Page 1
USER GUIDE & SERVICE MANUAL Model: UHRF124-IS01A...
Page 2
USER GUIDE & SERVICE MANUAL Click on any section below to jump directly there Table of Contents Service Intro Troubleshooting Safety Wire Diagram Safety and Warning Product Liability Disposal And Recycling Warranty Claims Parts Installation Ordering Replacement Parts Environmental Requirements R600a Specifications Electrical System Diagnosis Guide...
Page 3
U-Line Customer Care must be contacted immediately at +1.414.354.0300. Service or repairs performed on the unit without prior written approval from U-Line is not permitted. If the unit has been altered or repaired in the field without prior written approval from U-Line, claims will not be eligible.
Page 4
USER GUIDE Safety and Warning DANGER NOTICE This unit contains R600a (Isobutane) which is a Please read all instructions before installing, flammable hydrocarbon. It is safe for regular operating, or servicing the appliance. use. Do not use sharp objects to expedite defrosting.
Page 5
USER GUIDE Disposal and Recycling DANGER RISK OF CHILD ENTRAPMENT. Before you throw away your old refrigerator or freezer, take off the doors and leave shelves in place so children may not easily climb inside. If the unit is being removed from service for disposal, check and obey all federal, state, and local regulations regarding the disposal and recycling of refrigeration appliances, and follow these steps completely:...
Page 6
USER GUIDE Environmental Requirements This model is intended for indoor/interior applications only and is not to be used in installations that are open/ exposed to natural elements. This unit is designed to operate between 50°F (10°C) and 100°F (38°C). Higher ambient temperatures may reduce the unit’s ability to reach low temperatures and/or reduce ice production on applicable models.
Page 7
USER GUIDE Electrical WARNING SHOCK HAZARD — Electrical Grounding Required. Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected. Never remove the round grounding prong from the plug and never use a two-prong grounding adapter.
Page 8
23 ⁄ ” Cutout & Product Dimensions (608 mm) PREPARE SITE Your U-Line product has been designed for either free- standing or built-in installation. When built-in, your unit FRONT does not require additional air space for top, sides, or 34 ⁄ ” to 35 ⁄ ”...
Page 9
USER GUIDE Side-by-Side Installation 3. Place bracket over holes and attach to unit with two screws removed in step 2 using a T-25 Torx driver. Two units may be installed side-by-side. Tighten screws fully. Cutout width for a side-by-side installation is the cutout 4.
Page 10
USER GUIDE Anti-Tip Bracket Slide unit out so screws on top of unit are easily accessible. Remove the two screws from the opposite side of the hinge assembly using a T-25 Torx driver (see below). Place bracket over holes and attach to unit with two screws removed in step 2 using a T-25 Torx driver.
Page 11
USER GUIDE General Installation INSTALLATION Plug in the power/electrical cord. LEVELING INFORMATION Gently push the unit into position. Be careful not Use a level to to entangle the cord or water and drain lines, if confirm the unit is applicable. level.
Page 12
USER GUIDE USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Integrated Panel Dimensions 2. Optional: Stain or Finish panel to desired stain or color. Be sure to closely follow the instructions provided by INTEGRATED PANEL the manufacturer.
Page 13
Clamp using clamps. A robust tape may also 5. Partially loosen the 3 screws, securing the top hinge to be used. U-Line the cabinet. recommends the use of bar clamps to Door/Drawer 6. Align the panel with the outside edge (opposite the...
Page 14
USER GUIDE USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE 12.Using a Phillips screwdriver, place one screw into each of the 6 pilot holes and screw down. Do not overtighten screws. 13.Be sure the screws force their way past the opening on the gasket channel and sit flush against the bottom of the channel.
Page 15
Align cabinet and grille holes and secure, but do not over tighten grille screws (1). Note: When installing next to a 15” wide U-Line product, use the supplied spacers behind the grille. The 24” grille will now be on the same plane as the 15”...
Page 16
USER GUIDE Door Swing Wall 2-1/8" Min. (54 mm) 90° Door Swing Units have a zero clearance for the door to open 90°, when installed adjacent to cabinets. Stainless Steel models require 2-1/8" (54 mm) door clearance to accommodate the handle if installed next to a wall.
