Circulating fluid temperature controller (32 pages)
Summary of Contents for SCM HRLE090
Page 1
60 Hz 50/60 Hz Power consumption 3-phase 200 VAC Energy saving reduced by 17% 3-phase 200 to 230 VAC 3-phase 380 to 415 VAC 3-phase 460 to 480 VAC Single-phase 200 to 230 VAC HRLE : HRLE090 HRLE050 Series CAT.ES40-75A...
Page 2
2 channels Compact Less work-hour for wiring Height Power cable entry [mm] Series Height Width Depth Depth HRLE090 1055 HRSH090 1080 Width Compressor Compressor Energy saving reduced by 17% Power consumption Pump Pump ¡1 compressor, fan, and pump ¡Uses a heating method that does not require a heater...
Page 3
8.5 kW load 0 kW load When a load is stable ∗ For HRLE090-A-20 ±0.5 ° C ¡Outdoor air temperature: 32°C ¡ Circulating fluid set temperature: 20°C/25°C (CH1/CH2) ¡ H eat load in the customer equipment: 9.5 kW (CH1, 2 total) Heat load fluctuation ¡Power supply: 200 V 60 Hz...
Page 4
Time [Minute] temperature is low. ∗ For HRLE090-A-20 ¡Ambient temperature: 32°C ¡Power supply: 200 V 50 Hz Customer ¡ C irculating fluid flow rate: [CH1] 35 L/min at 0.5 MPa, [CH2] 2 L/min at 0.5 MPa equipment ¡Circulating fluid temperature: [CH1] 15°C R 25°C, [CH2] CH1 + 5°C...
Page 5
Rotation Rotation Locking lever Increased cooling capacity function (Option) ∗ HRLE090 only 60 Hz 50 Hz The inverter for compressor increases the cooling capacity of the 50 Hz area to that of the 60 Hz area. Ambient temperature 40°C Ambient temperature 40°C Ambient temperature 45°C...
Page 6
Circulating Fluid Temperature Controller Thermo-chiller HRLE Compact Dual/Basic Type for Lasers Air-cooled Refrigeration Water-cooled Refrigeration Series Convenient functions (Refer to the Operation Manual for details.) Anti-freezing operation function Key-lock function If the circulating fluid approaches its freezing point, for example, on a cold Can be set in advance to protect the set values from being winter night, the pump operates automatically, and the heat generated by changed by pressing keys by mistake...
Page 7
Circulating Fluid Temperature Controller Thermo-chiller HRLE Compact Dual/Basic Type for Lasers Air-cooled Refrigeration Water-cooled Refrigeration Series Global Supply Network SMC has a comprehensive network in the global market. We now have a presence of more than 560 branch offices and distributors in 83 countries and regions worldwide, such as Asia, Oceania, North/ Central/South America, and Europe.
Page 8
Circulating Fluid Temperature Controller Thermo-chiller HRLE Compact Dual/Basic Type for Lasers Air-cooled Refrigeration Water-cooled Refrigeration Series Circulating Fluid Line Equipment Flow Switch: Refer to the Web Catalog for details. Monitors the flow rate and temperature of the circulating fluid 3-Color Display 3-Color Display Digital Flow Switch for PF3W...
C O N T E N T S HRLE Series Compact Dual/Basic Type for Lasers Air-cooled refrigeration Water-cooled refrigeration HRLE Thermo-chiller Series How to Order/Specifications ............p. 9 Air-cooled refrigeration ............p. 11 Water-cooled refrigeration Cooling Capacity ................p. 13 Pump Capacity ................
Thermo-chiller Compact Dual/Basic Type for Lasers HRLE Series Power Single-phase 200 to 230 VAC supply (50/60 Hz) How to Order HRLE A 20 Air-cooled refrigeration Cooling capacity CH1, 2 total 5 kW Air-cooled refrigeration Option Cooling method None Air-cooled refrigeration Deionized water (Pure water) piping Power supply ¡ O ptions “C”...
Page 11
3-phase 200 VAC (50 Hz) With inverter for pump 3-phase 200 to 230 VAC (60 Hz) ¡ W hen multiple options are combined, indicate the symbols in alphabetical order. Specifications HRLE090-A-20 Model Cooling method Air-cooled refrigeration Refrigerant R410A (HFC) Refrigerant charge...
