Summary of Contents for Carlisle Fluid Technologies TRiSK DeVILBISS TRU-CURE IR3S

  • Page 1 SERVICE MANUAL ORIGINAL LANGUAGE TRU-CURE IR3S TC-IR3S-01 TRU-CURE IR3S (904103 FOR USA) (NORTH AMERICA) TRU-CURE IR3S TC-IR3S-02 (UNITED KINGDOM) TRU-CURE IR3S TC-IR3S-03 (EUROPE) For other languages of this service manual as well as additional product information, please scan the QR code above. SB-81-014-R1 (3/2023) 1 / 11 www.carlisleft.com...
  • Page 2 SE 462 28 Vänersborg Sweden declare under our sole responsibility that the products Trisk Devilbiss TRU-CURE IR3S that are used to accelerate the drying of paint, to which this declaration relates, are in conformity with the following standards EN 60335-1:2002...
  • Page 3 SE 462 28 Vänersborg Sweden declare under our sole responsibility that the products Trisk Devilbiss TRU-CURE IR3S that are used to accelerate the drying of paint, to which this declaration relates, are in conformity with the following standards EN 60335-1:2002...
  • Page 4 In this part sheet, the words WARNING, CAUTION and NOTE are used to emphasize important safety information as follows: WARNING NOTE CAUTION Hazards or unsafe practices which Hazards or unsafe practices which could result in severe personal Important installation, operation or could result in minor personal injury, injury, death or substantial property maintenance information.
  • Page 5 TRU CURE IR3S – GENERAL INFORMATION FIELD OF APPLICATION INSTRUCTION TO THE OWNER The Trisk Devilbiss IR3S are designed to provide an accelerated The owner of the mobile dryer must produce clear operating and even cure of most automotive refinishing materials. instructions, adapted to local site conditions and applicable Typically drying of putty, filler, base and top coats, both national / regional requirements, and make these available to...
  • Page 6 TRU CURE IR3S – OPERATING INSTRUCTIONS IR3S – OPERATIONS Turn the main switch on. This will initiate the electronics. FLASH OFF TIMER Four dots will sequentially blink to indicate the start-up. Next the top display will show 1P (1-phase). The lower display shows the supply frequency 50 or 60 Hz.
  • Page 7: Maintenance

    MAINTENANCE LAMP REPLACEMENT NOTE Only use original Trisk Devilbiss lamps with the correct power rating. 1. Disconnect power supply. 2. Remove the mesh. 3. Remove the old lamp. 4. Install new lamp in reverse order. CAUTION Do not touch the new lamp with your fingers. Remove the protective paper on the lamp after you have installed it.
  • Page 8: Spare Parts

    SPARE PARTS PICTURE PART NO. DESCRIPTION 410-1000 1 KW IR QUARTS LAMP 991000 for USA 410-1001 REFLECTOR 991001 for USA 410-1002 PROTECTIVE MESH 991002 for USA 410-1003 1 KW CASSETTE COMPLETE 991003 for USA 410-1004 2 KW CASSETTE COMPLETE IR3S 991004 for USA 410-1008 CONTROL UNIT COMPLETE IR3S (EU)
  • Page 9: Electrical Diagram

    ELECTRICAL DIAGRAM SB-81-014-R1 (3/2023) 9 / 11 www.carlisleft.com...
  • Page 10 NOTES www.carlisleft.com 10 / 11 SB-81-014-R1 (3/2023)
  • Page 11: Warranty Policy

    This product is covered by Carlisle Fluid Technologies’ materials and workmanship limited warranty. The use of any parts or accessories, from a source other than Carlisle Fluid Technologies, will void all warranties. Failure to reasonably follow any maintenance guidance provided may invalidate any warranty.