Page 17
USER GUIDE USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Door Adjustments TO REVERSE THE DOOR DOOR ALIGNMENT AND ADJUSTMENT Align and adjust the door if it is not level or is not sealing properly.
Page 18
On some models there may be a nut behind one or both screws on either side. Open end of bracket u-line.com Remove corresponding screws on opposite side of Install bottom hinge: Note: It is necessary to remove and switch the cabinet.
Page 19
Free Standing Kit Te free standing kit is an optional accessory (ULAFREESTANDS), used when unit is freestanding - not built into a cabinet. Available at u-line.com. To install the kit: Remove grille (see GRILLE INSTALLATION section). Align front hole wit hole in shell accessory, hole in base, and hole in grille.
Page 20
If the temperature displayed is different than selected, the unit is progressing towards the selected temperature. Time to reach set point varies based upon ambient temperature, temperature of product loaded, door openings, etc. U-Line recommends allowing the unit to reach set points before loading.
Page 21
USER GUIDE Control Operation CONTROL FUNCTION GUIDE FUNCTION COMMAND NOTES ON/OFF Press and release Unit will immediately turn On or OFF Press and release to leave interior After 12 hours, factory default is restored; light will Leave interior light on light on for 12 hours;...
Page 22
⁄ ” ⁄ ” (66 mm) (64mm) When determining capacities U-Line uses typical 12 oz. cans, 12 oz. bottles, 750 mL white wine and red wine bottles shown below. ⁄ ” ⁄ ”...
Page 23
USER GUIDE Interior Adjustments INTERIOR SHELVES Removing and Installing Interior Shelves For models equipped with glass shelves having recessed shelf supports, remove the shelves as follows: Pull shelf out about 6” (1), until back of shelf clears the “hump” on the right-hand side. Tilt up right-hand edge of shelf (2).
Page 24
USER GUIDE Cleaning To clean integrated panels, use household cleaner per the cabinet manufacturer’s recommendation. Stainless Models Stainless door panels and handles can discolor when INTERIOR CLEANING exposed to chlorine gas, pool chemicals, saltwater or Disconnect power to the unit. cleaners with bleach.
Page 25
USER GUIDE NOTICE The drain pan was not designed to capture the water created when manually defrosting. To prevent water from overflowing the drain pan and possibly damaging water sensitive flooring, the unit must be removed from cabinetry. To defrost: 1.
Page 26
USER GUIDE USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Cleaning Condenser INTERVAL - EVERY SIX MONTHS To maintain operational efficiency, keep the front grille free of dust and lint, and clean the condenser when necessary.
Page 27
If the unit will be exposed to temperatures of 40°F (5°C) or less, the steps above must be followed. For questions regarding winterization, please call U-Line at 414.354.0300. CAUTION Damage caused by freezing temperatures is not covered by the warranty.
Page 28
USER GUIDE Troubleshooting • Automatic Defrost Drain Pan: Water may be heard dripping or running into the drain pan when the unit is BEFORE CALLING FOR SERVICE in the defrost cycle. If you think your product is malfunctioning, read the TROUBLESHOOTING GUIDE CONTROL OPERATION section to clearly understand the function of the control.
Page 29
USER GUIDE Problem Possible Cause and Remedy Product is Not Cold Air temperature does not indicate product Enough temperature. See CHECKING PRODUCT TEMPERATURE below. • Adjust the temperature to a cooler set point. • Ensure unit is not located in excessive ambient temperatures or in direct sunlight.
Page 30
USER GUIDE u-line.com Wire Diagram Wire Diagram...
Page 31
The part that caused the damage must be returned to U-Line in its entirety. The part must be clearly labeled with the serial number of the unit it was removed from, the date, and the servicer who removed the part.
Page 32
Claims must be submitted online at • Final billing - Remodel www.U‑LineService.com Warranty parts will be shipped at no charge after U-Line • 60 day submittal deadline from date of completed confirms warranty status. Please provide the model, serial service number, part number and part description.
