Series Operation

Floating voltages must not exceed 240 Vdc. No output terminal may be more than 240 V from chassis
ground.
Figure 4-8 shows how power supplies can be connected in series for higher voltage output. Series connections are
straightforward in this case.
Program each power supply independently. If two supplies are used in the series configuration, program each supply for
50% of the total output voltage. Set the current limit of each supply to the maximum that the load can handle without
damage.
Each power supply has a reverse voltage protection diode across its output. If a reverse voltage is
applied, the supply cannot control the current conducted through this diode. To avoid damaging the
supply, never connect it in such a way that a reverse voltage can force it to conduct current in excess of
the supply's maximum reverse diode current (see "Supplemental Characteristics").

External Voltage Control

The setup shown in Figure 4-9 allows an external dc voltage to program the power supply output. A voltage applied to the
voltage programming input programs the output voltage and a voltage applied to the current programming input programs
the output current. See Figure 4-3 and Table 4-1 for an explanation of these programming input connections.

Programming Series 654xA and 655xA Supplies

Wiring Considerations
The input impedance of the analog input is 10 kΩ. If the output impedance of your programming source is not negligible
with this, programming errors will result. Larger output impedances result in proportionally greater errors.
Be careful of capacitive coupling from the programming inputs to other lines wired to the analog connector. Such coupling
can cause output oscillations. You can minimize coupling by bundling the IP, VP, and Common P lines and keeping them
separated from other wires. Twisting these three lines together is also recommended.