E-11 Open
E-12 Short
E-13 T1 Max Time Error
E-14 Dry Up / No Load
E-21 Open
E-22 Short
E-23 T1 Max Time Error (Preheating not completed)
E-24 Over temperature error
E-25 Abnormal temperature is sensed at Micro Cook
E-26 Temp is not over the fixed AD in first 3 minutes after heater starts.
E-31 Open (When value of HEX is above "FF" for 5 seconds)
E-32 Short
E-33 The initial value of HEX is under "14" for 30 seconds while a weight
sensor in operation.
E-34 The initial value of K calculated by a weight
sensor is above and under "±28" as value of HEX.
E-35 The value of A is "-" as a weight sensor calculates.
E-36 In case the door opens during sensor cooking.
E-41 Open
E-42 Short
E-43 T1 Max Time Error
E-44 Dry Up
E-45 Cooling Error (3minutes)
E-46 Primary Open Error(3minutes)
E-47 The door opens during cooking
E-51 Open (Sense Failure)
E-53 Read/Write Error
E-54 Zero not to be set
E-61 Open
E-62 Short
E-63 T1 Max Time Error
-SE- Key Short Error (10 seconds)
E-01 Door opens when the door should not be opened.
E-02 Cooking Time Setting Over Error (MWO)
E-03 Cooking Time Setting Over Error (Grill)
E-04 Cooking Time Setting Over Error (Convection)
E-05 Cooking Time Setting Over Error (Combination)
E-06 It fails to sense that the swing heater has stopped for 20 seconds
during cooking.
E-08 In case function of MWO starts with spit inserted into cavity inside.
E-09 The damper is not set to be positioned for 2 minutes.
Fast Track Troubleshooting
IMPORTANT SAFETY NOTICE – "For Technicians Only" This service data sheet is
intended for use by persons having electrical, electronic, and mechanical experience
and knowledge at a level generally considered acceptable in the appliance repair trade.
Any attempt to repair a major appliance may result in personal injury and property
damage. The manufacturer or seller cannot be responsible, nor assume any liability for
injury or damage of any kind arising from the use of this data sheet.
Publication # nwSMH7175 Creation Date 05/9/2012
Samsung 'Microwave' Diagnostic Code Quick Guide
Failure Code
Cause
Error Code Gas Sensor Error Case (E-1X)
Error Code Temp Sensor Error Case (E-2X)
Error Code Gas Sensor Error Case (E-1X)
Error Code Easy/PH Sensor Error Case (E4)
Error Code EEPROM Error Case (E-5X)
Error Code Humidity Sensor Case (E-6X)
Error Code Others (E-0X, Letter)

Advertisement

loading

Summary of Contents for Samsung SMH7175BC/XAA

  • Page 1 SMH7175BE/XAA, SMH7175CC/XAA Publication # nwSMH7175 Creation Date 05/9/2012 SMH7175CE/XAA SMH7175WC/XAA SMH7175WE/XAA Samsung 'Microwave' Diagnostic Code Quick Guide Failure Code Cause E-11 Open E-12 Short Error Code Gas Sensor Error Case (E-1X) E-13 T1 Max Time Error...
  • Page 3 Main PCB CN05 Gas Sensor CN401 Door Connector 3-4 5vdc 1 Door sw 3 Door sw 3-5 12vdc 4-5 5vdc RY204 Power Low RY05 Relay Night RY206 RY209 RY208 Relay RY207 CN01 Bright RY203 Louver 1) KEY OUT-1 Relay Power 2) KEY OUT-2 High Relay 3) KEY OUT-3...
  • Page 4 Microwave Cooking Wattage Test Temp Rise Output Temp Rise Out- Fill a 1000ml plastic room temperature container with cool tap water, temperature of the water should be 55-65 degrees Stir water with a thermometer and record the water temperature, remove thermometer. Place the container in the center of the lowest shelf or center of the bottom of the microwave.

This manual is also suitable for:

Smh7175be/xaaSmh7175cc/xaaNwsmh7175Smh7175ce/xaaSmh7175wc/xaaSmh7175we/xaa