PROGRAMMABLE
THERMOSTAT
®
Owners Manual
Congratulations!
Your new Climate Technology thermostat will provide years of reliable service. By saving
energy, your thermostat will pay for itself during its first season of use. Thank you for
buying a Hunter product!
Please read this manual for complete instructions on installing and operating your
thermostat. If you require further assistance, call Climate Technology Technical
Support at 1-800-676-7861 from 8am to 5pm Central Time.
Ask Your Local Retailer for Other Quality Products from CTC
Thermostat Guards
Air Purifiers
IMPORTANT INFORMATION
1. This thermostat is designed to work on the following systems:
Gas - Standing Pilot
Electric Furnace
Gas - Electronic Ignition
Electric Air Conditioning
Gas - Fired Boilers
Gas - Milivolt Systems
Oil - Fired Boilers
This thermostat will NOT control single-stage or multi-stage
Oil - Fired Furnace
heat pumps or 110/220 V baseboard electric heating
systems.
2. Temperature Range
This thermostat can be programmed between 45°F and 95°F (7°C and 35°C).
However, it will display room temperatures from 30°F to 99°F (0°C and 37°C). "HI"
will be displayed if the temperature is higher than 99°F (37°C), and "LO" will be
displayed if the temperature is lower than 30°F (0°C).
This thermostat will automatically cut-off in Heat mode if the temperature rises above
95°F (35°C), and automatically cut-off in Cool mode if the temperature drops below
45°F (7°C).
3. Compressor Protection
This thermostat provides a 3.5 minute delay after shutting off the cooling system
before it can be restarted. This feature will prevent damage to your compressor
caused by rapid cycling. It does not prevent a rapid compressor restart due to short
power outages.
4. Battery Warning
Two fresh AA alkaline batteries should provide well over one year of service.
However, when the batteries become drained, the Low Battery Indicator will flash on
the display. When this message occurs, install new alkaline batteries. You have
approximately 1 minute to change the batteries and keep thermostat's clock and
program settings. Once the batteries have become too low to ensure proper
operation, your system will be turned Off, and the display will be cleared except for
flashing Low Battery Indicator on the LCD display.
CAUTION: When ONLY the battery icon flashes on the display, the
!
thermostat is shut down, and your system will no longer operate. In
this condition, there is no temperature control of your dwelling.
®
NOTE: The INDIGLO
night-light will not function when the thermostat is in low
battery condition.
NOTE: If you plan to be away from the premises over 30 days, we recommend
that you replace the old batteries with new alkaline batteries prior to leaving.
FEATURES
LCD Display: Shows Time, Day, Temperature, Program Number,
and other feature information as required.
Low Battery Indicator:
Flashes when batteries need
to be replaced.
TH
PM
®
INDIGLO
night-light:
3
HEAT
TEMP
Backlights display
automatically with each key
press for easy viewing.
System Switch: Selector
DAY/TIME
PROGRAM
switch for Heat, Cool, and Off.
HEAT OFF COOL
HOLD/RET
RESET
Fan Switch: Fan switch for
FAN ON AUTO
Automatic or Continuous fan
operation.
Battery Compartment:
Front access allows easy
insertion of two AA 1.5V
batteries.
Reset: Press with a paper
clip to reset the thermostat
and return to power-up
Front Door: Covers keys when not used for neat
settings.
appearance. Open with one finger from either side.
INSTALLATION
What You Need
This thermostat includes two #8 slotted screws and two wall anchors for mounting.
To install your thermostat, you should have the following tools and materials.
Slotted Screwdriver(s)
Small Philips screwdriver
Hammer
Electric drill and 3/16" bit
Two 1.5 V (AA) size alkaline batteries
Remove Old Thermostat
CAUTION: Do not remove any wiring from existing thermostat before reading
the instructions carefully. Wires must be labeled prior to removal.
IMPORTANT! Turn off the power to the furnace at the main power panel or at the
furnace.
Remove existing thermostat cover and thermostat. See Figure 1. Some
thermostats will have screws or other locking devices that must first be removed.
Once the wall mounting plate is exposed, look for wires.
If wires are not visible, they may be connected to the back of the wallplate. Again,
look for screws, tabs, etc. Some models have doors that open to expose wires and
mounting screws. See Figure 1.
Typical Home Thermostats
All manuals and user guides at all-guides.com
Wall Mounting Plate
Wall Mounting Plate
Wire Labeling
Each wire coming from the wall to the existing thermostat is connected to a
Model 43153
terminal point on that thermostat. Each of these terminal points is usually marked
with a code letter as shown in Table A below.
The number of wires in your system can be as few as two (for heat only systems),
as many as eight, or any number in between. If you follow the labeling procedures
correctly, you do not have to be concerned about how many wires there are.
There is often no terminal marking on the existing thermostat of two wire, heat only
systems. Just connect either of the wires to the RH terminal, then connect the
other wire to the W terminal to complete the circuit.
