Table of Contents • Components and Features • How To Use Your Appliance • Cleaning And Mainteniance • Practical Advice • Safety is a Good Habit to Get Into • Is there a problem? • Installation Instructions for Built-In • Gas Connection •...
Components and Features A. Brass Gas Burner Cap B. Support Grid for Cookware C. Control Knobs for Gas Burners D. Heat Refector E. Small Support Grid Technical Features V7828MHR Model No. 37mbar Inlet Pressure 4.5kW. 4.5kW. Power - 3 / EN -...
How To Use Your Appliance The position of the corresponding gas burner is indicated on each control knob. Gas Burners The burners differ in size and power. Choose the most appropriate one for the diameter of the cookware being used. The burner can be regulated with the corresponding control knob by using one of the following settings: Inner and outer flame on minimum power...
Cleaning and Mainteniance Before cleaning or performing maintenance on your appliance, disconnect it from the electrical power supply. To extend the life of the cooktop, it is absolutely indispensable that it be cleaned carefully and thoroughly on a frequent basis, keeping in mind the following: •...
Practical Advice Practical Advice on Using the Burners For best performance, follow these general guidelines: • Use the appropriate cookware for each burner (see table) in order to prevent the flame from reaching the sides of the pot or pan; •...
Page 22
The following should be avoid: • Touching the appliance with wet parts of the body; • The hotplates and their immediate vicinity get very hot. Never touch the hot surfaces. • Improper and/or dangerous use; • Obstructing the ventilation or heat dissipation slots; •...
Is there a problem ? It may occur that the cooktop does not function or does not function properly. First of all, check to see that there are no interruptions in the gas and electrical supplies, and, in particular, that the gas valves for the mains are open. The burner does not light or the flame is not uniform around and burner.
Installation Instructions for Built-In The following instructions are intended for the installer so that the installation and mainte- nance procedures may be followed in the most professional and expert manner possible. Important : Disconnect the appliance from the electrical supply before performing any maintenance or regulation upkeep work.
Page 25
2) The room must also allow for the influx of the air needed for proper combustion. The flow of air for combustion purposes must not be less than 2m 3 /h per kW of installed capacity. The supply of said air can be effected by means of direct influx from the outside through a duct with a inner cross section of at least 100 cm 2 which must not be able to be accidental- ly blocked.
Page 26
4) Liquefied petroleum gases are heavier than air and, as a result, settle downwards. Rooms in which LPG tanks are installed must be fitted with ventilation openings to the outside in order to allow the gas to escape in the event of a leak. Therefore, LPG tanks, whether empty or partially full, must not be installed or stored in rooms or spaces below ground level (cellars, etc.).
Page 27
D) The dimensions of the cutout for the appliance must be those indicated in the figure D. Clamps are provided to fasten the cooktop to counters measuring from 20 to 60 mm in thickness. To fasten the cooktop securely, it is recommended that all the clamps be used.
Page 28
E. The hob can only be installed above built-in ovens provided with cooling ventilation. Important : When installing the cooktop above a built-in oven, the oven should be placed on two wooden strips; in the case of a joining cabinet surface, remember to leave a space of at least 4-5 cm.
Gas Connection This appliance is not connected to a combustion products evacuation device. It shall be installed and connected in accordance with current installation regulation. Particular attention shall be given to the relevant requirement regarding ventilation. The cylinder should be placed in a well-ventilated location and not exposed directly to the sun or other heat sources.
37 mbar or 0.5 psi Recommended Component: Gas Low Pressure Regulator MEX Model SPR37S, use with gas cylinder, outlet pressure at 37 mbar TISII STANDERD Certificate No: 805-2540 How to load battery (on those models fitted with battery box)
REPAIR Please return the appliance to seller or call the qualified person for repair and spare parts. Do not repair it by yourself. Service Center : Tel. 02-493-6565 TROUBLE SHOOTING Trouble phenomenal Reasons Solutions The main gas valve not opened Open the main gas valve Jet blocked Dredge the jet...
Page 32
PEN K INTER TRADING CO., LTD. HEAD OFFICE : 1000/63-64 PB TOWER. 16th Floor. Sukhumvit 71 Road, North Klongtan,Wattana, Bangkok 10110 TEL. 0-2493-6565 FAX : 0-2391-1141 SERVICE CENTER : 63/3 Moo 6 Soi Suksawat 76, Bangchak, Phra Pradaeng, Samut Prakan 10130 TEL.
Need help?
Do you have a question about the V7828MHR and is the answer not in the manual?
Questions and answers