USER'S MANUAL
L
W
®
ON
ORKS
Option Board
SV9000
AF Drive
Subject to changes without notice

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SV9000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Cutler-Hammer SV9000

  • Page 1 USER'S MANUAL ® ORKS Option Board SV9000 AF Drive Subject to changes without notice...
  • Page 2: Table Of Contents

    ® 7. SV9000 LONWORKS INTERFACE ........................ 12 7.1 Network Variables ............................12 7.1.1 Network Input variables in the SV9000 ....................12 7.1.2 Network Output variables from the SV9000..................13 7.1.3 Network Configuration variables to the SV9000................... 15 Echelon, LonTalk, L...
  • Page 3: Introduction

    Encoder input The interface board must be installed in the external option enclosure outside the drive. About this manual The purpose of this manual is to provide you with the information how to install and set up your SV9000 ® ®...
  • Page 4: Specifications

    ® SV9000 Option Board manual Page ORKS _________________________________________________________________________________________ SPECIFICATIONS Bus Interface Channel FTT-10A Free Topology transceiver Transfer cable Twisted pair connections Digital input (4 pcs) I/O -control 24 V ( 15 %), R = 5 k connections Digital output (4 pcs)
  • Page 5: Lonworks

    LonTalk protocol. Interoperable nodes use Standard Network Variable Types (SNVT) for communicating over the network. The definition of ® an SNVT includes units, a range, and an increment. SV9000 L uses only Standard ORKS Network Variable Types as data types.
  • Page 6: Bus Termination

    In a doubly terminated bus topology, two terminations are required, one at each end of the bus. The SV9000 SV9NCLW option board is equipped with termination resistors, which can be selected by jumper X6. If the jumper is in the ‘ST’ position single termination is selected and if it is in ‘DT’ double termination is selected.
  • Page 7: Service Button And Led

    Option Board is located under drive’s cover in normal use, the service button operation can ORKS be done by changing the value of a service button parameter from 0 to 1 or vice versa on the SV9000 operating panel. The location of the service button parameter depends on the used SV9000 application.
  • Page 8: Installation

    Option Board manual Page ORKS _________________________________________________________________________________________ INSTALLATION Before starting the installation, carefully read the safety instructions in the " SV9000 Drive User's ® Manual" chapter “SAFETY”. Check that you have recieved all the L kit parts: Repeater board ORKS ®...
  • Page 9 ® SV9000 Option Board manual Page ORKS _________________________________________________________________________________________ Figure 3-1. Repeater board on mounting board installed on top of the control board _________________________________________________________________________________________ Cutler-Hammer...
  • Page 10: Connections

    ® SV9000 Option Board manual Page ORKS _________________________________________________________________________________________ CONNECTIONS Board layout Terminals: I/O - terminals thermistor input ® network ORKS service power ® Figure 4-1. L option board ORKS Diagnostic LED: power Supply Voltage, Green. Power led is active if the interface board has supply voltage.
  • Page 11: I/O-Control Connections

    Figure 4-1. Control connections NOTE! thermistor input(terminals 327 and 328) must be shorted if not used. READY = ON, when the utility voltage has been applied and the SV9000 is ready to operate = ON, when the motor is running...
  • Page 12: Commissioning

    SV9000 CX Option Board manual Page ORKS _________________________________________________________________________________________ COMMISSIONING First read how to commission the drive in the SV9000 Drive User's Manual (Chapter 8.) ® Commissioning of the L option board: ORKS 1. Check that Fieldbus Application is selected. - Parameter P0.1 = 0 (Fieldbus Appl) 2.
  • Page 13: Sv9000 Lonworks ® Interface

    0 after the fault has been reset. nviMinFreq Defines the minimum frequency for SV9000. If the value is changed via the network it is not saved in the drive’s non-volatile memory, unless bit 0 in nciEeprSave has been set to 1.
  • Page 14: Network Output Variables From The Sv9000

    1 in nciEeprSave has been set to 1. nviAccelTim Defines the acceleration time for SV9000. If the value is changed via the network it is not saved in the drive’s non-volatile memory, unless bit 2 in nciEeprSave has been set to 1.
  • Page 15 Table 6-2 Status word bits nvoActFault This network output variable’s value is the SV9000’s active fault code. If the value is 0 the drive has no fault. See the fault code list in the SV9000 Drive User’s Manual for identifying the faults.
  • Page 16: Network Configuration Variables To The Sv9000

    This network configuration variable is a bit mask, which defines if some of the network input variables are written to SV9000’s non-volatile memory, when changed from network. If a bit is set to 1, the corresponding variable will be saved.
  • Page 17 UD00309...