Weil-McLain Eco Tec 80-H User's Information Manual page 11

Wall mount gas - fired condensing boilers - combi and heating only
Hide thumbs Also See for Eco Tec 80-H:
Table of Contents

Advertisement

ECO
®
Tec
series 2 gas-fired water boiler – user's information manual
The ECO Tec control display
Figure 8
ECO Tec boiler control display USER Menu — (set date and time, reset faults).
MENU
DATE/TIME
BACKLIGHT
CLEAN
NETWORK
HOT WATER
MAINTENANCE
2/28/20
9:45AM
WIRELESS STATUS
BLUETOOTH
ON
FCC: 2AC7Z-ESP32WROOM32E
IC: 21098-ESPWROOM32E
2/28/20
9:45AM
Figure 9
ECO Tec boiler control display LOCKOUT SCREEN — screen turns red when boiler locks out —
highlight and select MANUAL RESET to reset boiler as shown below.
ECO TEC 110C
84
LOW WATER CUTOFF
°F
5/29/20
11:30AM
Figure 10
ECO Tec boiler control display Maintenance notice screens.
MAINTENANCE
NAME:
ECO TEC 110 COMBI
PHONE:
MODEL:
ECO TEC 110 COMBI
CP:
INSTALLED:
LAST DATE:
INTERVAL SET:
LAST CALIBRATION:
5/29/20
11:30AM
The left maintenance screen can be accessed from the User Menu screen. Maintenance intervals should be set by a qualified technician
when the boiler is initially installed.
When maintenance is due, the main screen will display wrenches like in the right picture. When maintenance is due, please have a
qualified technician inspect the boiler. When maintenance reminder screen is displayed, you will be able to reset it to clear the reminder.
Part number 550-100-271/1021
Date/Time:
Backlight:
Clean:
SOFTWARE
BLUETOOTH
Software:
SETTINGS
Bluetooth
BLUETOOTH STATUS
Assembled From
tested components
Complete system
not tested
Hot Water:
Maintenance:
Settings:
Resetting fault :
1. During a fault the status will change to LOCKOUT and the screen will look
2. The user will have to select reset on the screen.
3. Once selected the user will have to press the Reset button on the following
RESET
4.
1234567890
EDIT
1234567890
1/01/20
1/01/20
12 MONTHS
1/01/20 12:00 PM
(continued)
Allows user to edit the current date, time, and daylight savings time.
Allows user to edit how bright the screen is during normal
operation and when dormant.
Locks the screen so nothing can be pressed for 10 seconds while
the user cleans the screen.
Displays the current software revisions of the control and display.
:
Allows the user to turn Bluetooth ON or OFF. Swipe right from
®
HOME and press BLUETOOTH to reach FCC and IC information.
FCC:
Wireless device unique identifier registered with the U.S. Federal
Communications Commission.
IC:
Wireless certification approval number unique to all devices,
required for Canada.
• This device complies with Part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) this device may
not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause
undesired operation.
FOR COMBI MODELS ONLY
Allows the user to edit the Hot Water Temp of the Combi demand,
as well as enable or disable Keep Hot mode or ECO BOOST mode.
Allows the user to view contractor and maintenance information,
as well as reset the maintenance reminder when present.
Allows the user to edit temperature units, screen time out, and
sound effect of presses.
like the display to the left. Low Water Cutoff is used for this example.
screen to reset the fault.
Call for service if fault continues.
ECO TEC 110C
5/19/20
8:30AM
Screens shown are typical only. Actual
screens depend on control settings chosen.
84
°F
11