Please read this manual completely before attempting to install or operate this equipment.
Notify carrier of damage! Inspect all components immediately.
IMPORTANT INFORMATION
READ BEFORE USE
PLEASE SAVE THESE INSTRUCTIONS!
3560 NW 56th Street
Fort Lauderdale, FL 33309
Tel.: 786.600.4687 / Toll Free: 844.218.8477
Fax.: 786.661.4100
5659 Royalmount Avenue
Montreal, Qc, Canada H4P 2P9
Tel.: 514.737.9701 / Toll Free: 888.275.4538
Fax.: 514.342.3854 / Toll Free: 877.453.8832

Advertisement

loading
Need help?

Need help?

Do you have a question about the Ikon IUC61R and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MVP Ikon IUC61R

  • Page 1 Pizza prep tables Sandwich/Salad Units Under-counter Refrigerators and Freezers Service, Installation and Care Manual Please read this manual completely before attempting to install or operate this equipment. Notify carrier of damage! Inspect all components immediately. IMPORTANT INFORMATION READ BEFORE USE PLEASE SAVE THESE INSTRUCTIONS! 3560 NW 56th Street 5659 Royalmount Avenue...
  • Page 2 Service and Installation Manual COMMERCIAL REFRIGERATOR SAFETY Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. Our product instructions will be uploaded on our company official website. This is the Safety Alert Symbol.
  • Page 3 Service and Installation Manual The key for appliance electric box should be safe kept by qualified persons in order to avoid a hazard WARNING: Keep ventilation openings, in the appliance enclosure or in the built-in structure, clear of obstruction. WARNING: Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer.
  • Page 4: Table Of Contents

    Service and Installation Manual CONTENTS RECEIVING & INSPECTING EQUIPMENT .................... 4 SPECIFICATIONS ............................5 INSTALLATION ..............................6 OPERATION ................................7 MAINTENANCE ............................9 WIRING DIAGRAM ........................11 All rights reserved. Reproduction of this manual without written permission is prohibited. SERIAL NUMBER INFORMATION The serial number of all self-contained refrigerators and freezers is located inside the unit on the left hand side near the top on the wall.
  • Page 5: Specifications

    Service and Installation Manual SPECIFICATION R-290 REFRIGERANT SANDWICH/SALAD UNITS FULL STORAGE SHELF SHIP LOAD CAPACITY CAPACITY CHARGE WEIGHT NEMA MODEL# V/Hz/Ph Size HP AMPS Cu-ft Sq-ft PLUG ISP29 115/60/1 5-15P 1365 ISP48 115/60/1 5-15P 11.5 1365 ISP61 115/60/1 5-15P 1365 13.1 ISP72 115/60/1...
  • Page 6: Installation

    Service and Installation Manual INSTALLATION Location Units represented in this manual are intended for indoor use only. Be sure the location chosen has a floor strong enough to support the total weight of the cabinet and contents. A fully loaded unit can weigh as much as 1500 pounds.
  • Page 7: Operation

    Service and Installation Manual OPERATION Do not throw items into the storage area. Failure to heed these recommendations could result in damage to the interior of the cabinet. CAUTION Refrigerated cabinets Temperature range for the internal cabinets is 33°F to 40°F for all food prep units, undercounter and worktop refrigerators, and -7°F to -3°F for undercounter and worktop freezers.
  • Page 8 Service and Installation Manual 1.1 Function of LEDS MAIN FUNCTIONS 2.1 HOW TO SEE THE SETPOINT 1. Push and immediately release the SET key: the display will show the set point value. 2. Push and immediately release the SET key or wait for 5 seconds to display the sensor value again.
  • Page 9: Maintenance

    Service and Installation Manual MAINTENANCE The power switch must be turned OFF and the unit disconnected from the power source whenever performing service, maintenance functions or cleaning the refrigerated area. DANGER Refrigerators and Freezers The interior and exterior can be cleaned using soap and warm water. If this isn't sufficient, try ammonia and water or a nonabrasive liquid cleaner.
  • Page 10 Service and Installation Manual MAINTENANCE Cleaning solutions need to be alkaline based or non-chloride based. Any cleaner containing chlorides will damage the protective film of the stainless steel. Chlorides are commonly found in hard water, salts, and household and industrial cleaners. If cleaners containing chlorides are used, be sure to rinse and dry thoroughly.
  • Page 11: Wiring Diagram

