Mitsubishi Electric SUZ-KA18NA2 Service Manual page 19

Hide thumbs Also See for SUZ-KA18NA2:
Table of Contents

Advertisement

10-3-3. Self-diagnosis <Wireless remote controller>
<In case of trouble during operation>
When a malfunction occurs to air conditioner, both indoor unit and outdoor unit will stop and operation lamp blinks to inform
unusual stop.
<
Malfunction-diagnosis method at maintenance service>
CHECK
CHECK
display
TEMP
ON/OFF
ON/OFF
button
AUTO STOP
FAN
MODE
AUTO START
VANE
CHECK LOUVER
CHECK
min
TEST RUN
button
RESET
SET
CLOCK
OCH688D
[Procedure]
1. Press the CHECK button twice.
Refrigerant
• "CHECK" lights, and refrigerant address "00" blinks.
address
• Check that the remote controller's display has stopped before continuing.
display
2. Press the temperature
• Select the refrigerant address of the indoor unit for the self-diagnosis.
Temperature
Note: Set refrigerant address using the outdoor unit's DIP switch (SW1).
button
(For more information, see the outdoor unit installation manual.)
3. Point the remote controller at the sensor on the indoor unit and press the
HOUR button.
• If an air conditioner error occurs, the indoor unit's sensor emits an intermittent
buzzer sound, the operation light blinks, and the check code is output.
HOUR
(It takes 3 seconds at most for check code to appear.)
button
h
4. Point the remote controller at the sensor on the indoor unit and press the ON/
OFF button.
• The check mode is cancelled.
buttons.
19