Introduction

Operation principle

The optical smoke detector is especially suited for detecting
slow-starting fires that may smoulder for several hours before
breaking out. It is designed to protect the private areas of
buildings or apartment blocks and mobile homes.
It can be:
used as a stand-alone unit,
integrated into a Logisty alarm system with TwinPass
control panels L2302F, L3303F, L3305F and L3310F,
inter-connected in a wired network of up to 40 detectors.
In stand-alone mode, it produces the following alarms and
indications throughout the smoke detection period:
Red signal LED
indicates the state
of the detector
Detector transmit-
the LED flashes
ting the smoke
detection signal
Other wired
inter-connected
detectors
Connected to a Logisty alarm system it also activates imme-
diately smoke is detected:
triggering of the control panel siren and the alarm sirens in
fire alarm modulation for 5 minutes,
triggering of the telephone dialler.
It is recommended to replace the smoke detector
subject to a regular and normal maintenance
every 10 years. The replacement date is indicated
on back of the product.
67
White
indicator
LED
lit
quickly
-
lit
®
Built-in audible alarm
a built-in alarm sounds
on a continuous basis
(85 dB(A) at 3m)
a modulated built-in
audible alarm sounds
(85 dB(A) at 3m)
G
B

Advertisement

Table of Contents
loading

Summary of Contents for LOGISTY L3156X

  • Page 1: Table Of Contents

    (85 dB(A) at 3m) Indication ......76 Connected to a Logisty alarm system it also activates imme- Alerts........76 diately smoke is detected: Faults ........76 triggering of the control panel siren and the alarm sirens in Maintenance ....77 fire alarm modulation for 5 minutes, triggering of the telephone dialler.
  • Page 2: Description

    Introduction Power supply Description Connect the lithium battery respecting the polarity Red signal LED indicates the state of the detector The red indicator lamp flashes for 15 sec, then once every 10 sec, signalling the normal operation of the detector. Test key White indicator LED (an emergency LED is turned on in the event of smoke detection)
  • Page 3: Personalised Radio House/Site Code Programming

    Personalised radio house/site code programming Using the two programming buttons 0 and 1 enter your per- Checking the sonalised radio code to enable communication between the personalised radio code sensor and the other components of the system. Control panel in test mode (tamper sensor released).
  • Page 4: Installing The Detector

    Installing the detector Choosing the right place The detector must not be placed: directly on a metal surface, The detector must be placed: near fluorescent tubes, in rooms where there is a risk of fire (living in very dusty rooms, rooms with a fireplace, children’s bedrooms, in rooms where the temperature could lofts or basements that are occupied),...
  • Page 5: Testing The Radio Link At The Chosen Location

    Installing the detector Testing the radio Mounting link at the chosen Standard fixing method location Install the base in the desired location, then mark the posi- tion of the 2 fixing holes using a pencil (Ref. mark Drill holes using a 5 mm Ø drill bit. If you are adding Fix the base using appropriate pins and screw.
  • Page 6: Installing Several Detectors In A Network

    Installing the detector Align the 2 locating arrows Installing several detectors in a network marked on the mounting It is possible to inter-connect up to 40 detectors to enable base and the detector, then alarm activation over the whole range of smoke detectors of lock the unit by turning clock- the home.
  • Page 7: Detector Tests

    2 sec. For this type of test, the Connected to a Logisty system it activates immediately a button is pressed for 10s: detec tor’s responses are described in the “Detector triggering of the control panel siren and the alarm sirens in fire alarm modulation for 5 minutes, operation”...
  • Page 8: Manual Disabling Of The Detector

    Manual disabling of the detector It is possible to disable the detector for a 15 min period: prior to activities likely to produce smoke (sweeping of a dusty room, of a chimney…) and cause unwanted alarm acti- vation, to stop alarm in the event of detection of non-dangerous For the 15 min disable period, the detector smoke.
  • Page 9: Events Memory

    Events memory The sensor remembers the last event (trigger or error signal) To review the memory of events press the test button for two pips and release. The sensor recalls the last memorised event for 10 s. Red signal LED White indicates the state indicator...
  • Page 10: Indication

    Indication..Alerts ... Faults On the detector: In order not to wake you up, alarms resulting from mains To check which sensor has supply problems or dirty sensors are shut down during triggered the alarm consult the night. Any errors are corrected after daybreak within 10 minutes i.e.
  • Page 11: Maintenance

    Indication... Maintenance Indication of detection head clogging: Detector head maintenance When this problem arises, the detection head The regular maintenance of should be cleaned as quickly as possible the detector is of utmost (see Maintenance). importance. The detector head slots are to be vacu- Red signal LED White um-cleaned at least once a...
  • Page 12: Changing The Battery

    Maintenance Changing If the optional opening In case of any of the detector is the battery works in the room locked (see Fixing) If the optional opening Painting the detector is Insert a flat blade screw- prohibited. of the detector is driver into this notch.
  • Page 13: User Sheet

    User sheet (pull-out sheet for the user) Be prepared Summary of your detector’s responses and for a fire indications Plan an evacuation route. Normal operation Prepare an evacuation Red signal LED White plan for every bedroom. indicates the state indicator Built-in audible alarm The least smoke is near of the detector...
  • Page 14 User sheet (pull-out sheet for the user) Battery fault indication To prevent users from being dis- turbed at inconvenient times, Red signal LED White audible indications of a battery indicates the state indicator Built-in audible alarm of the detector fault or dirt on the detection head can be delayed for 8 hours over a Detector at the source the unit flashes once...
  • Page 15: Technical Data

    To obtain advice when installing your system or before returning equipment, please contact the LOGISTY technical support team (see telephone number at the back of the alarm system installation manual) or www.logistysupport.co.uk. A team of qualified technicians will tell you what to do.
  • Page 16 Address: Gutemberg-Str, 7, 65719 Hofheim-Wallau Product type: Residential radio smoke detector Trade mark: Logisty We declare under our sole responsibility that the products to which this declaration relates are thus compliant with the essential requirements of the following European Directives: •...

Table of Contents