Thermo-chiller Compact Dual/Basic Type for Lasers HRLE Series Power Single-phase 200 to 230 VAC supply (50/60 Hz) How to Order HRLE W 20 Water-cooled refrigeration Cooling capacity CH1, 2 total 5 kW Option Water-cooled refrigeration Cooling method None Water-cooled refrigeration Deionized water (Pure water) piping Power supply ¡ O ptions “C”...
3-phase 200 VAC (50 Hz) With inverter for pump 3-phase 200 to 230 VAC (60 Hz) ¡ W hen multiple options are combined, indicate the symbols in alphabetical order. Specifications HRLE090-W-20 Model Cooling method Water-cooled refrigeration Refrigerant R410A (HFC) Refrigerant charge...
Page 14
3-phase 380 to 415 VAC (50/60 Hz) With inverter for pump 3-phase 460 to 480 VAC (60 Hz) ¡ W hen multiple options are combined, indicate the symbols in alphabetical order. Specifications HRLE090-A-40 Model Cooling method Air-cooled refrigeration Refrigerant R410A (HFC)
Page 15
3-phase 380 to 415 VAC (50/60 Hz) With inverter for pump 3-phase 460 to 480 VAC (60 Hz) ¡ W hen multiple options are combined, indicate Specifications the symbols in alphabetical order. HRLE090-W-40 Model Cooling method Water-cooled refrigeration Refrigerant R410A (HFC)
Page 16
Facility water temperature 40°C Facility water temperature 40°C Circulating fluid temperature [°C] Circulating fluid temperature [°C] * The cooling capacity is the sum of the capacities of CH1 and CH2. HRLE090-A-20/40 HRLE090-A-20/40 [50 Hz] [60 Hz] Ambient temperature 32°C Ambient temperature 32°C Ambient temperature 40°C...
Page 17
HRLE Series Thermo-chiller Compact Dual/Basic Type for Lasers Heating Capacity HRLE050-A-20 HRLE050-A-20 [50 Hz] [60 Hz] Ambient temperature 40°C Ambient temperature 45°C Ambient temperature 45°C Ambient temperature 40°C Ambient temperature 32°C Ambient temperature 32°C Ambient temperature 25°C Ambient temperature 25°C Ambient temperature 2°C Ambient temperature 2°C Circulating fluid temperature [°C]...
Casing Circulating fluid flow rate [L/min] Shaft * The pump capacity is the capacity of CH1 when 2 L/min are applied to CH2. Mechanical seal pump Impeller HRLE090-m-20/40 Usable 60 Hz range 50 Hz Usable range 60 Hz 50 Hz...
HRLE Series Thermo-chiller Compact Dual/Basic Type for Lasers Dimensions HRLE050-A-20 Anchor bolt mounting position Ventilation air outlet Ventilation air inlet Ventilation air outlet Parts Description Circulating fluid fill port lid Power supply switch Circulating fluid return Operation display panel Dustproof filter Circulating fluid outlet (CH2) port (CH1) Rc1/2...
Page 20
HRLE Series Compact Dual/Basic Type for Lasers Dimensions HRLE050-W-20 Anchor bolt mounting position Parts Description Circulating fluid fill port lid Power supply switch Circulating fluid return Operation display panel port (CH1) Circulating fluid outlet (CH2) Rc1/2 Rc1/2 Fluid level indicator Circulating fluid return port (CH2) Rc1/2...
Page 21
HRLE Series Thermo-chiller Compact Dual/Basic Type for Lasers Dimensions HRLE090-A-20/40 Anchor bolt mounting position Ventilation air outlet Ventilation air inlet Ventilation air outlet Parts Description Circulating fluid fill port lid Power supply switch Circulating fluid return port Operation display panel...
Page 22
HRLE Series Compact Dual/Basic Type for Lasers Dimensions HRLE090-W-20/40 Anchor bolt mounting position Parts Description Circulating fluid fill port lid Power supply switch Circulating fluid return Operation display panel port (CH1) Circulating fluid outlet (CH2) Rc1/2 Fluid level indicator Circulating fluid return...
