WARNING! To prevent serious injury DO NOT use damaged equipment. If abnormal noise or vibration occurs have the problem
corrected.
5.2.
BEFORE FIRST USE
5.2.1.
Before operating the press, purge the hydraulic system, in order to eliminate any air that may have accumulated during transit.
Open the release valve and pump the handle several times and close the release valve. Should the system malfunction at any time,
repeating this process may resolve the problem.
DANGER! This model is purposefully designed to withstand greater loads than the hydraulic units can develop. For safety reasons,
always ensure the work-piece and press tools are secured on the table and will not flex or suddenly "give way" causing danger to
operator or the component. Also ensure you have read and understood chapter 1 safety instructions.
6. OPERATION
6.1.
Check that the hydraulic unit is fully closed ready for operating.
6.1.1.
Position the table at the required operating height by inserting the pins into the appropriate holes in the frame.
6.1.2.
Position the arbor plates or press tools to be used onto the table and align beneath the ram. Place work-piece onto the table or arbor
plates and align beneath the ram as required. Note: Care must be taken to ensure that the arbor plates do not fall from the press table.
If necessary hold the configuration in position with clamps (not supplied).
6.1.3.
Operate the pump slowly until the ram is close to or just touching the work-piece. Before applying real pressure to the work-piece
recheck the alignment with the ram and ensure that the work-piece and press tools are supported in such a way that they cannot flex to
breaking point. DO NOT exceed the stroke indicated on the label or the red mark on the piston and DO NOT apply off centre loads.
6.1.4.
When work is complete release the pressure by fitting the handle over the release valve and turning anti-clockwise in small increments.
6.1.5.
Once the hydraulic unit has been fully retracted, remove the work-piece from the arbor plates and the table.
Note: Always keep the piston retracted after use to avoid corrosion.
7. MAINTENANCE
7.1.
Note: Maintenance and repair must only be carried out by qualified person. Contact your Sealey stockist for details.
7.2.
When the press is not in use, the hydraulic unit ram must be fully retracted to minimise corrosion. Remove the handle to inactivate the
press.
7.3.
Lubricate all moving parts at regular intervals.
7.4.
Always keep the press clean, dry, and protected from harsh conditions.
7.5.
Should you need to replace the oil, ensure the hydraulic unit ram is fully retracted. An excess of oil will render the press inoperative.
Use only appropriate Sealey hydraulic jack oil (Sealey Part Number: HJO500MLS/HJO5LS). DO NOT use brake fluid.
Purge the system to remove any air.
7.6.
Check your model parts information for spares.
IMPORTANT: NO RESPONSIBILITY IS ACCEPTED FOR INCORRECT USE OF THE MACHINE.
Hydraulic products are only repaired by local service agents. We have service/repair agents in all parts of the UK.
DO NOT RETURN PRODUCT TO US. Please telephone us on 01284 757500 to obtain the address and phone number of your local
stockist.
If product is under guarantee please contact your dealer.
De-commissioning Product
Should the product become completely unserviceable and require disposal, draw off the oil into an approved container and dispose of
the product and the oil according to local regulations.
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted,
taken to a recycling centre and disposed of in a manner which is compatible with the environment. When the product
becomes completely unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and
dispose of the product and fluids according to local regulations.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
© Jack Sealey Limited
sales@sealey.co.uk
Original Language Version
REGISTER YOUR
PURCHASE HERE
www.sealey.co.uk
YK12F. Issue 1 10/01/23

Advertisement

loading