5.4.5.
To display correction factor and Total (fig.8)
Hold MOVE and RESET for 3 seconds
Value "1.4000" is correction factor.
"1234567" overall total
5.4.6.
To change Units (fig.9)
Hold MOVE and RESET for several seconds
Area 2 in fig.5 shows units
Press RESET to change units
Press and hold MOVE to confirm choice
5.5.
DETERMINING THE CORRECTION FACTOR
5.5.1.
Dispense at least 1 litre of liquid into a calibrated container.
5.5.2.
Record the quantity of liquid in the container and record the quantity of
liquid dispensed as indicated on the meter display. Press the
Move + Reset buttons (fig.5.5 and fig.5.5) simultaneously to display
the current correction factor.
Qty Dispensed
x Current Correction Factor = New Correction Factor.
Qty Indicated
5.6.
ALTERING CORRECTION FACTOR DIRECTLY
5.6.1.
Wait for meter to go to standby (fig.7).
5.6.2.
Reset total (5.2.4) fig.8 to zero.
5.6.3.
Press and hold MOVE key until all digits illuminate and display shows 'Cal' (fig.9).
5.6.4.
Press RESET to set digit values (from right to left) (fig.10).
5.6.5.
Once value is correct hold down MOVE key until Cal mode quits.
5.7.
ALTERING CORRECTION FACTOR INDIRECTLY
5.7.1.
Wait for meter to go to standby (fig.10).
5.7.2.
Reset the total (5.4.4) fig.11 to zero.
5.7.3.
Dispense into measuring container (minimum 5 litres) and record.
5.7.4.
If displayed value does not match actual measured value
press and hold MOVE key until each digit reads as per the
measured value. Press MOVE key to visit each digit in turn.
5.7.5.
Once value is correct (i.e. matches measured value) press and
hold MOVE key until Cal mode quits (fig.11).
6. MAINTENANCE
6.1.
CHANGING THE DIGITAL METER BATTERY
6.1.1.
Remove the rubber protective cover from the meter.
6.1.2.
Remove the screw and cover from the side of the meter.
6.1.3.
Remove and replace battery (fig.14).
6.1.4.
Replace cover and secure with screw.
6.1.5.
Replace the protective rubber cover.
NOTE: If the LCD display does not activate, remove the meter, press button 1 (fig.5.5) to reboot the meter.
6.2.
Before every use visually check the supply hose for damage and check all joints for leaks, any damaged component must be
replaced or leaks repaired before using.
6.3.
Check the nozzle valve for leaks, if it does not seal, replace before using.
6.4.
Drain air regulator water trap daily.
6.5.
Top up lubricator as required, using a quality air tool oil.
6.6.
To change the silencer, remove the circlip (fig.15) and remove the old silencer, place a new silencer into the recess and refit the
circlip.
NOTE: For any other maintenance and repairs the unit should be returned to your Sealey stockist.
fig.14
© Jack Sealey Limited
fig.8
fig.12
fig.15
Original Language Version
fig.9
fig.10
fig.11
fig.13
AK4560D.V2 Issue 1 25/05/21