INSTRUCTIONS FOR CONNECTION
THE BATTERY PACK TO DEYE INVERTERS
LITHIUM IRON PHOSPHATE
LIFEPO4 BATTERY PACK
51,2V 100Ah
KT-LFPES512100
1. PRECONDITIONS
Before connecting the battery with inverter.make sure the following rules are complied.
1.
The battery system discharge power/current is proper with the inverter power. It is recommended to configure the inverter
capacity with battery in 1: 2 proportion, for example. If you have a 5 kW rated inverter, connect at least 2 batteries (10kWh),
2.
If the system is an off-grid system, make sure that configuration can manage to avoid overdischarging the battery. It is strongly
recommended to install a smart generator and MPPT modules (brands like Victron that support DC-coupled application).
3.
Make sure that the installation environment, setting and sequence is following the User Manual.
2. COMMISSIONING WITH INVERTER
2.1 DEVICE SUPPORT
Deye/Sunsynk Hybrid inverter and Kon-TEC KT-LFPES512100 battery can be used for following system types
- Energy Storage Systems
- Grid Backup
- Off-grid
Compatible device:
SUN-SG04LP1-EU / SUN-SG03LP1-EU / SUN-SG05LP1-EU / SUN-SG04LP3-EU / SUN-SG01LP1-EU
2.1.1 CABLE CONNECTION
1. Keep both inverter and battery completely off.
2. Connect the communication cable to the system according to the following schematic
Kon-TEC Battery BMS CAN port
Pin 4
H
Pin 5
L
Pin 6
GND
1/3
Deye/Sunsynk inverter CAN
port
Pin 4
H
Pin 5
L
Pin 2 or Pin
GND
6 (based on
model)
https://www.kon-tec.eu/
Kon-TEC sp. z o.o.
Boya-Żeleńskiego 12, 35-105 Rzeszów, Poland
T: +48 572 001 151 E: info@kon-tec.eu W: www.kon-tec.eu