troubleshooting
problem
Tool will not start.
1. Cord not connected.
2. No power at outlet.
3. Tool's thermal reset breaker
4. Internal damage or wear.
Tool operates slowly. 1. Forcing tool to work too fast.
2. Extension cord too long or cord
Performance
1. Carbon brushes worn
decreases over time.
2. Bit dull or damaged.
Excessive noise
Internal damage or wear. (Carbon
or rattling.
brushes or bearings, for example.)
Overheating.
1. Forcing tool to work too fast.
2. Bit dull or damaged.
3. Blocked motor housing vents.
4. Motor being strained by long or
Follow all safety precautions whenever diagnosing or servicing the tool.
Disconnect power supply before service.
pLeaSe reaD tHe FOLLOWinG careFuLLy
THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM
IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR DISTRIBUTOR
MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS
QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS QUALIFIED TO REPLACE
ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY
STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND
LICENSED TECHNICIANS, AND NOT BY THE BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY
ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS
THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO.
record product's Serial number Here:
note: if product has no serial number, record month and year of purchase instead.
note: Some parts are listed and shown for illustration purposes only, and are not available
individually as replacement parts. Specify UPC 193175434296 when ordering parts.
Item 58214
possible causes
tripped (if equipped).
(Carbon brushes or
Trigger, for example.)
diameter too small.
or damaged.
small diameter extension cord.
For technical questions, please call 1-888-866-5797.
Likely Solutions
1. Check that cord is plugged in.
2. Check power at outlet. If outlet is unpowered,
turn off tool and check circuit breaker.
If breaker is tripped, make sure circuit is right
capacity for tool and circuit has no other loads.
3. Turn off tool and allow to cool.
Press reset button on tool.
4. Have technician service tool.
1. Allow tool to work at its own rate.
2. Eliminate use of extension cord. If an extension
cord is needed, use one with the proper diameter
for its length and load. See Extension Cords
in Grounding section on page 5.
1. Have qualified technician replace brushes.
2. Keep bits sharp. Replace as needed.
Have technician service tool.
1. Allow tool to work at its own rate.
2. Keep bits sharp. Replace as needed.
3. Wear ANSI‑approved safety goggles and
NIOSH‑approved dust mask/respirator while
blowing dust out of motor using compressed air.
4. Eliminate use of extension cord. If an extension
cord is needed, use one with the proper diameter
for its length and load. See Extension Cords
in Grounding section on page 5.