    Service and Installation Manual WIRING DIAGRAM MODEL: IUC27 PLUG DOOR OVERLOAD SWITCH PROTECTOR COMPRESSOR CONDENSER POWER THERMOSTAT DISPLAY CURRENT RELAY STARTING CAPACITOR EVAP ROOM EVAP SENSOR...
  • Page 12 Service and Installation Manual WIRING DIAGRAM MODEL: IUC48/IUC60 PLUG OVERLOAD DOOR PROTECTOR SWITCH CONDENSER COMPRESSOR THERMOSTAT DISPLAY POWER CURRENT RELAY STARTING EVAP CAPACITOR ROOM EVAP SENSOR MODEL: IUC72 PLUG OVERLOAD PROTECTOR THERMOSTAT DISPLAY CONDENSER COMPRESSOR DOOR SWITCH ROOM EVAP POWER SENSOR CURRENT RELAY...
  • Page 13 Service and Installation Manual WIRING DIAGRAM MODEL: IPP47 THERMOSTAT DISPLAY PLUG OVERLOAD PROTECTOR EVAP CIRCUITALION ROOM CONDENSER FAN MOTOR SENSOR FAN MOTOR COMPRESSOR t ℃ PTC STARTER MODEL: IPP71 THERMOSTAT DISPLAY OVERLOAD PLUG PROTECTOR EVAP ROOM SENSOR CIRCUITALION CONDENSER COMPRESSOR FAN MOTOR FAN MOTOR CURRENT...
  • Page 14 Service and Installation Manual WIRING DIAGRAM MODEL: IPP94 THERMOSTAT DISPLAY OVERLOAD PLUG PROTECTOR EVAP ROOM SENSOR COMPRESSOR CIRCUITALION CONDENSER FAN MOTOR FAN MOTOR CURRENT RELAY STARTING CAPACITOR MODEL: ISP29/ ISP29M THERMOSTAT DISPLAY PLUG OVERLOAD PROTECTOR EVAP ROOM CIRCUITALION SENSOR CONDENSER FAN MOTOR FAN MOTOR COMPRESSOR...
  • Page 15 Service and Installation Manual WIRING DIAGRAM MODEL: ISP48/ ISP61/ ISP48M/ ISP61M THERMOSTAT DISPLAY PLUG OVERLOAD PROTECTOR EVAP ROOM CONDENSER CIRCUITALION SENSOR FAN MOTOR FAN MOTOR COMPRESSOR t ℃ PTC STARTER MODEL: ISP72/ ISP72M THERMOSTAT DISPLAY OVERLOAD PLUG PROTECTOR EVAP ROOM CONDENSER CIRCUITALION SENSOR...
  • Page 16 Service and Installation Manual WIRING DIAGRAM MODEL: IUC28F PLUG THERMAL OVERLOAD CUT-OFF PROTECTOR DOOR COMPRESSOR SWITCH CONDENSER POWER THERMOSTAT DISPLAY EVAP CURRENT STARTING RELAY CAPACITOR ROOM EVAP SENSOR MODEL: IUC48F IUC61F PLUG THERMAL CUT-OFF OVERLOAD PROTECTOR DOOR SWITCH COMPRESSOR CONDENSER POWER THERMOSTAT DISPLAY STARTING...
  • Page 17 Service and Installation Manual WIRING DIAGRAM MODEL: IUC72F THERMAL OVERLOAD PLUG CUT-OFF PROTECTOR DOOR SWITCH COMPRESSOR CONDENSER POWER THERMOSTAT DISPLAY CURRENT STARTING RELAY CAPACITOR EVAP ROOM EVAP SENSOR...
  • Page 18 Service and Installation Manual WIRING DIAGRAM MODEL: IUC28...
  • Page 19 Service and Installation Manual WIRING DIAGRAM MODEL: IUC48/IUC61...
  • Page 20 Service and Installation Manual WIRING DIAGRAM MODEL: IUC72...
  • Page 21 Service and Installation Manual WIRING DIAGRAM MODEL: ISP29 / ISP29M...
  • Page 22 Service and Installation Manual WIRING DIAGRAM MODEL: ISP48 / ISP61 / ISP48M / ISP61M...
  • Page 23 Service and Installation Manual WIRING DIAGRAM MODEL: ISP72 / ISP72M...
  • Page 24 Service and Installation Manual WIRING DIAGRAM MODEL: IPP47...
  • Page 25 Service and Installation Manual WIRING DIAGRAM MODEL: IPP71...
  • Page 26 Service and Installation Manual WIRING DIAGRAM MODEL: IPP94...
  • Page 27 Service and Installation Manual WIRING DIAGRAM IUC28F MODEL:...
  • Page 28 Service and Installation Manual WIRING DIAGRAM MODEL: IUC28F...
  • Page 29 Service and Installation Manual WIRING DIAGRAM MODEL: IUC48F/IUC61F...
  • Page 30 MODEL: IUC72F WIRING DIAGRAM...
  • Page 31 IKON WARRANTY Two Year Parts & Labor Warranty MVP Group (IKON) warrants, to the original purchaser, all of its new equipment to be free from defects in material and workmanship, under normal use and maintenance service, for a period of two (2) years from the date of original purchase or 15 months after shipment date from the manufacturer, whichever occurs first.