Page 1
GAS LAVA ROCK GRILL Installation and Operation Manual Model No: GLK473C GLGK400-E Important: 1. You are advised to read these instructions first before installation commences. 2. This manual must be handed to the end user after installation and commissioning. 3. These instructions are only valid if the country code appears on the appliance. If the code does not appear on the appliance, refer to the technical instructions for adapting the appliance to the conditions for use in that country.
INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS ARE TO BE POSTED IN A PROMINENT LOCATION. THIS INFORMATION SHALL BE OBTAINED BY CONSULTING THE LOCAL GAS SUPPLIER. Technical specification Technical Specifications Table MODEL GLK473C/ GLGK400-E DIMENSIONS WIDTH (mm) DEPTH (mm) HEIGHT (mm) GAS FEED PIPE G1/2〃...
2. Safety 2.1 Using the appliance safely Being an appliance designed only for professional use, it should be operated by qualified personnel exclusively. Never leave the appliance unattended while it is on. Do not move the appliance while hot. 2.2 Safety instructions in case of malfunction If the appliance will remain idle for some time or in the event of a failure, abnormal operation, etc., turn off the shutoff valve upstream of the appliance.
Page 4
4.2 Exhausting fumes The appliance should be installed in a well-ventilated area, if possible under a vent hood, in compliance with all applicable regulations in force. This will ensure that all burnt gases produced during the combustion process are completely exhausted. NOTE: Do not obstruct or block the appliances flue.
Page 5
Table 1: gas categories and pressure values NOTE: ALL GAS FITTING MUST ONLY BE CARRIED OUT BY A QUALIFIED PERSON. This appliances do not require an electrical connection, as they function totally on the gas supply only. It is essential that the gas supply is correct for the appliance to be installed and that adequate supply pressure and volume are available.
Page 6
Table 2: burner specifications Nominal Heat Input (kW) Low Heat Input per Burner (kW) Liquid gas consumption 0.55 (kg/h) Natural gas consumption 0.74 /h) - G20 Rated pressure (mbar) Max pressure(mbar) Min pressure(mbar) Nozzles Pilot flame 0.35 Injector 2.05 Rated pressure (mbar) Max pressure(mbar) Min pressure(mbar) Nozzles...
5. Adjustment Instructions To convert (for example) from natural gas to liquid gas, you need to change the nozzles of main and pilot burners. The appropriate nozzles are shown in "Table 2: burner specifications". Pic 1: Nozzle 5.1 Adjust air ratio device Unscrew the control panel thus can see the adjust air ratio device from bottom view.
Page 8
6.1 Before using the appliance 6.1.1 Preparing the appliance for use Before cooking food for the first time, we recommend cleaning the appliance thoroughly. Remove all packaging materials and adhesive films from the appliance very carefully. Before cleaning the stainless steel parts, make sure that the detergent you intend to use does not contain any abrasive substances and that it is suitable for stainless steel surfaces.
2) Stagnation of ferrous deposits (such as those created by rust dissolved in the water flowing through the piping, especially after the appliance has remained idle for some time). Therefore, avoid such stagnation; do not use wire wool pads to remove the most stubborn food residues. Use, rather, pads or spatulas made of stainless steel or softer, non-ferrous materials;...