SCA14000 Cobalt Operation Manual TABLE OF CONTENTS DISCLAIMER ---------------------------------------------------------------------- 2 SAFETY PRECAUTIONS --------------------------------------------------- 3-8 HOW IT WORKS ----------------------------------------------------------------- 9 FEATURES AND SPECIFICATIONS -------------------------------------- 10 PART NAMES ------------------------------------------------------------------- 11 INSTALLATION REMARKS --------------------------------------------- 12-14 UNIT OPERATION --------------------------------------------------------- 15-18 REMOTE CONTROL ---------------------------------------------- 18...
SCA14000 Cobalt Operation Manual DISCLAIMER A printed copy of all the electronic materials is included in the unit packaging. Read the label on the unit and operating manual before use and make sure to follow all the precautions outlined in the manual.
SCA14000 Cobalt Operation Manual SAFETY PRECAUTIONS FIRST AID INSTRUCTIONS In case of injury, clean the area using soap and warm water, apply antibiotic ointment and a bandage, and seek immediate medical attention. FCC Warning Statements This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
Page 5
SCA14000 Cobalt Operation Manual SAFETY PRECAUTIONS ISED Warning Statements This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s license-exempt RSS(s). Operation is subject to the following two conditions: (1) This device may not cause interference; and (2) This device must accept any interference, including interference that may cause undesired operation of the device.
Page 6
SCA14000 Cobalt Operation Manual SAFETY PRECAUTIONS OPERATING ENVIRONMENT CAUTIONS • DO NOT place in rooms with high heat, damp, or wet places. DO NOT use outdoors. • DO NOT use extension cord with this fan. • • Not for use in kitchens.
Page 7
If construction needs to be conducted in an area where Cobalt units are installed, it is recommended that the unit is turned off.
Page 8
– TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, AND INJURY TO PERSONS, Cobalt unit must be installed with brackets and screws that are marked in the installation manual to indicate the suitability with this model. Other types of brackets and fasteners cannot be substituted.
Page 9
SCA14000 Cobalt Operation Manual SAFETY PRECAUTIONS CARE AND MAINTENANCE/ SERVICING CAUTIONS WARNING – RISK OF FIRE. Never operate the air purifier in a space that contains flammable gases. Never use the equipment to extract or filter flammable, blazing or burning particles, chemicals, or liquids. Never use the unit to extract or filter hostile vapors or sharp particles.
SCA14000 Cobalt Operation Manual HOW IT WORKS When the fan motors are running, the indoor air will be drawn through the front of the unit. The air will then pass through the Filters. The purified air is then released through the outlet on both ends of the unit.
SCA14000 Cobalt Operation Manual FEATURES AND SPECIFICATIONS This device features: Automatic Proximity Sensor On/Off Automatic Timer Remote Control Model No. SCA14000–2x4 Power Requirement 120 VAC, 60 Hz Rated Power 250 W, 2.1 A Fan Motor 310 VDC, 0.98 A, 113 W Dimensions (L) 1245.0 mm x (W) 636.0 mm x (H) 360.0 mm...
SCA14000 Cobalt Operation Manual PART NAMES Front Access Panel & Inlet Vent Main Body "Surgically Clean Air™” Logo and LED Motor and Fan User Interface/ Display and Electrical Power Box Touch Panel PCB Board 10. Mount Bracket and Screws Pre-Filter + HEPA Filter 11.
SCA14000 Cobalt Operation Manual INSTALLATION REMARKS The SCA14000 is designed to be installed as a fixed built-in unit by a qualified installer. In addition to the following instructions the SCA14000 shall be installed: In the United States, in accordance with the National Electric Code/State, ANSI/NFPA 70 and Municipal codes •...
Page 14
SCA14000 Cobalt Operation Manual INSTALLATION REMARKS • The Cobalt unit can be hoisted from the concrete ceiling or the I-beam. Please refer to the Installation Guide for detailed instructions. • Ensure the unit is being installed level in both directions.
