Chalmit Curie Elite ATEX Installation, Operation And Maintenance Instructions

Ip65 recessed led luminaires

Advertisement

Quick Links

Curie Elite
IP65 Recessed LED Luminaires
ATEX, IECEx and UKEX
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
Important:
Please read these instructions carefully before installing or maintaining this equipment.
Good electrical practices should be followed at all times and this data should be used
as a guide only.
I-CUEE-03.doc
Luminaire Dimensions
A
/MST
547
547
/MET
572
572
STANDARD
572
572
Issue 09
IOM – CURIE ELITE - ZONE 1 RECESSED
B
C
D
E
500
500
599
500
500
624
500
500
644
28/04/2021
F
G
599
135
624
135
644
135
1

Advertisement

Table of Contents
loading

Summary of Contents for Chalmit Curie Elite ATEX

  • Page 1 IOM – CURIE ELITE - ZONE 1 RECESSED Curie Elite IP65 Recessed LED Luminaires ATEX, IECEx and UKEX INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Important: Please read these instructions carefully before installing or maintaining this equipment. Good electrical practices should be followed at all times and this data should be used as a guide only.
  • Page 2: Specification

    IOM – CURIE ELITE - ZONE 1 RECESSED 0.0 Specification Type of Protection Ex eb mb op is qb Increased safety, Encapsulation, optical radiation, powder filling. (With isolating switch: Ex db eb mb op is qb Flameproof is added) Protection Standards (IEC) EN 60079-0, (IEC) EN 60079-1, (IEC) EN 60079-5, (IEC) EN 60079-7, (IEC) EN 60079-18, (IEC) EN 60079-28, (IEC) EN 60079-31 Area Classification...
  • Page 3 IOM – CURIE ELITE - ZONE 1 RECESSED The luminaire can be installed to interface with fire resistant ceiling systems to maintain a B15 B15 SOLAS SOLAS fire rating; the integrity of the ceiling and insulation must be maintained using suitable insulation materials.
  • Page 4 Chemical compatibility is highly dependent on concentration, temperature, humidity and other environmental conditions. The end use will assume responsibility for evaluation of gaseous or direct contact compatibility at their site prior to product installation. If in doubt please contact Chalmit sales. The luminaire is tested to EN 60598-1.
  • Page 5: Electrical Supplies

    IOM – CURIE ELITE - ZONE 1 RECESSED The information in this leaflet is correct at the time of publication. The company reserves the right to make specification changes as required without notice. 3.1.1 Use in Combustible Dust Atmospheres Where the equipment is used in combustible dust atmospheres, reference must be made to the selection and installation standards in order that the equipment is used correctly.
  • Page 6: Led Display

    IOM – CURIE ELITE - ZONE 1 RECESSED Suspension mount holes: If using the 4 additional suspension mount holes on the rear of the fitting, please ensure the sealing washers are fitted and torqued to a value of 2.5Nm. 3.5 Cabling and Cable Glands The temperature conditions at the supply cable entry point are such that 70ºC (ordinary PVC) cable can be used.
  • Page 7: Routine Maintenance

    IOM – CURIE ELITE - ZONE 1 RECESSED 5.0 Servicing and Operation Safe servicing behind the gear tray requires the mains supply to be isolated. 5.1 Opening and Closing front cover. The front cover is secured using up to 10 off M6 captive screws.
  • Page 8: Battery Disposal

    IOM – CURIE ELITE - ZONE 1 RECESSED 6.1 Cleaning The body of the luminaire may be cleaned with a mild solution of household detergent and water, after cleaning the body should be washed and wiped with clean water. The diffuser should not be polished or wiped with a dry cloth as a risk of ignition due to electrostatic discharge may result.
  • Page 9 IOM – CURIE ELITE - ZONE 1 RECESSED EU/UK-Declaration of conformity UE-Déclaration de conformité EU-Konformitätserklärung Manufacturer Chalmit Address 388 Hillington Road, Glasgow. G52 4BL Scotland UK Product Curie Elite (LED) Emergency Luminaire. Notified Body CML B.V. 2776 EU Type Examination Certificate...
  • Page 10 Dieser Strahler widersteht Überspannungen bis 400V AC 1 Minute lang sowie Stoßspannungen von 4kV. On behalf of the Chalmit, I declare that, on the date the equipment accompanied by this declaration is placed on the market, the equipment conforms to all technical and regulatory requirements of the above listed directives.