Download Print this page
Black Box EME1TH00C User Manual
Black Box EME1TH00C User Manual

Black Box EME1TH00C User Manual

Dual temp/humidity sensors

Advertisement

Quick Links

USER MANUAL
EME1TH00C
DUAL TEMP/
HUMIDITY
SENSORS
24/7 TECHNICAL SUPPORT AT 1.877.877.2269 OR VISIT BLACKBOX.COM

Advertisement

loading

Summary of Contents for Black Box EME1TH00C

  • Page 1 USER MANUAL EME1TH00C DUAL TEMP/ HUMIDITY SENSORS 24/7 TECHNICAL SUPPORT AT 1.877.877.2269 OR VISIT BLACKBOX.COM...
  • Page 2: Chapter 1: Introduction

    1.877.877.2269 1.1 INTRODUCTION The EME1TH00C NIST2 sensors feature two NIST traceable, calibrated temperature sensors and an internal calibration integrity check. With this technology, the sensors operate in pairs, with the values compared once a second. If a difference greater than the stated tolerance of the sensor is detected, an alarm is raised to warn that the sensor is out of calibration.
  • Page 3 1.877.877.2269 1.2 NIST SENSOR COMPATIBILITY The EME1TH00C NIST2 sensor is compatible with the AlertWerks Plus Gateways with F7 and H7 processors. The NIST2 sensors will not work on the older AlertWerks Plus Gateways with F4 processors. The NIST2 sensors are compatible with the AlertWerks V4E and V4EL Gateways, but they are not supported on the 8-port sensor expansion modules.
  • Page 4: Chapter 2: Specifications