Page 15
• For new installation, the work must be performed by a qualified installer. It is recommended that Cobalt unit is positioned centrally within a room. It is important that the intake side of • the unit is away from the supply of the HVAC system. To improve air quality in the room, the unit should circulate and filter the existing air in the room, not the fresh air supplied by the HVAC system.
SCA14000 Cobalt Operation Manual UNIT OPERATION The power button light and “Surgically Clean Air™” LED will turn on when power button is pressed. Use the button to adjust the fan speed. When the unit is first turned on the fan speed is by default on Turbo. The display indicator will show the unit speed.
Page 17
SCA14000 Cobalt Operation Manual UNIT OPERATION Pressing the will turn the control panel and “Surgically Clean Air™” LED on/off. Pressing the will activate the timer, the unit will shut off after set time is passed, set time is shown on the control panel.
Page 18
SCA14000 Cobalt Operation Manual UNIT OPERATION ICON ACTION RESPONSE Press ON/OFF Press and hold for 10 seconds Reset Filter Timer After Replacement Surgically Clean Air™” Turn Control Panel and “ Press ON/OFF. Press Proximity Sensor is ON Press and hold for 5 seconds...
SCA14000 Cobalt Operation Manual UNIT OPERATION REMOTE CONTROL The unit is supplied with a Remote Control that operates similar to the unit’s control panel. ICON ACTION RESPONSE Press ON/OFF 2 | 6 | 12 | 24 Press Activate Timer for 2, 6, 12, 24 hours “Surgically Clean Air™”...
SCA14000 Cobalt Operation Manual CARE AND MAINTENANCE To maintain optimum performance of this air purifier, the filters need to be replaced when “Surgically Clean Air™” LED flashes (Breathing Flash). If the device is operating in an atmosphere with heavy dust, particulate, or pet dander, you may need to periodically vacuum the pre-filters for optimal performance.
SCA14000 Cobalt Operation Manual CARE AND MAINTENANCE REPLACING THE FILTERS 1.When the “Surgically Clean Air™” LED starts flashing (Breathing Flash), the filters need to be replaced.
Page 22
SCA14000 Cobalt Operation Manual 2.Turn the unit off and disconnect the plug from the outlet. 3.Open the front panel by sliding the latches open on both sides.
Page 23
SCA14000 Cobalt Operation Manual 4a. 2×4 Model: Use tabs on the filter to slide both filters out of the housing and remove the filters from the unit. 4b. 2×2 Model: Rotate the lock tab 90 degrees and remove the filters from the unit.
Page 24
SCA14000 Cobalt Operation Manual 5.Clean the interior compartment of the unit by vacuuming and removing any debris that has accumulated.
Page 25
SCA14000 Cobalt Operation Manual 5a. 2×4 Model: Place new filters in the housing and make note of the air-flow direction. Slide the filter in place; the pre-filter mesh should point outwards. The filters should be pressed against the grill panel.
Page 26
SCA14000 Cobalt Operation Manual 7.It is recommended to clean the air inlet with a vacuum cleaner after the filters are replaced.
SCA14000 Cobalt Operation Manual CARE AND MAINTENANCE CLEANING THE UNIT 1.Turn the unit off and disconnect the plug from the outlet. 2.It is recommended to vacuum the pre- filters and air inlets every 6 months for optimal performance.
Page 28
SCA14000 Cobalt Operation Manual NOTE: Pre-filter mesh should be facing outwards as shown.
Page 29
SCA14000 Cobalt Operation Manual 3.Wipe the exterior of the unit with a soft, clean and lint free cloth. - DO NOT use volatile fluids, gasoline, chemical solvents, benzene, paint thinner or corrosive/ abrasive materials and polishing powder as this may damage the surface.
SCA14000 Cobalt Operation Manual TROUBLESHOOTING Most service problems that appear to be major can often be resolved easily. You can be your own troubleshooter by reviewing the following guide. All other major servicing should be done by the manufacturer. SOLUTION...
Page 31
SCA14000 Cobalt Operation Manual One or both HEPA filters are Replace HEPA filter(s) fully loaded Replace HEPA filters and reset “Surgically Clean Air™” LED Filter change cycle timer expired the timer flashing Replace batteries Battery nearly exhausted Remote Control is...