1. Remove fi xture components and parts pack. Check to ensure
all parts are included. Note: Account for small parts and destroy
packing material, as these may be hazardous to children.
Turn OFF Power at circuit breaker box!
CAUTION: Do not rely on wall switch alone to turn off power.
Note: NOT suitable for use with dimmers, motion sensors or other
remote devices.
2. Photocontol Installation
Install Photocontrol by aligning the
arrow on top of the Photocontrol with
the arrow on the receptacle. Push
down and twist clockwise until it clicks.
Note: For optimal performance the arrow on the photocontrol
should be facing north after fi xture is installed. If adjustment is
needed, loosen the Screw in the center of the white photocontrol
receptacle two turns. Rotate receptacle so that the arrow will
point north when installed and re-tighten Screw. Note: There is
a stop to prevent the receptacle from turning all the way around.
If you have trouble turning the receptacle, try turning it the other
direction.
Note: Keep photocontrol or Shorting Cap installed to ensure that
no water will enter photocontrol receptacle.
Fixture Mounting
Note: Hardware included for mounting to wood surfaces only!
Ensure that fi xture is mounted onto structurally sound surface that
will support the fi xture.
Optional Mounting Arm available (sold separately).
3. Mark hole locations using the template on the box and drill
3/16" diameter pilot holes.
4. Install two 2" Screws (4) in bottom holes, leaving about 3/8"
space under the head.
5. Install the third 2" Screw (4) into the predrilled hole on top and
back the Screw out. This will leave the hole threaded and make
installation easier.
6. Place Fixture Housing on the two bottom Screws and install
third Screw.
7. Tighten two bottom Screws to secure fi xture.
CAUTION: WIRING AND FIXTURE OPERATION
Make sure power is turned off!
8. Remove knockout on bottom of Cover Plate (5) and feed house
supply wires through hole. Note: This fi xture is intended for use
with conduit connectors, conduit and junction box that are UL
listed suitable for wet locations and are properly installed and
grounded. See Fig. A.
9. Ground fi xture
Use Wire Nut (6) to connect the (copper) house supply ground
wire & the (green) fi xture ground wire.
Note: If house wiring does not include a ground wire, consult your
local electrical code for approved grounding methods.
For proper connection, place wire nut over wires
and twist clockwise until tight.
Photocell
Installation:
Align
"FACE NORTH"
arrow on top of
photocell with
white arrow on
re ce ptacle
before
pho to con trol
installation.
10. Connect supply wires
Use Wire Nuts (6) to connect the black fi xture wire to the black
power supply wire and the white fi xture wire to the white (neutral)
supply wire.
11. Secure Cover Plate (5) to housing with two 1" Bolts (3).
12. If desired, install decorative Diffuser. Align the keyholes
along the diffuser rim with the 3 screw heads around the edge of
the fi xture bottom, push up and rotate counter clockwise to install
and tighten screws to secure.See Fig. B.
13. Turn on electricity at fuse or circuit breaker box and verify
success of installation. Note: Test fi xture at night or block
Photocontrol.
14. Apply silicone caulking (not included) for moisture seal.
page 3

INSTALLATION INSTRUCTIONS

Figure A
3) 1" Bolt
2) Photocontrol
1) Housing Assembly
4) 2" Screws
5) Cover Plate
Figure B