8.2

IGT-34C

8.2.1

Mode of Current Input

There are four 16-bit isolated current inputs for IGT-34C.The current inputs are designed
for 4-20 mA. You can switch the measure range and data format by software.
Input range
Data format
8.2.2

Wiring of Current Input

IGT-34C support 4-ch 4~20mA / 0-20mA current input, the following figure shows how to
wire in the current input channels.
IGT-30 Series
Range description
4~20 mA (default)
0~20 mA
0~65536 -32768~32767
Decimal
58
Note
Switch by IGT_AI_Config
The unit of decimal format
is mA.