Triaxial mems dc accelerometer, 675 mv/g, 2 g, single-ended, 10 ft integral cable (12 pages)
Summary of Contents for PCB Piezotronics 3713B112G
Page 1
Model 3713B112G Triaxial DC Response Accelerometer Installation and Operating Manual For assistance with the operation of this product, contact PCB Piezotronics, Inc. Toll-free: 800-828-8840 24-hour SensorLine: 716-684-0001 Fax: 716-684-0987 E-mail: info@pcb.com Web: www.pcb.com...
Page 2
Returning Equipment – Following the equipment to PCB Piezotronics for these procedures will insure that your repair. User servicing or repair is not returned materials are handled in the recommended and, if attempted, may most expedient manner.
Page 3
PCB Piezotronics, Inc. Warranty – All equipment and repair 3425 Walden Ave. services provided by PCB Piezotronics, Depew, NY 14043 USA Inc. are covered by a limited warranty Toll-free: (800) 828-8840 against defective...
3710 series DC Accelerometer Operating Guide Introduction Principle of Operation This operating guide contains information that will familiarize the user with the basic operation and installation of the 3710 The sensor element of the 3710 series features a proof mass, Series MEMS DC Accelerometers.
3710 series DC Accelerometer Operating Guide Typical Measurement System Easy Mount Clip: Recommended when frequent installation and removal of Series 3710 series accelerometers is desired. The 3710 series DC Accelerometers are available in a uniaxial The Easy-Mount Clip can either be stud mounted or adhesive- or triaxial package, with the uniaxial model being the 3711 ly mounted to the test structure.
Page 6
3710 series DC Accelerometer Operating Guide 10.0 Maintenance and Repair If the sensor is extended, in the case of an integral cable sensor, or a cable length other than 10 ft is used, in the Because of the sophisticated nature of PCB instrumentation, case of sensor with an integral connector, the offset volt- age will change.
Page 7
Model Number Revision E TRIAXIAL DC RESPONSE ACCELEROMETER 3713B112G ECN #: 36673 Performance ENGLISH Optional Versions (Optional versions have identical specifications and accessories as listed Sensitivity (±5 %) 1000 mV/g 101.9 mV/(m/s²) for standard model except where noted below. More than one option maybe used.) Measurement Range ±2 g pk...
Page 10
PCB Piezotronics Inc. claims proprietary rights in REVISIONS the information disclosed hereon. Neither it nor any reproduction thereof will be disclosed to others DESCRIPTION without the written consent of PCB Piezotronics Inc. STANDARD STUD MOUNT UPDATE DRAWING 25686 "A" "B"...
Need help?
Do you have a question about the 3713B112G and is the answer not in the manual?
Questions and answers