Ventilation; Connecting The Appliance; Water Connection; Electrical Connection - Bosch B11CB81SSS/01 Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

en-us

Ventilation

The air on the rear panel and on the side panels of
the appliance heats up. Conduction of the heated air
must not be obstructed. Otherwise the refrigeration unit
must work harder. This increases power consumption.
Therefore: Never cover or block ventilation openings!

Connecting the appliance

After installing the appliance, wait at least 8 hours until
the appliance is switched on. During transportation
the oil in the compressor may have flowed into
the refrigeration system.
,
CAUTION:
Always connect the water before the power.
Before switching on the appliance for the first time,
clean the interior of the appliance (see chapter
Cleaning the appliance).

Water connection

The water may be connected only by a competent
plumber according to the local regulations of
the appropriate water supply company.
,
WARNING:
Connect the appliance to a drinking water line
only!
Minimum pressure: 29 psi (2 bar)
Maximum pressure: 116 psi (8 bar)
Pressure over 116 psi (8 bar): install a pressure
limiter between drinking water connection and hose
set
A cold water connection is necessary for operating the
automatic ice maker.
Install a separate shut-off valve in the cold water supply
line.
The shut-off valve should not be located behind the
appliance. It is recommended that you mount the shut-
off valve directly next to the appliance or at another
place which is easily accessible.
6

Electrical connection

,
WARNING:
Avoid the risk of an electric shock!
,
WARNING:
Insert into a grounded 3-phase socket. Never
remove grounding phase. Do not use any
adapters. Do not use any extension cables.
,
WARNING:
Non-compliance with these instructions may
result in death, fire or an electric shock.
Improper connection of the protective conductor
may result in an electric shock. If you are in
doubt whether the appliance has been grounded
properly, have the appliance tested by
a qualified electrician or service technician.
Do not use extension cables or distributors. This
appliance must be connected to a permanently
installed socket.
The socket must be near the appliance and also freely
accessible following installation of the appliance.
The appliance complies with protection class I.
Connect the appliance to 115 V/60 Hz alternating
current via a correctly installed socket with protective
conductor. The socket must be fused with a 10 to 16 A
fuse.
The appliance comes with a UL registered 3-wire power
cord. The appliance requires a 3-pole socket.
Please observe the following table with regard to this:
Appliance
Maximum simulta-
neous load
Fridge-
6.0 amps
freezer
Check on the rating plate whether the indicated voltage
and current type correspond with the values of your
power supply. The location of the rating plate can be
found in the chapter entitled Customer service.
,
WARNING:
Never connect the appliance to electronic
energy saver plugs.
Our appliances can be used with mains and
sine-controlled inverters. Mains-controlled
inverters are used for photovoltaic systems
which are connected directly to the national grid.
Sine-controlled inverters must be used for
isolated applications (e.g. on ships or
in mountain lodges) which are not connected
directly to the national grid.

Advertisement

Table of Contents
loading

This manual is also suitable for:

B1 cb seriesB11cb81sssBorectwodwrh151

Table of Contents