When the sensor receives the second induction signals within the first induction, it will
•
restart to time from the moment.
•
Turn LUX knob anti-clockwise on the minimum (3). If the ambient light is less than 3LUX
(darkness), the inductor load could work when it receives induction signal.
Note: When testing in daylight, please turn LUX knob to the
sensor may not work!
Notes
Installation must be undertaken by a licensed Electrician.
•
Cannot be installed on uneven and shaky surface.
•
In front of the sensor, ensure that there is no obstructive object/s affecting the detection.
•
•
Avoid installing it near metal and glass which may affect the sensor.
•
For your safety, please do not open the cover if you find a problem after installation.
In order to avoid the unexpected damage of product, please add a safe device of current 6A when
•
installing microwave sensor, for example, fuse, safe tube etc.
Troubleshooting
•
The load does not work:
a. Check the power and the load.
b. Does the indicator light turn on after sensing? If yes, please check load.
c. If the indicator light is not on after sensing, please check if the working light
corresponds to the ambient light.
d. Please check if the working voltage corresponds to the power source.
•
The sensitivity is poor:
a. Please check that the front of the sensor has no obstructive object/s that may affect
receiving of signals.
b. Please check if the signal source is in the detection fields.
c. Please check the installation height (2-6m).
•
The sensor will not automatically turn off the load:
a. Check if there are continual signals in the detection fields.
b. Check if the time delay is set to the longest.
c. Check if the power corresponds to the instruction.
1800 909 306