Advertisement

UNIVERSAL
Hydroponic & Aquaponic
Water Pump
FOR PUMP MODELS
150 - 300
300 - 500
500 - 700
700 - 1000
Please visit www.penningtonaquagarden.com
for helpful hints, tips, how-to videos and spares
www.penningtonaquagarden.com
PenningtonAquagarden
Instrauctions español disponible descargar en: www.youtube.com/user/PenningtonAquagarden

Advertisement

Table of Contents
loading

Summary of Contents for Pennington Aquagarden 150-300

  • Page 1 UNIVERSAL Hydroponic & Aquaponic Water Pump FOR PUMP MODELS 150 - 300 300 - 500 500 - 700 700 - 1000 • • • Please visit www.penningtonaquagarden.com for helpful hints, tips, how-to videos and spares www.penningtonaquagarden.com PenningtonAquagarden Instrauctions español disponible descargar en: www.youtube.com/user/PenningtonAquagarden...
  • Page 2 UNIVERSAL Hydroponic & Aquaponic Water Pump Congratulations on buying your Pennington ® Aquagarden Hydroponic and Aquaponic Water Pump. This pump is designed with advanced technology, to run a wide variety of Hydroponic and Aquaponic set-ups and is suitable for submersible or inline use. The compact powerful motors are easy to maintain having a single moving part impeller system.
  • Page 3: Table Of Contents

    CONTENTS Important safety instructions ............2-3 GETTING TO KNOW YOUR WATER PUMP ....4-5 ........... 4 Parts description and diagram Pump performance ..............5 Technical specifications ...............5 INSTALLATION ..............6-9 Electrical installation ..............6 Locating your water pump ............7 Use of flow control valve & stepped hose tail ......7 Submersible installation ...............8...
  • Page 4: Important Safety Instructions

    FOR INDOOR AND OUTDOOR USE IMPORTANT SAFETY INSTRUCTIONS WARNING - TO REDUCE THE RISK OF ELECTRIC SHOCK, USE ONLY ON PORTABLE SELF-CONTAINED FOUNTAINS NO LARGER THAN 5 FEET IN ANY DIMENSION. WARNING - RISK OF ELECTRIC SHOCK - THIS PUMP IS SUPPLIED WITH A GROUNDING CONDUCTOR AND GROUNDING TYPE ATTACHMENT PLUG.
  • Page 5 CONNECT THE EQUIPMENT INTO AN OUTLET ON A CIRCUIT DIFFERENT FROM THAT TO WHICH THE RECEIVER IS CONNECTED. • CONSULT THE DEALER OR AN EXPERIENCED RADIO/TV TECHNICIAN FOR HELP. SAVE THESE CONSUMER ADVICE CONTACT DETAILS Pennington, 1280 Atlanta Highway, Madison, GA 30650 INSTRUCTIONS Tel: 1-800-285-7333 www.penningtonaquagarden.com...
  • Page 6: Getting To Know Your Water Pump

    GETTING TO KNOW YOUR WATER PUMP Part Description Order Code Part Description Order Code Motor Stepped hose tail x 2 *see below Impeller complete 300: 1058384 150-300, 300-500 500: 1058391 & 500-700: ¾” and 1” 700: 1058407 700-1000: ¾”, 1” and 1¼” 1000: 1058414 GHT adaptor *see below...
  • Page 7: Pump Performance

    GETTING TO KNOW YOUR WATER PUMP PUMP PERFORMANCE FLOW RATE: 10 ft 8 ft 6 ft 21 1 4 ft 2 ft 0 ft 1000 Model 150-300 300-500 500-700 700-1000 TECHNICAL SPECIFICATIONS: Model 150-300 300-500 500-700 700-1000 Cable length 6’ 6’...
  • Page 8: Installation

    INSTALLATION ELECTRICAL SAFETY INFORMATION: Caution: Household indoor and outdoor use. WARNING - Risk of Electric Shock. Mount the unit at a height greater than 1 foot from the ground surface. Install only to covered Class A GFCI receptacle that has a weatherproof enclosure with the attachment plug cap inserted or removed.
  • Page 9: Locating Your Water Pump

    INSTALLATION GROUNDING INSTRUCTIONS – This appliance must be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. The appliance is equipped with a cord having an appliance grounding conductor and a grounding plug.
  • Page 10: Submersible Installation

    INSTALLATION SUBMERSIBLE USE: ½” hose tail Stepped hose tail adaptor O ring Pre-filter intake cage with optional pre-filter foam Flow control valve O ring O ring Low water intake adaptor with pre-filter foam...
  • Page 11: Inline Installation

    INSTALLATION INLINE USE: IMPORTANT: It is recommended to ½” hose tail install a ball valve in front of the inlet hose tail if the pump is Stepped installed inline – this hose tail can be shut-off in case of pump maintenance. adaptor IMPORTANT: When being used...
  • Page 12: Maintenance

    WARNING - Failure to carry out routine maintenance leaving the pump under reduced or no flow conditions for long periods will result in a short- er pump life and invalidate the guarantee. Pennington Aquagarden Water Pumps are centrifugal pumps with a magnetic impeller ®...
  • Page 13: Monthly Maintenance

    MAINTENANCE MONTHLY MAINTENANCE Carry out routine maintenance (steps 1 and 2), then follow steps 3 and 4 below. STEP 3: Remove the impeller cover by turning it counter-clockwise to release the lock, then pull away from the pump motor (remove the impeller cover locking screw if it is in use prior to turning the cover).
  • Page 14: Troubleshooting

    TROUBLESHOOTING PROBLEM Low flow from pump Follow routine cleaning procedure if no improvement. Follow monthly cleaning procedure. Ensure pipe work is not blocked or leaking or is laid so that it gets crushed or kinked. Keep the height that water is to be pumped from the water surface (called head) to a minimum.
  • Page 15: Consumer Advice Contact Details

    CONSUMER ADVICE CONTACT DETAILS Pennington, 1280 Atlanta Highway, Madison, GA 30650 Tel: 1-800-285-7333 www.penningtonaquagarden.com Pennington with design is a registered trademark of Pennington Seed, Inc. PUMP...
  • Page 16: Guarantee

    GUARANTEE This product is guaranteed against defects in material and workmanship for 2 years from the date of purchase, under normal usage. The guarantee DOES NOT APPLY in case of improper use, negligence, lack of maintenance or accidental damage to the pump. If the pump fails due to a manufacturing fault within this period it will be either repaired or replaced free of charge.