTC – Goût et odeur FXULC (rév. 2) – Plombe et cystes Raccords 3/8 po NPT pour entrée et sortie GENERAL ELECTRIC COMPANY, Appliance Park, Louisville, KY 40225 GE SmartWater MESURES DE SÉCURITÉ AVERTISSEMENT : de l’eau microbiologiquement polluée ou de qualité...
  • Page 6: Fixation De La Bride De Montage Sur Un Placard

    MISE EN GARDE : Installer ce produit uniquement sur une canalisation d’eau froide. Option 1 : Raccordement sur canalisation du robinet principal de l’évier NOTE : Pour utilisation UNIQUEMENT avec l’élément de filtration FXUTC. L’emploi d’un autre élément de filtration pourrait réduire le débit du robinet principal.
  • Page 7: Méthode De Purge

    Chaque fois que le système de filtration GE est exposé à de l’eau de qualité inconnue, on devrait jeter les éléments de filtration et rincer le circuit. Circonstances qui peuvent nécessiter un rinçage du circuit : I Notification de la nécessité de faire bouillir l’eau.
  • Page 8: Liste Des Composants

    État ou le procureur général de votre État. Contactez nous sur ge.com, ou appelez le numéro sans frais 800.952.5039 aux États-Unis. Au Canada, contactez nous sur www.electromenagersge.ca, ou appelez le numéro sans frais 866.777.7627.
  • Page 9: Instrucciones De Instalacion

    FXUTC – Taste and Odor FXULC (rev. 2) – Lead and Cyst Entrada-salida–3/8″ NPT GENERAL ELECTRIC COMPANY, Appliance Park, Louisville, KY 40225 GE SmartWater ADVERTENCIA: microbiológicamente segura o de calidad desconocida sin una desinfección adecuada antes o después del sistema.
  • Page 10: Opciones De Instalacion

    PRECAUCION: Para conexión a línea de agua fría solamente. Opción 1: Para conexión a la llave primaria de la llave del lavaplatos. NOTA: Para uso con el elemento de filtro FXUTC SOLAMENTE. El uso de otros elementos podrían afectar adversamente el valor del paso de la llave principal.
  • Page 11: Procedimiento De Lavado

    Cerciórese que esté bien asentada en su ranura. PROCEDIMIENTO DE LAVADO El procedimiento para lavar el sistema de Filtración de Agua GE es: Vea la sección Instalación y Reemplazo del Cartucho del Filtro y siga los pasos 1, 2, 3 y 4.
  • Page 12: Lista De Partes

    GARANTIA DEL SISTEMA DE FILTRACION DE AGUA GE • ¿Qué cubre esta garantía? — Cualquier defecto de fábrica en los materiales o la manufactura del producto. • ¿Qué no cubre esta garantía? — Cartucho del filtro y las baterías después de treinta días a partir de la fecha de la compra.

Table of Contents