Setup; Connecting Additional Hose Lengths - Graco 24M224 Instructions Manual

Hopper or hose heat circulation kit
Table of Contents

Advertisement

Setup

For heating hoppers only:
See fluid schematic on page 9 and parts on page 21.
NOTE: To ensure a leak-proof seal, use PTFE tape
on all pipe thread connections.
1. Connect A and B fluid hoses to shutoff check valve
outlets (H).
2. Connect elbow fitting (17) in pump outlet (3) and
elbow fitting (17) on heater inlet (A) with tubing (16).
3. Connect fitting (7) in the heater fluid outlet (A) and
tee fitting (13) with tubing (4). Connect tee
fitting (13) and fittings (7) in the hopper side ports
with tubing (4).
4. Connect fittings (31) to elbow in bottom outlet of
hoppers and tee fitting (30) with tubing (29). Con-
nect tee fitting (30) and the pump (3) inlet fitting (31)
with tubing (29).
For heating heated hose only:
See fluid schematic on page 13 and parts on page 22.
1. Connect A and B fluid hoses to shutoff check valve
fluid outlets (H).
2. Connect elbow fitting (17) in pump outlet (3) and
elbow fitting (17) on heater inlet (A) with tubing (16).
3. Connect fitting (7) in the heater fluid outlet (A) and
tee fitting (13) with tubing (4).
4. Connect tee fitting (42) and elbow fitting (41) to
recirculation inlets and outlet connections of the
heated hose. See F
. 10.
IG
5. Connect elbow fitting (7) to 1-1/2 gallon tank mani-
fold (23) with tubing (4).
For heating hoppers and heated hose:
See fluid schematic on page 11 and parts on page 20.
1. Connect A and B fluid hoses to shutoff check valve
outlets (H).
2. Connect elbow fitting (17) in pump outlet (3) and
elbow fitting (17) on heater inlet (A) with tubing (16).
313259D
3. Connect fitting (7) in the heater fluid outlet (A) and
4. Connect tee fitting (13) from hose circulation return
5. Connect tee fitting (13) and fittings (7) in the hopper
6. Connect fittings (31) to elbow in bottom outlet of
Hopper Inlet or
1-1/2 gallon tank
manifold
F
IG
Connecting Additional Hose
Lengths
Up to six 50 ft (15.2 m) sections of heated hose can be
attached for a maximum total length of 300 ft (91.4 m).
1. Remove plastic u-turn fittings at the end of the
2. Connect the next length of hose, using union fittings
3. Tubes are color coded. Connect like colors.
To prevent cross-contamination, ensure you connect
"A" side fluid hose to "A" side fluid hose on additional
heated hose.
Get other manuals https://www.bkmanuals.com
tee fitting (13) to hose circulation inlet with
tubing (4).
to tee fitting (13) with tubing (4).
side ports with tubing (4).
hoppers and tee fitting (30) with tubing (29). Con-
nect tee fitting (30) and the pump (3) inlet fitting (31)
with tubing (29).
Blue hose connections
Heater Outlet
Red hose connections
. 10: Recirculation Inlet and Outlet Connections
heated hose assembly.
supplied with the hose.
NOTICE
Installation
ti19230a
17