HRLE Series Compact Dual/Basic Type for Lasers Operation Display Panel The basic operation of this unit is controlled through the operation panel on the front of the product. w e r t y !6 !8 !7 Item Function PV (Upper line) Displays the circulating fluid current discharge temperature and pressure and alarm codes and other menu items (codes) Digital display (7 segments, 4 digits)
HRLE Series Thermo-chiller Compact Dual/Basic Type for Lasers Communication Functions Contact Input/Output Item Specifications Connector type M4 terminal block Insulation method Photo coupler Rated input voltage 24 VDC Input signal Operating voltage range 21.6 to 26.4 VDC Rated input current 5 mA TYP Input impedance 4.7 kW...
Options Option symbol With Inverter for Compressor HRLE090 With inverter for compressor The inverter for compressor increases the cooling capacity of the 50 Hz area to that of the 60 Hz area. (Refer to the 60 Hz graph under “Cooling Capacity”...
Page 30
!8 Binding band — !9 Reusable band — (170) @0 Sealant tape PTFE @1 DI control solenoid valve extension cable — ∗1 The product should be replaced when it can no longer preserve the electrical conductivity set value. Mounting dimensions: HRLE090...
Page 31
PTFE — ∗ If a handle is required, please order it separately. Handle: HRS-S0600 M Particle filter set (For HRLE050, CH1/CH2) (For HRLE090, CH2) This set can be used to remove foreign matter from the circulating fluid. HRL-PF002 (173) Fluid...
Page 32
Different HRLE090 Rc1 x Rc3/8 Stainless steel For CH1 diameter tee HRLE050 Rc1/2 x Rc3/8 r Hexagon bushing Stainless steel HRLE090/050 Rc3/8 x Rc1/4 2 For CH1/CH2 t Pressure gauge — HRLE090/050 R1/4 2 For CH1/CH2 y Nipple Stainless steel HRLE090/050...
* This is the calculated value by changing the fluid temperature only. cool 32°C down to 20°C. Thus, it varies substantially depending on the water bath or piping shape. HRLE090-A Precautions on Cooling Capacity Calculation 1. Heating capacity When the circulating fluid temperature is set above room temperature, it needs to be heated by the thermo-chiller. The heating capacity depends on the circulating fluid temperature.
HRLE Series Specific Product Precautions 1 Be sure to read this before handling the products. Refer to the back cover for safety instructions. For temperature control equipment precautions, refer to the “Handling Precautions for SMC Products” and the “Operation Manual” on the SMC website: https://www.smcworld.com Design Operating Environment / Storage Environment Warning...
Page 36
Weight [kg] Dimensions [mm] HRLE050-A-20 HRLE050-W-20 Height 1320 x Width 580 x Depth 1240 HRLE090-A-20/40 HRLE090-W-20/40 2. Transporting with forklift 1. A licensed driver should drive the forklift. 2. Insert the fork to the place specified on the label. The fork should reach through to the other side of the product.
Page 37
1000 1500 2000 3000 4000 Current (% to the capacity of the main breaker of this product) 3. When deionized (pure) water is used, the electric conductivity should be 0.5 μS/cm or higher (Electric resistivity: 2 MΩ·cm or lower). HRLE090...
Page 38
<Heat radiation amount / Facility water specifications> Model Heat radiation [kW] Facility water specifications Refer to “Facility water system” in the HRLE050-W-m-m Approx. 10 specifications on page 9-1. Refer to “Facility water system” in the HRLE090-Wm-m Approx. 20 specifications on pages 10 and 12. 28-1...
Page 40
HRLE Series Specific Product Precautions 4 Be sure to read this before handling the products. Refer to the back cover for safety instructions. For temperature control equipment precautions, refer to the “Handling Precautions for SMC Products” and the “Operation Manual” on the SMC website: https://www.smcworld.com Facility Water Supply Operation Restart Time / Operation and Suspension Frequency Warning...
Page 41
HRLE Series Specific Product Precautions 5 Be sure to read this before handling the products. Refer to the back cover for safety instructions. For temperature control equipment precautions, refer to the “Handling Precautions for SMC Products” and the “Operation Manual” on the SMC website: https://www.smcworld.com ...
Page 42
These safety instructions are intended to prevent hazardous situations and/or Safety Instructions equipment damage. These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.” They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC), and other safety regulations.
Need help?
Do you have a question about the HRLE090 and is the answer not in the manual?
Questions and answers