Integrated control system

Advertisement

No.
Name
11
Relay OUTPUT
IR-SERIAL
12
OUTPUT
Table 5-1: Pin-outs of the 9-pin phoenix connector for COM1/2/3/4
Note: In RS485 mode, the wires connecting to PIN1 and PIN3 should be stranded
as one, PIN2 and PIN4 as another one.
The Controller features 8 sets of relay 2-PIN phoenix
connectors; each relay is isolated and normally open,
and can switch up to 2A 30VDC / 1A 125VAC peak.
The connector does not support voltage output.
The Controller features 8 sets of multi-mode 2-PIN
phoenix connectors for IR transmitting or one-way
serial signal outputting. The ports can connect to devices
with signal level 0-5V in RS232 mode. The left pin is for
IR/serial data, the right for GND.
The IR-Serial working mode is programmable:
In IR transmitting mode, the outputting IR wave length
ranges within 20K-60KHZ.
In one-way serial data outputting mode, the left pin is
for TXD, the right for GND, and both are configurable in
the program.
PIN1
RX- (used in RS422 and RS485)
PIN2
RX+ (used in RS422 and RS485)
PIN3
TX- (used in RS422 and RS485)
TX+ (used in RS422 and RS485)
PIN4
PIN5
GND
PIN6
TXD (used in RS232 and RS232+hardware flow)
PIN7
RXD (used in RS232 and RS232+hardware flow)
PIN8
RTS (used in RS232+hardware flow)
PIN9
CTS (used in RS232+hardware flow)