Page 33
USER GUIDE Parts 18 19 UHRF124-IS01A Item Description U-Line P/N ANTI TIP BRACKET W/SCREWS 80-54239-00 BACK PANEL 80-54853-00 COMPRESSOR EM2C46CLC,115V,R600 80-55658-11 CONDENSER ASSEMBLY 80-54301-01 CONDENSER FAN W/SCREWS 80-54014-00 DISPLAY ASSEMBLY, WHITE 80-55400-01 DOOR ASSEMBLY, INT W/HINGES 80-54316-00 DRAIN PAN 80-54217-00...
Page 34
Warranty parts will be shipped at no charge after U-Line confirms warranty status. Please provide the model, serial number, part number and part description. Some parts will require color or voltage information.
Page 35
Never use a torch on a fully charged refrigeration system. Never substitute U-Line OEM replacement parts or methods of construction. R-600a must be stored and transported in Technician must observe all federal, state and local laws regarding refrigerants.
Page 36
USER GUIDE USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE R-600A SPECIFICATIONS/LABELING WARNING R-600a equipped products are labeled (both the unit and the compressor). Only skilled and well trained service technicians permitted to service R-600a equipped products.
Page 37
USER GUIDE USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Evacuate/reclaim via the piecing pliers to ensure the When re-brazing, the system must be purged with dry system is empty of R-600a before any system work is nitrogen and at least one access point open to the performed.
Page 38
USER GUIDE USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE The low side of the refrigeration system (evaporator, Proper ventilation during service is required. compressor and suction line) must be leak tested with the compressor off (equalized pressure).
Page 39
USER GUIDE System Diagnosis Guide REGRIGERATION SYSTEM DIAGNOSIS GUIDE System Suction Suction Compressor Condenser Capillary Evaporator Wattage Condition Pressure Line Discharge Tube Normal Normal Slightly Very hot Very hot Warm Cold Normal below room temperature Overcharge Higher than Very cold Slightly warm Hot to warm Cool...
Page 40
USER GUIDE Compressor Specifications DANGER EM2C46CLC-115V REFRIGERANT R600a VOLTAGE 115V – 127V Electrocution can cause death or serious injury. FREQUENCY 50Hz Burns from hot or cold surfaces can cause serious START WINDING 5.20 +/- 8% Q at 25 °C (77°F) injury.
Page 41
USER GUIDE USER GUIDE Adjust refrigerator Light Button Push and release u-line.com u-line.com temperature -Activates light for 3 hours on select models -Used to select items in service menu SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE SAFETY •...
Page 42
USER GUIDE To view the thermistor temperature, push and release the USER GUIDE DISPLAY/OPTIONS up and down keys. The display will show the corrected Unit will immediately turn ON or OFF refrigerator temperature. SAFETY • INSTALLATION & INTEGRATION • OPERATING ve interior light Glass door wine captains and beverage centers only.
Page 43
USER GUIDE USER GUIDE u-line.com ERATING INSTRUCTIONS • MAINTENANCE • SERVICE SAFETY • INSTALLATION & INTEGRATION • OPERATIN SERVICE MODE GUIDE 14. VIEW ERROR LOG A list of the errors in the order they occurred will 1. THERMISTOR 1 — ZONE scroll once on the display.
Page 44
USER GUIDE u-line.com OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE 20. MODEL NUMBER INDICATOR Displays the two-digit model number of the specific unit. See model list table. 21. LIGHT ALL LED SEGMENTS This will illuminate all the LEDs on the display to ensure they work properly.
Page 45
MODEL NUMBER 1. Disconnect the unit from power source. 2. Push and hold the U-Line button. 3. While still holding the U-Line button, plug the unit into the appropriate power source. 4. When the flashing digits appear (3-5 seconds), use the up and down arrow buttons to select the appropriate model number*.
Page 47
For products installed and used for normal residential use, material cosmetic defects are included in this warranty, with coverage limited to 60 days from the date of original purchase. All service provided by U-Line under the above warranty must be performed by a U-Line factory authorized servicer, unless otherwise specified by U-Line.
Need help?
Do you have a question about the UHRF124-IS01A and is the answer not in the manual?
Questions and answers