Wiring Diagram Notes - Carrier TCSNAC01-A Installation Instructions Manual

Table of Contents

Advertisement

Thermostat
O/B
Heat
W
Cool
Y
Fan
G
24VAC
R
*
Common
C
*Common connection not required if batteries are used.
Fig. 3 - - HP Thermostat with Fan Coil
1. Furnace must control its own second- -stage heat operation via furnace control algorithm. Refer to indoor equipment Installation
Intructions for proper setup.
2. See Option 5 information to convert HP thermostats to AC thermostat operation.
3. As an option, lock the furnace into low- -heat operation and let O/B control high- -heat operation. Refer to indoor equipment Installation
Instructions for proper setup.
4. O/B can control second- -stage heat. Refer to indoor equipment Installation Instructions for proper setup.
5. Refer to outdoor equipment Installation Instructions for latent kit requirements (if any).
6. Terminals marked with * may not be present on equipment.
7. O/B energizes reversing valve in cooling or heating. See Option 10.
8. Refer to outdoor equipment Installation Instructions for proper setup.
9. If system is wired per diagram, the ACRDJ (jumper) on furnace control board should be removed to allow thermostat to control
outdoor unit staging.
10. Refer to fan coil Installation Instructions for proper wiring.
11. If batteries are installed, C (common wire) is not required between indoor unit and thermostat.
Fan Coil
Heat Pump
O
W
W
Y
Y
G
R
R
C
C
A08163

WIRING DIAGRAM NOTES:

Thermostat
Heat
W
Cool
Y
Fan
G
24VAC
R
*
Common
C
*Common connection not required if batteries are used.
Fig. 4 - - AC Thermostat with Fan Coil
6
Fan Coil
Air Conditioner
W
W
Y
Y
G
R
R
C
C
A08164

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tcsnhp01-a