    NEED HELP? LEAVE THE TECH TO US LIVE 24/7 TECHNICAL CHAPTER 2: SPECIFICATIONS SUPPORT 1.877.877.2269 TABLE 2-1. SPECIFICATIONS SPECIFICATION DESCRIPTION Temperature Celsius Measurement range -55 to +75° C Celsius Measurement resolution 1° C Celsius Measurement accuracy ±0.2°C accuracy from -10 to +75° C Fahrenheit Measurement range -67 to +167°F Fahrenheit Measurement resolution...
  • Page 5 SUPPORT 1.877.877.2269 3.1 OPERATION After plugging the EME1TH00C NIST2 sensor into a sensor port on the Gateway, the following sensors will be shown on the unit: 3.1.1 TEMPERATURE SENSOR The Temperature sensor uses value averaging from the NIST calibrated temperature sensors for the displayed value.
  • Page 6 NEED HELP? LEAVE THE TECH TO US LIVE 24/7 TECHNICAL CHAPTER 3: OPERATION SUPPORT 1.877.877.2269 Figure 3-2 below shows sensor port information: FIGURE 3-2: SENSOR PORT INFORMATION 3.1.5 RE-CALIBRATION DETAILS If the NIST sensors are detected as out of calibration, they can be replaced, or they can be re-calibrated. There is also an offset setting in the web UI that can be used to offset the value.
  • Page 7 NEED HELP? LEAVE THE TECH TO US LIVE 24/7 CHAPTER 3: OPERATION TECHNICAL SUPPORT 1.877.877.2269 From the page shown in Figure 3-3, you can view and configure the sensor options. Sensor Name The sensor can be named as needed for the application. Status When communication with the temperature sensor is lost, the status of the temperature sensor is changed to sensorError.
  • Page 8 NEED HELP? LEAVE THE TECH TO US LIVE 24/7 TECHNICAL CHAPTER 3: OPERATION SUPPORT 1.877.877.2269 3.1.7 ADVANCED TAB Figure 3-5 below shows options on the Advanced Tab. FIGURE 3-5: ADVANCED TAB OPTIONS Degree Type The Degree Type can be set to Fahrenheit or Celsius. The system stores the thresholds for both Celsius and Fahrenheit independently, allowing you to switch between the two degree types.
  • Page 9 NEED HELP? LEAVE THE TECH TO US LIVE 24/7 CHAPTER 3: OPERATION TECHNICAL SUPPORT 1.877.877.2269 Calibration Factor This is a Calibration tool. If you wish to calibrate the temperature sensor, for example, you could enter an offset value of 5. In this example, if the sensor reads 20 degrees then it would record as 25 degrees.
  • Page 10 NEED HELP? LEAVE THE TECH TO US LIVE 24/7 TECHNICAL CHAPTER 3: OPERATION SUPPORT 1.877.877.2269 Filter Status The Sensor Filter Status is a feature that you can Enable or Disable. When enabled, it will check the sensor status. If the status of the sensor changes very rapidly, it will report how many times the sensor status changed, instead of having multiple separate entries in the syslog.
  • Page 11 NEED HELP? LEAVE THE TECH TO US LIVE 24/7 CHAPTER 3: OPERATION TECHNICAL SUPPORT 1.877.877.2269 3.1.9 NIST2 SENSORS ON THE ALERTWERKS V4E AND V4EL The NIST2 sensors feature two NIST-traceable, calibrated temperature sensors. With our provided Virtual Sensor script, users can set customizable thresholds to raise an alarm to warn that the sensor is out of calibration.
  • Page 12 SUPPORT 1.877.877.2269 Contact Black Box Support to download both scripts in a compressed file format (ZIP). NOTE: These script files are also included at the end of this manual. To create a Custom Script Virtual Sensor for the Value averaging script: Access the Virtual Sensor setting page via Sensor =>...
  • Page 13 NEED HELP? LEAVE THE TECH TO US LIVE 24/7 CHAPTER 3: OPERATION TECHNICAL SUPPORT 1.877.877.2269 Click on “Add Your Own Script.” Figure 3-10 shows the “Add Your Own Script” button. FIGURE 3-10: ADD YOUR OWN SCRIPT BUTTON HIGHLIGHTED In the popup window, click Choose File => Browse to the script => Add File => Close Figure 3-11 below shows the “Add File”...
  • Page 14 NEED HELP? LEAVE THE TECH TO US LIVE 24/7 TECHNICAL CHAPTER 3: OPERATION SUPPORT 1.877.877.2269 Sensor Name Configure the sensor name as desired. Script Name Select the desired script. Script Parameters Set the sensor port where you plugged in the NIST2 sensor. Sensor Style Analog Value Factor...
  • Page 15 NEED HELP? LEAVE THE TECH TO US LIVE 24/7 CHAPTER 3: OPERATION TECHNICAL SUPPORT 1.877.877.2269 Figure 3-13 below shows the sensor threshold screen: FIGURE 3-13: SENSOR THRESHOLDS SCREEN Configure the Virtual Sensor execution settings as shown in Figure 3-14 below: FIGURE 3-14: SENSOR EXECUTION SETTINGS NOTE: The Minimum Polling Interval of the Virtual Sensor is 5 seconds.
  • Page 16 NEED HELP? LEAVE THE TECH TO US LIVE 24/7 CHAPTER 4: REFERENCE TECHNICAL SUPPORT 1.877.877.2269 Note: In case of “sensor error” reading, the NIST2 scripts display an error in the following format: Error Message: NIST2 sensors on RJ45 port {Port} have invalid status ({MainSensorStatus}, {BackupSensorStatus}) EXAMPLE: “NIST2 sensors on RJ45 port 6 have invalid status (7, 7)”...
  • Page 17 NEED HELP? LEAVE THE TECH TO US LIVE 24/7 CHAPTER 4: REFERENCE TECHNICAL SUPPORT 1.877.877.2269 else echo “NIST2 sensors on RJ45 port $PORT have invalid status ($T1_STATUS, $T2_STATUS)”; # Output error message to “Error Message” section on the Virtual Sensor setting page. exit 1;...
  • Page 18 NEED HELP? LEAVE THE TECH TO US LIVE 24/7 NOTES TECHNICAL SUPPORT 1.877.877.2269 1.877.877.2269 BLACKBOX.COM...
  • Page 19: Appendix A: Regulatory Information

    NEED HELP? LEAVE THE TECH TO US LIVE 24/7 APPENDIX A: REGULATORY INFORMATION TECHNICAL SUPPORT 1.877.877.2269 A.1 FCC STATEMENT This equipment has been tested and found to comply with the regulations for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 20 NEED HELP? LEAVE THE TECH TO US LIVE 24/7 TECHNICAL APPENDIX A: REGULATORY INFORMATION SUPPORT 1.877.877.2269 A.4 NOM STATEMENT 1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado. 2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura. 3.
  • Page 21: Appendix B: Disclaimer/Trademarks

    B.1 DISCLAIMER Black Box Corporation shall not be liable for damages of any kind, including, but not limited to, punitive, consequential or cost of cover damages, resulting from any errors in the product information or specifications set forth in this document and Black Box Corporation may revise this document at any time without notice.
  • Page 22 NEED HELP? LEAVE THE TECH TO US LIVE 24/7 TECHNICAL SUPPORT 1.877.877.2269 © COPYRIGHT 2021, 2022, 2023. BLACK BOX CORPORATION. ALL RIGHTS RESERVED. EN_IOT_MANUAL_EME1TH00C_REV1_2308.PDF...