Operational Specification - Acer G225HQ Service Manual

Table of Contents

Advertisement

3.2. Operational Specification

3.2.1 Power supply
Item
Input Voltage range
Input Current range
Power Consumption
DPMS
DPMS
Inrush Current
Earth Leakage Current
Hi-Pot
Power Line Transient
CCFL operation range
CCFL Frequency
Power cord
Condition
Universal input full range 90~264VAC /47~63Hz
90 ~ 264VAC
Normal "On" operation
DPMS "Sleep" state
DPMS "Off" state
110 VAC
220 VAC
264 VAC/50Hz
1. 1500VAC, 1 sec
2. Ground test: 30A,
1sec
IEC1000-4-4
IEC1000-4-5 (Surge)
90 ~ 264VAC
90 ~ 264VAC
- 7 -
Spec
< 2.0 Arms
< 52 W
< 2 W
< 1 W
< 30 A (peak)
< 60 A (peak)
< 3.5 mA
Without damage
< 0.1 ohm
1KV
Common: 2KV,
Differential: 1KV
LGD: 3~8mA
SEC : 4~8mA
40KHz ~ 60KHz
Color: Black
Length: 1800 +/- 50 mm
OK N.A Remark
LED: Blue
LED: Amber
LED: OFF
Cold-start
(on-line test)
(in-lab test)
Depends on panel
source
Depends on panel
source