Recommended ba�ery se�ngs
Battery Type
AGM (or PCC)
Gel
Wet
Lithium

5.7 System Work Mode Setup Menu

System Work Mode
12000
Selling First
Zero Export To Load
Zero Export To CT
Max Sell Power
12000
Zero-export Power
Energy pattern
BattFirst
Grid Peak Shaving
8000
Zero Export To Load: Hybrid inverter will only provide power to the backup load connected. The hybrid
inverter will neither provide power to the home load nor sell power to grid. The built-in CT will detect
power flowing back to the grid and will reduce the power of the inverter only to supply the local load and
charge the ba�ery.
Solar
Zero Export To CT: Hybrid inverter will not only provide power to the backup load connected but also give
power to the home load connected. If PV power and ba�ery power is insufficient, it will take grid energy
as supplement. The hybrid inverter will not sell power to grid. In this mode, a CT is needed. The installa�on
method of the CT please refer to chapter 3.6 CT Connec�on. The external CT will detect power flowing back
to the grid and will reduce the power of the inverter only to supply the local load, charge ba�ery and home
load.
Solar
Absorption Stage
14.2v (57.6v)
14.1v (56.4v)
14.7v (59.0v)
Follow its BMS voltage parameters
Max Solar Power
Work
Solar Sell
Mode1
Solar Sell
20
LoadFirst
Power
Battery
Battery
Float Stage
13.4v (53.6v)
13.5v (54.0v)
13.7v (55.0v)
Work Mode
Selling First: This Mode allows hybrid inverter to sell
back any excess power produced by the solar panels to
the grid. If �me of use is ac�ve, the ba�ery energy also
can be sold into grid.
The PV energy will be used to power the load and charge
the ba�ery and then excess energy will flow to grid.
Power source priority for the load is as follows:
1. Solar Panels.
2. Grid.
3. Ba�eries (un�l programable % discharge is reached).
Backup Load
On-Grid Home Load
Backup Load
On-Grid Home Load
- 33 -
Torque value
(every 30 days 3hr )
14.2v(57.6v)
14.7v(59.0v)
Grid
Grid
CT