50GCQJ05 Three Phase — 4 Ton Vertical Supply (rpm - bhp)
CFM
0.2
rpm
bhp
1200
1047
0.12
1300
1102
0.14
1400
1158
0.17
1500
1217
0.19
1600
1278
0.22
1700
1341
0.25
1800
1404
0.29
1900
1470
0.33
2000
1536
0.38
CFM
1.2
rpm
bhp
1200
1869
0.70
1300
1897
0.73
1400
1926
0.76
1500
1957
0.80
1600
1990
0.84
1700
2024
0.88
1800
2060
0.92
1900
2098
0.97
2000
2137
1.02
Standard Static 1047-1900 rpm, 0.72 Max bhp
Medium Static 1047-2170 rpm, 1.06 Max bhp
High Static 1047-2660 rpm, 1.96 Max bhp
50GCQJ05 Three Phase — Standard Static — 4 Ton Vertical Supply (rpm - vdc)
CFM
0.2
rpm
vdc
1200
1047
5.5
1300
1101
5.8
1400
1158
6.1
1500
1217
6.4
1600
1277
6.7
1700
1340
7.1
1800
1404
7.4
1900
1469
7.7
2000
1535
8.1
CFM
1.2
rpm
vdc
1200
1869
9.8
1300
1897
10.0
1400
1500
1600
1700
1800
1900
2000
Standard Static 1047-1900 rpm
APPENDIX C — FAN PERFORMANCE (cont)
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
0.4
rpm
bhp
rpm
1252
0.21
1431
1293
0.23
1467
1337
0.26
1505
1383
0.28
1545
1432
0.31
1587
1483
0.34
1631
1536
0.38
1676
1592
0.42
1724
1649
0.47
1774
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
1.4
rpm
bhp
rpm
1994
0.86
2111
2020
0.89
2136
2047
0.92
2162
2077
0.95
2190
2107
0.99
2219
2140
1.04
2250
2174
1.08
2282
2209
1.13
2315
2246
1.19
2351
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
0.4
rpm
vdc
rpm
1251
6.6
1431
1293
6.8
1467
1337
7.0
1505
1383
7.3
1545
1432
7.5
1587
1483
7.8
1631
1536
8.1
1677
1592
8.4
1724
1649
8.7
1774
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
1.4
rpm
vdc
rpm
0.6
bhp
rpm
0.32
1590
0.34
1622
0.36
1657
0.39
1693
0.42
1732
0.46
1771
0.50
1813
0.54
1855
0.58
1900
1.6
bhp
rpm
1.02
2221
1.05
2246
1.08
2271
1.12
2297
1.16
2325
1.20
2354
1.25
2385
1.30
2417
1.36
2451
0.6
vdc
rpm
7.5
1590
7.7
1622
7.9
1657
8.1
1693
8.4
1731
8.6
1771
8.8
1812
9.1
1855
9.3
1900
1.6
vdc
rpm
66
0.8
1.0
bhp
rpm
0.43
1735
0.46
1765
0.49
1796
0.52
1830
0.55
1865
0.59
1902
0.63
1940
0.67
1980
0.72
2021
1.8
2.0
bhp
rpm
1.18
2324
1.22
2350
1.25
2375
1.29
2400
1.33
2427
1.38
2455
1.43
2484
1.48
2515
1.54
2547
0.8
1.0
vdc
rpm
8.4
1735
8.5
1765
8.7
1796
8.9
1830
9.1
1865
9.3
9.5
9.8
10.0
1.8
2.0
vdc
rpm
bhp
0.56
0.59
0.62
0.65
0.69
0.73
0.77
0.81
0.86
bhp
1.35
1.39
1.43
1.47
1.52
1.56
1.61
1.67
1.73
vdc
9.1
9.3
9.5
9.6
9.8
vdc

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

50gcqj0450gcqj0550gcqj0650gcqt0450gcqt0550gcqt06

Table of Contents