Ozone is an extremely aggressive gas which - if not used properly - can damage one's
health. For this reason, ozone should never be breathed in directly.
In addition, at high doses ozone can damage the skimmer.
The dosing of ozone must be set so that no free ozone can be discerned on the skimmer lid.
Deltec skimmers can be operated with between 20 and 50 mg/hours of ozone per pump. An
ozone-resistant T-piece is placed in the air hose above the skimmer pump. The free end of
the T-piece is connected to the ozonizer by means of an ozone-resistant hose. The air valve
of the skimmer must be throttled until air is independently sucked through the ozonizer.
Safety information:
The maximum ozone quantity of 50mg/hour per pump must not be exceeded.
-
The air passage can be reduced as a result of dust deposits in the ozonizer. This can
-
result in an increase in the water level in the skimmer, which - in extreme cases - can
overflow. To avoid this, check the ozonizer regularly to make sure that there are no
deposits of dust. If necessary, clean it.
Never breathe in free ozone.
-
The ozonizer may not be directly connected to the air valve or silencer.
-
In order to avoid water damage, the ozonizer must be placed high enough to ensure
-
that no water can penetrate it when the skimmer pump is switched off.
If the skimmer is used with new water it is common to find an excessive quantity of small
bubbles and often the skimmer cup fills with a clear liquid. This is due to the high surface
tension of the new water which prevents the bubbles from bursting. Once the water
matures this effect will go away but it can take up to 2-3 weeks. The effect is different on
different salt brands and is often dependant on levels of conditioning agents added to the
salt. Once these are skimmed out then the skimmer will act normally.
Heavier feeding in the initial stages will give the chemically pure water something to react
with and allow it to mature into proper aquarium salt water rather than the initial chemical
soup which is new salt water.
Dimensions
technical
data
TC Serie
Footprint height
TC 2000ix
280x400
TC 3000ix
320x430
TC 6000ix
380x450
TC 9000ix
570x590
TC 12000ix
640x690
Operation with ozone
Fresh salt water

Technical Data

Aquarium size
mm
litre
Height
under
high
outlet
stocking
pipe
600
281
1000
600
270
2000
680
265
3000
780
280
6000
780
280
9000
Water flow
rate
litre/h
normal
recommended
stocking
2000
2500
3000
3600
6000
3600
9000
9000
12000
12000
-16-
Power
Air
consumption
Watt
Litre / h
22
1300
34
1800
68
3600
111
5700
148
7600
Connections Ø
mm
Feedline
Outlet
32
50
32
50
32
50
40
63
40
63