Summary of Contents for Englander BLUE RIDGE 300 P
Page 1
Wood Stove Owner's Manual Part 2 of 2 BLUE RIDGE INSTALLATION AND OPERATION REQUIREMENTS 300 P & L (ESW0007 and ESW0008 models) US Environmental Protection Agency phase II certified wood stove compliant with 2020 cord wood standard Safety tested according to ULC S627, UL 1482 and UL 737 standards by an accredited laboratory.
Page 2
If it can not be provided, the warranty period will be determined by the date of manufacture of the product. It is also highly recommended to register the warranty online at https://www.englander-stoves.com/ca/en/warranty-registration/ Registering the warranty will help to quickly find the information needed on the unit.
7.2 Gasket ..........................32 7.3 Door ..........................32 8. Exploded Diagram and Parts List for the Blue Ridge 300 P (ESW0007) ......35 9. Exploded Diagram and Parts List for the Blue Ridge 300 L (ESW0008) ......38 ENGLANDER LIMITED LIFETIME WARRANTY ................. 40 Installation and Operation Requirements - Blue Ridge 300 P &...
Tested and certified in compliance with CFR 40 part 60, subpart AAA, section 60.534(a)(1(ii) and ASTM E3053. Based on ALT-125 sent by EPA on February 28th, 2018. Carbon monoxide. Page 6 Installation and Operation Requirements - Blue Ridge 300 P & L...
Tested and certified in compliance with CFR 40 part 60, subpart AAA, section 60.534(a)(1(ii) and ASTM E3053. Based on ALT-125 sent by EPA on February 28th, 2018. Installation and Operation Requirements - Blue Ridge 300 P & L Page 7...
For better results, close the air control gradually from the closing of the door to the complete closing of the air control. Page 12 Installation and Operation Requirements - Blue Ridge 300 P & L...
21 ½" (546 mm) The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances above mentioned. Installation and Operation Requirements - Blue Ridge 300 P & L Page 13...
Page 14
48" Flush 48" 36" 122 cm 92 cm Figure 13: Clearances - Top Figure 14: Clearances - Corner 84" 213 cm Figure 15: Clearances - Side Page 14 Installation and Operation Requirements - Blue Ridge 300 P & L...
Page 15
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances above mentioned. Installation and Operation Requirements - Blue Ridge 300 P & L Page 15...
Page 16
21 ½" (549 mm) The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances above mentioned. Page 16 Installation and Operation Requirements - Blue Ridge 300 P & L...
Page 17
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances above mentioned. Installation and Operation Requirements - Blue Ridge 300 P & L Page 17...
Page 18
22 ½" (572 mm) The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances above mentioned. Page 18 Installation and Operation Requirements - Blue Ridge 300 P & L...
Page 19
Les distances de tuyau listées dans ce tableau se réfèrent aux distances obtenues lorsque le poêle est installé en accord avec les dégagements de l’appareil mentionnés ci-dessus. Installation and Operation Requirements - Blue Ridge 300 P & L Page 19...
The floor protection at the back of the stove is limited to the stove’s required clearance if such clearance is smaller than 8 inches (203 mm). Only required under the horizontal section (Ho) of the connector. Must exceed each side of the connector by at least 2 inches (51 mm). Page 20 Installation and Operation Requirements - Blue Ridge 300 P & L...
G) Edge clearance for ceiling shields to side and back walls: 3" (75 mm) Shield extension beyond each side of the appliance: 18" (450 mm) Installation and Operation Requirements - Blue Ridge 300 P & L Page 21...
Page 23
Brick, with a minimum of 24 gauge (0.61 mm) sheet metal backing, spaced out at least 1" (25 mm)* by non-combustible spacers 12" (305 mm) * In Canada this space can be ⅞" (21 mm) Installation and Operation Requirements - Blue Ridge 300 P & L Page 23...
(HVAC type, must meet ULC S110 or UL 181 class 0 or class 1) (B), sold separately. Refer to air intake kit installation instructions for more details. Installation with legs Installation with pedestal Page 24 Installation and Operation Requirements - Blue Ridge 300 P & L...
