Supported command classes ................. p. 22 EU declaration of conformity CHERUBINI S.p.A. declares that the product is in conformity with the relevant Union harmonisation legislation: Directive 2014/53/EU, Directive 2011/65/EU. The full text of the EU declaration of conformity is available upon request at the following website: www.cherubini.it.
DEVICE DESCRIPTION META Smart Plug is able to detect overvoltage and/or overcurrent events and indicate them through a multicolor LED. Furthermore, it protects appliances from eventual overload. A very innovative design, which integrates a complex system that allows a precise energy consumption monitoring. The integration of these features in its very small size product, make it unique on the market.
TECHNICAL SPECIFICATIONS Power Supply 230 VAC ± 10% 50/60 Hz Maximum Load on Relay 2800 VA – 230 VAC – 12A Temperature limitation 105 °C Work Temperature From -10° to 40° C Power consumption < 0.4 Watt Radio frequency 868.4 MHz Protection system S0 and S2 Security Maximum distance...
LED STATUS INDICATOR The system includes an RGB LED that shows the device’s status during the installation procedure: One single BLUE blink: when connecting to the power supply and the device is not yet included in the Z-Wave network OFF: the relay is OFF Solid GREEN: the relay is ON Blink GREEN - BLUE: Learn mode for Inclusion and Exclusion Blink GREEN: the device is indicating Overcurrent event...
CONTROLLING THE DEVICE Controlling the load through the Smart Plug A single click or two clicks on the Push Button can turn ON/OFF the load (Parameter No. 1). Controlling the device through Z-Wave network META Smart Plug can be controlled by any Z-Wave / Z-Wave Plus certified controller available in the market.
ASSOCIATIONS META Smart Plug can control, through direct association, other devices of the Z-Wave network in which is included, when an event of overcurrent, overvoltage or events on the Push Button occur. META Smart Plug can control devices such as relays or dimmers. META Smart Plug supports 5 association groups, each of which supports the association of up to 8 devices: 1-Lifeline: Nodes belonging to this groups will receive changes related to the relay status and power consumption;...
CONFIGURATIONS Parameter No. 1: Local load control (1 Byte) Defines which sequences of clicks control the local load. Configuration Result ONE_CLICK 1 click turn ON/OFF the local load TWO_CLICKS 2 clicks turn ON/OFF the local load ONE_CLICK or TWO_CLICKS (Default Value) 1 click or 2 clicks turn ON/OFF the local load Controlling the associated devices Parameter No.
Page 10
Overvoltage Alarm Parameter No. 4: Overvoltage level (2 Byte). Defines the voltage level (in Volts) beyond which an overvoltage event is identified and the overvoltage timer is activated. The timer is reset when the event ceases, i.e. when the voltage returns below the overvoltage level. As soon as an overvoltage event occurs, the LED starts a BLUE blinking.
Page 11
Overcurrent Alarm Parameter No. 8: Overcurrent level (1 Byte). Defines the current level (in Amps) beyond which an overcurrent event is identified and the overcurrent timer is activated. The timer is reset when the event ceases, i.e. when the current returns below the overcurrent level. As soon as an overcurrent event occurs, the LED starts a GREEN blinking.
Parameter No. 11: Level used to control the devices associated to group 2 (1 Byte). Defines how to control the devices associated to the overcurrent alarm. Configuration Result SWITCH_OFF (Default Value) The associated devices are switched OFF SWITCH_ON The associated devices are switched ON LEVEL 1 - 99 The associated devices are set to the indicated level...
Page 14
CHERUBINI S.p.A. Via Adige 55 25081 Bedizzole (BS) - Italy Tel. +39 030 6872.039 | Fax +39 030 6872.040 info@cherubini.it | www.cherubini.it CHERUBINI Iberia S.L. Avda. Unión Europea 11-H Apdo. 283 - P. I. El Castillo 03630 Sax Alicante - Spain Tel.