Product implementation stardards:
EN 61010-1 :2010/A1:2019
EN 61010-2-011:2017
EN 61326-1 :2013
ULT FREEZER
Warning:
Before using this product,
please read this manual carefully
and keep it for future reference.
The design and specifications
are subject to change without
prior notice for product
improvement. Consult with your
dealer or manufacturer for
details.
version:002-6-2020
USER MANUAL
Model:VS-86L458
VS-86L568
VS-86L718
VS-86L838
EN

Advertisement

Table of Contents
loading

Summary of Contents for Vacc-Safe VS-86L458

  • Page 1 Product implementation stardards: EN 61010-1 :2010/A1:2019 EN 61010-2-011:2017 EN 61326-1 :2013 USER MANUAL ULT FREEZER Model:VS-86L458 Warning: Before using this product, please read this manual carefully VS-86L568 and keep it for future reference. The design and specifications are subject to change without...
  • Page 2: Table Of Contents

    Table of Contents Safety warnings ---------------------------------------- 1 Product Features -------------------------------------- 7 Precautions for Use ---------------------------------- 8 Product Installation -----------------------------------11 Product Components and Overview ------------- 12 Operating Instructions ------------------------------- 13 Alarm Description ------------------------------------ 15 Maintenance ------------------------------------------- 16 Troubleshooting and Repairs --------------------- 18 Specifications ---------------------------------------- Packing List ------------------------------------------- 20...
  • Page 3: Safety Warnings

    Safety warnings Safety Warning Signs Watch Your Electrocution Combustible Warning Hand Hazard! Material WARNING: The packaging base at the bottom of this series of products must be removed before use. WARNING: When moving this series of products, take care that the bottom foot does not touch the power cord.
  • Page 4 WARNING: In case of leakage of gas and other flammable gases, open the doors and windows to ventilate and exhaust gas. Do not plug or unplug the power plug of the ULT freezer, otherwise it may cause an explosion and fire. WARNING: Only professional technicians or maintenance personnel for after-sales support can disassemble and assemble the ULT freezer.
  • Page 5 The disposal of the ULT freezer shall be accomplished by the appropriate personnel. Remove doors to prevent accidents such as suffocation. WARNING: If CO standby system is used, a good ventilation environment must be provided at the installation and use site. WARNING: Increased carbon dioxide concentrations in the air can asphyxiate and endanger life safety.
  • Page 6 WARNING: It is not allowed to tie, drag, pull, wind and bind the power cord, or damage the power cord plug. Damaged power cords or plugs may cause fire or electric shock. WARNING: The power cord with a loose plug is not allowed, because it may cause fire or electric shock.
  • Page 7 dangerous goods and strong corrosive acid, alkali and other items; The keys of this series of products need to be properly stored to avoid  accidents when children get them and open the door to play; Do not connect the neutral wire (N terminal) and the ground wire (E terminal) of ...
  • Page 8 freezer or personnel injuries. Do not use electrical appliances inside the storage compartment of the ULT  freezer, unless they are of the type recommended by the manufacturer.
  • Page 9: Product Features

    Product Features This product is mainly used to preserve drugs, vaccines and reagents. It is applicable to hospitals, epidemic prevention stations, universities, scien - tific research institutes and electronic chemical industry enterprise labs. Product Function Precision temperature control Data traceability •...
  • Page 10: Precautions For Use

    Precautions for Use ★ When the ULT freezer is running, the contact part between the front of the ULT freezer and the outer door may be heated, which is not a fault. In order to prevent condensation around the ULT freezer housing, the heating condensate pipe is installed.
  • Page 11: Product Installation

