NBE100 User's Manual
®
Figure 2 – NMEA 2000
Connector Face Views
®
The NBE100 is installed on an NMEA 2000
network between the two sections that you wish
to physically isolate. There is no electrical connection through the NBE100, so you must
®
ensure that each of the two NMEA 2000
networks connected to the NBE100 must have
separate power sources and two termination resistors. This means that if you use an NBE100
to split an existing network into two separate networks, you must provide one additional power
connection and two additional termination resistors (one for each side of the NBE100).
®
The two NMEA 2000
connectors are labeled "N2K PORT A(PWR)" and "N2K PORT B".
Logically, these connectors are identical; that is, you can connect the NBE100 between two
networks in either way and it will function identically. However, the NBE100 sources power
only from the connector marked "N2K PORT A(PWR)". It uses no power from the connector
labeled "N2K PORT B".
®
Figure 3 below shows the installation of an NBE100 into a simple NMEA 2000
network.
For exceptionally large networks, multiple NBE100's may be used to segment the network into
more than two segments. Each segment must have its power connection and two termination
resistors.
.
Page 4
Revision 1.0