IMPORTANT! BEFORE DISCONNECTING ANY WIRES, APPLY THE SELF-
ADHESIVE LABELS PROVIDED TO THE WIRE AS SHOWN IN
TABLE A BELOW. (For example, attach the label marked W to
the wire that goes to the W or H terminal on your existing
thermostat.) IGNORE THE COLOR OF THE WIRES since
these do not always comply with the standard.
After labeling wires, disconnect them from the existing
thermostat terminals.
Remove existing wallplate. To make sure wires do not fall back into wall opening,
you may want to tape them to the wall.
If hole in wall is larger than necessary for wires, seal this hole with insulating
material so that no hot or cold air can enter the back of the thermostat from the
wall. This air could cause a false thermostat reading.
Humidifiers
If the code letter on your
existing thermostat is
RH, R, VR or 4
24 Volt
RC, VC
24 Volt Cool
G or F
Fan
Y, C or M
Air Conditioning
Compressor
W or H
Heating
NOTE: Do not connect a "Common" wire (sometimes labeled "C") to any
terminal on this thermostat. Tape up the wire and do not use. This wire provides
electricity to non-battery powered thermostats.
Mount Wallplate and Thermostat
Remove the wallplate from your thermostat by pressing the release tab on the
bottom of the thermostat. See Figure 2.
Up and Down Keys: Keys for
changing the Temperature
setting. Also used for increasing
and decreasing selections in the
Time, Program, and Span
functions.
Day/Time Key: Used for entering
the Clock setting mode. Use
Position wallplate on wall and pull existing wires through large opening. Then level
with the Up and Down keys to
set the time and day.
for appearance. Mark holes for plastic anchors provided, if your existing holes do
not line up with those on the Hunter wallplate.
Program Key: Used for entering
Drill holes with 3/16" bit and gently tap anchors into the holes until flush with wall.
and modifying Programs. Use
Reposition wallplate to wall, pulling wires through large opening. Insert mounting
with the Up and Down keys to
screws provided into wall anchor and tighten. See Figure 3.
set times and temperatures.
Press when in Clock setting
mode to select between 12 and
24 hour clock modes.
Hold / Return Key: Used for
setting a permanent (vacation)
hold, and for returning to the
normal display from Day & Time
setting, Programming, or Span
setting modes.
NOTE: 5-wire Systems
If your thermostat has one wire marked R or RH (2, 3, or 4-wire system), then leave
the jumper wire between the RH and RC terminals on the wallplate. Otherwise, if you
have separate RH and RC wires (5-wire system), then remove the jumper wire
between the RH and RC terminals.
Connect Wires and Mount Thermostat to Wallplate
Match and connect the labeled wires to the appropriate coded terminal screws on
the wallplate. (See Figure 4, 5.) Ignore any wires which may be present, but which
were not connected to the old thermostat.
Refer to the Wiring Diagrams below to be sure your system is wired correctly.
Be sure to tighten the terminal screws securely, otherwise a loose wire could cause
operational problems with your system or thermostat.
Thermostat
Cover
Push excess wire back into the hole to prevent interference when installing the
thermostat to the wallplate.
Make sure the System Switch is set to OFF, and the Fan Switch is set to AUTO.
Insert the bottom tab on the thermostat body into the slot at the bottom of the
wallplate. Press the top of the thermostat body to snap it into the wallplate. Refer to
Figure 6. (NOTE: Do not force the thermostat onto the wallplate, as the
terminal pins may be damaged. If it does not snap properly, the thermostat
Thermotat
Cover
may not work.)
Insert the two AA size alkaline batteries, observing the polarity marked inside the
Figure 1
battery compartment.
Switch on the main power at the panel or furnace.
G Y
W
RH
RC
then mark the wire
and connect to thermostat
with label shown
terminal shown
RH
x
RC
x
G
x
Y
x
Wiring Diagrams
W
x
Table A
Figure 2
X – No Connection
Figure 3
RH
x
+
x
+ x
x
G
RC
Y
W RH
Figure 5
Figure 4
Figure 6
4-wire Heat/Cool System
Wallplate
Jumper
Terminals
Rh
G
Rc
Y1
Y/O
W/B
X
X
Fan
Cool
Heat Relay
Heat/Cool
Relay
Contactor
or Valve
24V Supply
5-wire Heat/Cool System
Wallplate
No Jumper
Terminals
G
Rc
Y1
Rh
Y/O
W/B
X
Fan
Cool 24V
Cool
Heat Relay
Heat 24V
Relay
Supply
Contactor
or Valve
Supply
2-wire Heat Only System
Wallplate
Jumper
Terminals
G
Rc
Y
W
Rh
X
X
X
Heat Relay
Heat 24V or
or Valve
Millivolt Supply
3-wire Heat Only System
Wallplate
Jumper
Terminals
G
Rc
Y
W
Rh
X
X
Fan
Heat Relay
Heat 24V
Relay
Supply
or Valve
3-wire Cool Only System
Wallplate
Jumper
Terminals
Rh
G
Rc
Y
W
X
X
Fan
Cool 24V
Cool
Relay
Supply
Contactor

Advertisement

loading

Summary of Contents for CTC Union 43153

  • Page 1 Each wire coming from the wall to the existing thermostat is connected to a Owners Manual Model 43153 terminal point on that thermostat. Each of these terminal points is usually marked with a code letter as shown in Table A below.
  • Page 2 Cooling All manuals and user guides at all-guides.com Selector Switches SPAN Setting Mode In order for this thermostat to control your system, the system type must be specified Your thermostat is set at the factory to cycle at 1°F (0.5°C) above and below the set Program 1 Program 2 Program 3...