    Product Installation Installation Environment ★ Ambient temperature: 10 °C~32 °C; ideal temperature: 18 °C~25 °C; air conditioning system shall be used if necessary. ★ Ambient humidity: less than 80%Rh. The humidity shall be less than 60% Rh if the maximum operating temperature is 32 °C. ★...
  • Page 12 ★ As the ambient temperature has a great impact on the CAUTION equipment, if the above environmental requirements cannot be met, the equipment may not operate normally. Please improve the environment before using the equip- ment. The equipment operates intermittently. Preparation before Use 1 Remove all transport packaging materials and belts.
  • Page 13 Operation after Power Failure The set value is memorized by the equipment. After recovery from a power failure, the equipment will resume operation with the setting parameters be- fore the power failure. ★ If the ULT freezer is unplugged or the power to the ULT WARNING freezer is interrupted, do not restart the ULT freezer for at least 5 minutes to avoid damage to the compressor or...
  • Page 14: Product Components And Overview

    Product Components and Overview Schematic diagram of appearance Door Control panel Exterior door handle Universal wheel Due to the improvement of products and different models, the actual products may be different from the schematic diagrams. The actual configuration will depend on the physical product. The schematic diagrams are only for the description of functional parts.
  • Page 15: Operating Instructions

    Operating Instructions Display panel Description of buttons and icons Button 1 - Up; Button 2 - Down; Button 3 - Setup/Mute. Icon 4 - 485 communication; Icon 5 - Button locking; Icon 6 - Compressor startup; Icon 7 - Power-on; Icon 8 - Door opening; Icon 9 - Alarm silence; Icon 10 - Abnormal power supply;...
  • Page 16 4. Parameter setting When the button is not locked, press and hold the Setup/Mute button for 3s, and the digital tube displays "PS1". Press the Setup/Mute button to switch the menu and corresponding parameters, and press the Up and Down buttons to select the menu or adjust the parameters.
  • Page 17: Alarm Description

    5. Export of USB temperature data the data of the current and the last months will be generated and imported will buzz once, the screen will display "End" and return to normal display after Alarm Description Alarm Meaning Triggering conditions codes An audible and visual alarm is given when the temperature Alarm for high temperature...
  • Page 18: Maintenance

    Maintenance WARNING ★ Always cut off the power supply before any repair and maintenance of the equipment to prevent electric shocks or personnel injuries. ★ Make sure that drugs or suspended particles from the surrounding envi- ronment will not be inhaled during equipment maintenance. Otherwise it may cause harm to human health.
  • Page 19 Inner wall defrosting Frosting may cause a gap between the ULT freezer and the door sealing strip, resulting in poor refrigeration. The inner door shall be defrosted with an ice shovel attached to the ULT freezer. The following steps are natural de- frosting.
  • Page 20: Troubleshooting And Repairs

    Model VS-86L458 VS-86L568 VS-86L718 VS-86L838 Matched freezer racks size 140*549*293 140*685*293 140*685*293 140*685*293 (single) mm Number of racks/drawers/hanging baskets Number of inner doors Number of freezer racks placed Number of cryo boxes Troubleshooting and Repairs Any product may suffer a failure. Please observe the equipment operation during use.
  • Page 21: Specifications

    Name ULT freezer Model VS-86L458 VS-86L568 VS-86L718 VS-86L838 Climate type 16~32°C Electrical shock pro- Class I tection class Electricity 220V~240V/50Hz Temperature inside (-86~-40)°C the box Refrigerant Mixed refrigerant Refrigeration meth- Direct cooling Foam material Cyclopentane Total effective vol- 458L 568L...
  • Page 22: Packing List

    Packing List Handle Defrosting Name Manual (Based on (Based on shovel Quantity Note: External padlock and handle optional accessories shall be subject to Electrical Schematic Diagram VS-86L458 LED Light Display Control Panel Balance port USB memory of heater board PT1000 Battery...
  • Page 23 VS-86L568 LED Light Display Control Panel Blance port USB memory of heater board PT1000 Battery VS-86L838 Display LED Light Control Panel Balance port USB memory of heater board PT1000 Compressor 1 Compressor 2 Battery Inverter 1 Inverter 2...
  • Page 24: Service Guide

    Service Guide Precautions 1 This Warranty Card is properly kept by the customer and serves as a war- ranty certificate for the product together with the purchase invoice. 2 Since the date of purchase, failures caused by product manufacturing quality without unauthorized disassembly and repair during the "Three Guarantees"...