6. Electrical work
ON/OFF
MODE
CHECK
TEST RUN
SET
1,4
Fig. 6-9
Service menu
Test run
Input maintenance info.
Settings
Check
Others
Main menu: RETURN
Cursor
Fig. 6-10
Function setting
Ref. address
Unit No.
Grp./1/2/3/4/All
Monitor: SELECT
Cursor
Address
F1
F2
F3
F4
ON
RETURN SELECT
MENU
OFF
HOLD
Fig. 6-12
Function setting
Grp.
Ref. address
Mode 1
Mode 2
Mode 3
Mode 4
Request: SELECT
Cursor
Cursor
F1
F2
F3
F4
ON
RETURN SELECT
MENU
OFF
HOLD
Fig. 6-14
A
TEMP
3
FAN
AUTO STOP
VANE
AUTO START
LOUVER
h
min
2
RESET
CLOCK
Settings menu
Function setting
Service menu: MENU
F1
F2
F3
F4
ON
RETURN SELECT
MENU
OFF
HOLD
Fig. 6-11
Function setting
Grp.
Ref. address
Mode 1
Mode 2
Mode 3
Mode 4
Cursor
Cursor
F1
F2
F3
F4
ON
RETURN SELECT
MENU
OFF
HOLD
Fig. 6-13
Function setting
Ref. address
Grp.
Sending data
F1
F2
F3
F4
ON
RETURN SELECT
MENU
OFF
HOLD
Fig. 6-15
2) Assigning a IR wireless remote controller to each unit
Each unit can be operated only by the assigned IR wireless remote controller.
Make sure each pair of an indoor unit PC board and a IR wireless remote controller
is assigned to the same pair No.
3) IR wireless remote controller pair number setting operation (Fig. 6-9)
1 Press the SET button with something sharp at the end.
Start this operation from the status of IR wireless remote controller display
turned off.
blinks and Model No. is lighted.
min
2 Press the
button twice continuously.
Pair No. "0" blinks.
3 Press the temp
button to set the pair number you want to set.
4 Press the SET button with something sharp at the end.
Set pair number is lighted for three seconds then turned off.
A Pair No. of IR wireless remote controller
0
1
2
3-9
6.3. Function settings
6.3.1. Function setting on the unit (Selecting the unit functions)
1) For wired remote controller
1 (Fig. 6-10)
• Select "Service" from the Main menu, and press the [SELECT/HOLD] button.
• Select "Settings" from the Service menu, and press the [SELECT/HOLD]
button.
2 (Fig. 6-11)
• Select "Function settings" with the [SELECT/HOLD] button.
3 (Fig. 6-12)
• Set the indoor unit refrigerant addresses and unit numbers with the [F1]
through [F4] buttons, and then press the [SELECT/HOLD] button to confirm
the current setting.
<Checking the Indoor unit No.>
When the [SELECT/HOLD] button is pressed, the target indoor unit will start fan
operation. If the unit is common or when running all units, all indoor units for the
selected refrigerant address will start fan operation.
4 (Fig. 6-13)
• When data collection from the indoor units is completed, the current settings
appears highlighted. Non-highlighted items indicate that no function settings
are made. Screen appearance varies depending on the "Unit No." setting.
5 (Fig. 6-14)
• Use the [F1] or [F2] button to move the cursor to select the mode number, and
change the setting number with the [F3] or [F4] button.
6 (Fig. 6-15)
• When the settings are completed, press the [SELECT/HOLD] button to send
the setting data from the remote controller to the indoor units.
• When the transmission is successfully completed, the screen will return to the
Function setting screen.
Indoor PC board
Factory setting
Cut J41
Cut J42
Cut J41, J42