Lift the fire screen upwards and push the bottom part towards the stove then let the fire screen rest on the bottom of the door opening. Warning: Never leave the stove unattended while in use with the fire screen. Installation and Operation Requirements - Blue Ridge 300 P & L Page 25...
Ensure that the blower’s power cord is not in contact with any surface of the stove to prevent electrical shock or fire damage. Do not run the power cord beneath the stove. Page 26 Installation and Operation Requirements - Blue Ridge 300 P & L...
Put the baffle in place. Repeat steps 1 and 2 for the three other tubes. To remove the tubes use the above steps in reverse order. Installation and Operation Requirements - Blue Ridge 300 P & L Page 27...
Page 28
Note that secondary air tubes (B) can be replaced without removing the baffle board (A) and that all tubes are not necessarely identical (look at the part number on the tube). Page 28 Installation and Operation Requirements - Blue Ridge 300 P & L...
For a stove on legs, install a plate (L) on each leg and screw it in place with the proper hardware (M). For a stove on a pedestal, screw the base on the floor with the proper hardware (O). Page 30 Installation and Operation Requirements - Blue Ridge 300 P & L...
Reinstall the glass, being careful to centre the glass in the door and not to over-tightening the retaining screw. The two main causes of broken door glass are uneven placement in the door and over-tightening the retaining screws. Installation and Operation Requirements - Blue Ridge 300 P & L Page 31...
. Page 32 Installation and Operation Requirements - Blue Ridge 300 P & L...
Page 33
Tighten all door hinge pressure screws when they are at the desired positions. Configurations 1-2-3-4-5-6, show in which direction these act on the adjustment of the door. Installation and Operation Requirements - Blue Ridge 300 P & L Page 33...
Page 34
Tuck any loose fibers under the gasket and into the silicone. Close the door. Do not use the stove for 24 hours. Page 34 Installation and Operation Requirements - Blue Ridge 300 P & L...
8. Exploded Diagram and Parts List for the Blue Ridge 300 P (ESW0007) Installation and Operation Requirements - Blue Ridge 300 P & L Page 35...
Page 36
CERAMIC THERMODISC F110-20F 44085 RHEOSTAT KNOB AC02050 BLOWER ASSEMBLY WITH VARIABLE SPEED CONTROL (UP TO 100 CFM) 60013 POWER CORD 96" X 18-3 type SJT (50 pcs per carton) Page 36 Installation and Operation Requirements - Blue Ridge 300 P & L...
Page 37
Item Description AC01336 5"Ø FRESH AIR INTAKE KIT FOR WOOD STOVE ON PEDESTAL 49028 5" WHITE AIR INTAKE TERMINATION PL65309 DECORATIVE DASH Installation and Operation Requirements - Blue Ridge 300 P & L Page 37...
9. Exploded Diagram and Parts List for the Blue Ridge 300 L (ESW0008) Page 38 Installation and Operation Requirements - Blue Ridge 300 P & L...
Page 39
RHEOSTAT WITHOUT NUT (MODEL KBMS-13BV) AC01211 5"Ø FRESH AIR INTAKE KIT FOR WOOD STOVE ON LEGS 49028 5" WHITE AIR INTAKE TERMINATION AC02055 QUICK CONNECT THERMODISC SE74373 REPLACEMENT lEG Installation and Operation Requirements - Blue Ridge 300 P & L Page 39...
90 days *Subject to limitations above **Picture required Shall your unit or a components be defective, contact immediately your ENGLANDER dealer. To accelerate processing of your warranty claim, make sure to have on hand the following information when calling: •...
Page 41
Installation and Operation Requirements - Blue Ridge 300 P & L Page 41...
Page 42
Resale is strictly prohibited. The manufacturer may update St-Augustin-de-Desmaures (Québec) Canada this document from time to time and cannot be responsible G3A 2H3 for problems, injuries, or damages arising out of the use 1-877-356-6663 of information contained in any document obtained from https://www.englander-stoves.com/ unauthorized sources. tech@sbi-international.com...
Need help?
Do you have a question about the BLUE RIDGE 300 P and is the answer not in the manual?
Questions and answers