I P 6 5 R A T E D
The International Protection (IP) rating system is commonly expressed as "IP" (Ingress Protection) followed by two
numbers (i.e. IP65), where the numbers define the degree of protection. The first digit (Foreign Bodies Protection)
indicates the extent of protection against particles entering the fixture, and the second digit (Water Protection) indicates
the extent of protection against water entering the fixture. An IP65 rated lighting fixture is designed and tested to protect
against the ingress of dust (6), and low-pressure water jets from any direction (5).
Maritime/Coastal Environment Installations: A coastal environment is seaside adjacent, and caustic to electronics
through exposure to atomized salt-water and humidity, whereas maritime is anywhere within 5-miles of a coastal
environment.
Maritime installations require additional preparation, and additional service intervals may be needed given the maritime
use. In general, IP ratings presuppose freshwater conditions VS maritime conditions, which are typically more "caustic"
to IP fixtures (both internally and externally). A duty-cycle may also be needed when units are not in use. During times of
high humidity and colder temperatures, condensation may occur internally so the fixture may require a duty-cycle to
bring it up to running temperature, allowing any accumulation of moisture to be expelled via the vent valve.
Recommendations can change based on installation environmental circumstances.
NOTE: NOT ALL FEATURES LISTED ARE AVAILABLE ON ALL FIXTURES; THE FOLLOWING INSTRUCTIONS MAY
NOT APPLY. CONTACT SUPPORT FOR ADDITIONAL DETAILS.
Exterior Maintenance: Inspect the exterior every 30-days. The unit must be powered off/disconnected. The chassis
should be inspected for any signs of contaminants. Inspect optics to determine if the lens is obstructed, then clean
optics and chassis accordingly. Based on initial finding, schedule maintenance accordingly, keeping in mind that exterior
maintenance will be required. Even if the luminaires are NOT in use, maintenance will still be needed given its location
(exterior use). The use of a durable type of wax on the chassis is recommended since it will help prevent contaminant
build up. Inspect both power and data lines for any signs of contaminants or corrosion. Periodically reapplying di-electric
grease, especially in coastal environments. If any signs of corrosion/contaminants are present, clean thoroughly, and/or
replace connectors, then reapply di-electric grease. Typically, this should be done annually, or any time an opportunity
presents itself. As a preventive measure, annual replacement of both vent valves is recommended. The vent valve
membrane can become contaminated and/or clogged causing improper venting of humidity within the luminaire. Inspect
all mounting hardware as a precaution.
Interior Maintenance: Inspect the interior every 30-days. The unit must be powered off/disconnected.
Inspect zoom/focus mechanism, clean optics, lubricate linear bearings (Krytox oil) as needed, inspect belts for wear
Inspect all rotating effect wheels, manually rotate them, note any resistance
Inspect all remaining rotating belts for any wear
Inspect all fans, clean as needed, check rotation, check connections
Inspect CMY module, manually move flags and check for signs of resistance, and if needed, clean guide rods first,
then reapply a thin layer of grease (moly lube)
Clean interior with low-volume compressed air, then clean optics prior to reassembly of head covers
Although the base has limited moving parts, the pan belt should also be inspected for wear. Remember to always
perform an IP test anytime a cover is removed.
There is no specific time frame regarding the routine replacement of parts such as belts/stepper motors, PCBs, or LEDs.
These items should only be replaced on an as needed bases, except for cooling fans, which should be replaced once the
luminaries reach 10,000-hours. This is a prophylactic measure intended to keep the unit running as cool as possible,
insuring proper function of all internal components. A complete service breakdown is available, please contact