Summary of Contents for Carlisle Fluid Technologies TRISK DeVILBISS TRU-CURE IR3L
Page 1
SERVICE MANUAL ORIGINAL LANGUAGE TRU-CURE IR3L/IR3LT TRU-CURE IR3LT TC-IR3L-01 TC-IR3LT-01 TRU-CURE IR3L WITH PYROMETER (904106 FOR USA) (904109 FOR USA) (NORTH AMERICA) (NORTH AMERICA) TRU-CURE IR3LT TRU-CURE IR3L TC-IR3L-02 TC-IR3LT-02 WITH PYROMETER (UNITED KINGDOM) (UNITED KINGDOM) TRU-CURE IR3LT TRU-CURE IR3L TC-IR3L-03 TC-IR3LT-03 WITH PYROMETER...
Page 2
SE 462 28 Vänersborg Sweden declare under our sole responsibility that the products Trisk Devilbiss TRU-CURE IR3L / IR3LT that are used to accelerate the drying of paint, to which this declaration relates, are in conformity with the following standards EN 60335-1:2002...
Page 3
SE 462 28 Vänersborg Sweden declare under our sole responsibility that the products Trisk Devilbiss TRU-CURE IR3L / IR3LT that are used to accelerate the drying of paint, to which this declaration relates, are in conformity with the following standards EN 60335-1:2002...
Page 4
In this part sheet, the words WARNING, CAUTION and NOTE are used to emphasize important safety information as follows: WARNING NOTE CAUTION Hazards or unsafe practices which Hazards or unsafe practices which could result in severe personal Important installation, operation or could result in minor personal injury, injury, death or substantial property maintenance information.
Page 5
TRU CURE IR3L/IR3LT – GENERAL INFORMATION FIELD OF APPLICATION INSTRUCTION TO THE OWNER The Trisk Devilbiss IR3L/IR3LT are designed to provide an The owner of the mobile dryer must produce clear operating accelerated and even cure of most automotive refinishing instructions, adapted to local site conditions and applicable materials.
Page 6
TRU CURE IR3L/IR3LT – OPERATING INSTRUCTIONS IR3L – WITHOUT TEMPERATURE CONTROL FLASH OFF TIMER Turn the main switch on. This will initiate the electronics. Four dots will sequentially blink to indicate the start-up. Next the top display will show 1P (1-phase). The lower FLASH OFF SETTINGS display shows the supply frequency 50 or 60 Hz.
Page 7
TRU CURE IR3L/IR3LT – OPERATING INSTRUCTIONS IR3LT – WITH TEMPERATURE CONTROL FLASH OFF TIMER The mobile dryer is equipped with an automatic temperature control. This enables optimum drying/ curing results within the shortest possible time. FLASH OFF SETTINGS The temperature control (pyrometer) measures the temperature contactless by optics.
MAINTENANCE LAMP REPLACEMENT NOTE Only use original Trisk Devilbiss lamps with the correct power rating. 1. Disconnect power supply. 2. Remove the mesh. 3. Remove the old lamp. 4. Install new lamp in reverse order. CAUTION Do not touch the new lamp with your fingers. Remove the protective paper on the lamp after you have installed it.
SPARE PARTS PICTURE PART NO. DESCRIPTION 410-1000 1 KW IR QUARTS LAMP 991000 for USA 410-1001 REFLECTOR 991001 for USA 410-1002 PROTECTIVE MESH 991002 for USA 410-1003 1 KW CASSETTE COMPLETE 991003 for USA 410-1004 2 KW CASSETTE COMPLETE IR3L 991004 for USA 410-1005 2 KW CASSETTE COMPLETE IR3LT...
This product is covered by Carlisle Fluid Technologies’ materials and workmanship limited warranty. The use of any parts or accessories, from a source other than Carlisle Fluid Technologies, will void all warranties. Failure to reasonably follow any maintenance guidance provided may invalidate any warranty.