Error Code
-SE-
Key short error (10 sec.). Replace assy. control
panel or smart board.
E-11
Sensor open error. Check unplugged sensor, wiring
or smart board. If necessary, replace sensor. If
error code appears when starting sensor function,
replace smart board.
E-12
Sensor short error. Check shorted sensor or smart
board. If necessary, replace sensor. If error code
appears when starting sensor function, replace
smart board.
E-13
Sensor T1 max time error. Check sensor. If neces-
sary, replace sensor. If error code appears when
starting sensor function, replace smart board.
TO TEST BLOWER WINDINGS:
capacitor. 3. Continuity test across the two wires of the run capacitor should be approximately 100 ohms of resistance.
This test allows you to read across all three windings at the same time.
Oven Thermal Cutout
The oven thermal cutout (Cavity TCO) is located on the top side of the oven cavity beside the exhaust duct with a tem-
perature rating of 248°F (120°C) and is NOT resettable.
Hood Thermal Cutout
This cutout will protect the touch control from excessive heat by turning the vent fan on at low speed. If the surface units
of the range are used for long periods of time heat will build up and could damage the microwave control. In order to pre-
vent this, a thermal cutout is installed on the duct behind the control. This cutout will close (158°F/70°C - vent fan ener-
gized) and open (104°F/40°C - vent fan de-energized) depending on temperature.
Magnetron Thermal Cutout
The magnetron thermal cutout is located above the leads to the magnetrons. It is designed to prevent damage to the
magnetron if an overheated condition develops in the tube due to cooling fan failure, obstructed air ducts, dirty or
blocked air intake. Under normal operation, the magnetron thermal cutout remains closed. However, when abnormally
high temperatures are reached within the magnetron, the magnetron thermal cutout will open at 302°F (150°C) causing
the oven to shut down. After the temperature drops to 140°F (60°C) it will reset and cooking will be able to resume.
Bottom Thermal Cutout
During a fire on the stove the heat could be intense enough to close the Hood Thermal Cutout and force the fan to run.
While at moderate high temperature we do want it to run, however during a fire it is advantageous to NOT have the vent
fan running. So if a fire were to start on the stove top the Bottom Thermal Cutout would open at 248°F (120°C) and re-
move all power to the microwave oven. This cutout is NOT resettable.
SMH7185
IMPORTANT SAFETY NOTICE – "For Technicians Only" This service data sheet is
intended for use by persons having electrical, electronic, and mechanical experience
and knowledge at a level generally considered acceptable in the appliance repair trade.
Any attempt to repair a major appliance may result in personal injury and property
damage. The manufacturer or seller cannot be responsible, nor assume any liability for
injury or damage of any kind arising from the use of this data sheet.
http://support-us.samsung.com/spstv/howto.jsp
Cause and countermeasure
1. Disconnect power and remove grill. 2. Open control panel and discharge
Fast Track Troubleshooting
Publication # rsSMH7185 Revision Date 1/20/2012
SE error. Touch switch not available. Order control
assy.
SMH7185BG/XAA
SMH7185WG/XAA
SMH7185STG/XAA
1/20/2012
DE94-01614A
DE94-01614B
DE94-01614C
1

Advertisement

loading

Summary of Contents for Samsung SMH7185BG/XAA

  • Page 1 SUPPORT INFORMATION Training — Plus One http://my.plus1solutions.net/clientPortals/samsung/ Help — GSPN gspn3.samsungcsportal.com Samsung Product Support TV http://support-us.samsung.com/spstv/howto.jsp Customer information videos and chat programs. Programs for Fridges, Laundry, Ranges & D/W Error Code Cause and countermeasure SE error. Touch switch not available. Order control assy.
  • Page 2 SMH7185 1/20/2012...
  • Page 3 Main PCB CN05 Gas Sensor CN401 Door Connector 1 Door sw 3-4 5vdc 3 Door sw 12vdc 5 Gnd 4 Hood TCO 5vdc RY204 Power Low RY05 RY209 Relay Night RY206 RY209 RY208 Relay CN01 Bright RY203 1) KEY OUT-1 Relay high Power...
  • Page 4 Microwave Cooking Wattage Test Temp Rise Output Temp Rise Out- Fill a 1000ml plastic room temperature container with cool tap water, temperature of the water should be 55-65 degrees Stir water with a thermometer and record the water temperature, remove thermometer.

This manual is also suitable for:

Smh7185 /xaa seriesSmh7185stg/xaaSmh7185wg/xaa