3Portable Compressed Air Filter and FOR MORE INFORMATION Regulator Panel 256-02-00, with In United States, contact: Carbon Monoxide Filtration Internet: www.3M.com/occsafety Technical Assistance: 1-800-243-4630 and Monitor For other 3M products: 1-800-3M-HELPS or 1-651-737-6501 User Instructions (Keep these User Instructions for reference) In Canada, contact: Internet: www.3M.com/CA/occsafety...
– General Description SPECIFICATIONS – 3M Respirator Capacity – Discussion on Respirable Air PRODUCTS, ACCESSORIES AND PARTS – 3M™ Portable Compressed Air Filter and Regulator Panel 256-02-00, with Carbon Monoxide Filtration and Monitor – Replacement Parts – Accessories – Set Up Procedures OPERATING INSTRUCTIONS –...
To meet NIOSH requirement 42 CFR 84, subpart 84.150 for minimum and maximum airflow – Air flow into the respirator is reduced or stops. (4-15 cfm, 113-425 lpm), the air control valves approved for use with the 3M respirators must – Breathing becomes difficult.
5 ppm Canada). maximum airflow consumption, supply pressure ranges, and approved hose lengths as stated in the User Instructions for the 3M air control device to determine the number of respirators of a specific type that may be connected to the panel.
To meet NIOSH requirement 42 CFR 84, subpart 84.150 for minimum and maximum airflow 5 Prefilter 18 Tubing St. Elbow (2 each) (4-15 cfm, 113-425 lpm), the air control valves approved for use with the 3M respirators must 6 Tube Locking Collar 19 Tubing be operated within the supply pressure ranges and hose lengths stated in their User Instructions.
Set Up Procedures W WARNING The 3M filter and regulator panel, with CO filtration when used in accordance with the following instructions, will remove or reduce selected contaminants from compressed air lines. (Fig. 4) The intrinsic safety of the carbon monoxide monitor is voided when remote alarm is used.
Air supply piping, fittings, and compressors must have the capacity to deliver sufficient air The following instructions are intended to serve as a guideline for the use of the 3M™ Portable volume to operate each air regulating valve at the recommended pressure.
To meet NIOSH requirement 42 CFR 84, subpart 84.150 for minimum and maximum airflow (4-15 cfm, 113-425 lpm), the air control valves approved for use with the 3M respirators must be operated within the supply pressure ranges and hose lengths stated in their User Instructions.
O-ring. HAND TIGHTEN ONLY! 9. Guide drain tube back through hole in bottom of case. Always turn off air supply and bleed air pressure before disassembling the 3M filter and Air Scrubber-Third and Fourth Stages regulator panel with CO filtration or serious injury could result.
(1) and two (2) year periods respectively. 3M shall not be liable for loss of use of any of its products or incidental or consequential costs, expenses, or damages incurred by the purchaser or any other user.